Boilers

This is the current list of supported boilers from brands like Buderus, Nefit, Sieger, Junkers and Bosch:

  • BK13, BK15
  • GB125, GB135, GB1x2i, GB162, GBx72, GB212, GB162, GB192, GB122, GB192i.2
  • MC10
  • Cascade CM10, MC400
  • Logano
  • Logamax Plus GB022, U122
  • Logamatic MC10, MC110
  • Condens 2500, GC9000
  • Bosch/Junkers Cerapur GC2200W
  • Logomatic
  • Bosch/Junkers Cerapur Top, Aero
  • Bosch/Junkers Cerapur ZSB 14-3 A
  • Greenstar Si, 30Ri Compact, ErP, HIU, 8000
  • Nefit Topline, Trendline
  • Cascade MCM10
  • Nefit Proline
  • Nefit Smartline
  • GC7000F, GC700iW, GC9800IW
  • KB195i
  • Hybrid Heatpump
  • Enviline
  • Compress 6000AW
  • Hybrid 3000-7000iAW
  • SupraEco
  • WLW196i, WSW196i
  • Condens 2300, 5000i
  • Ecomline Excellent
  • EasyControl Adapter

Device Entities with Commands

info

The boiler commands below will vary depending on boiler type/brand and system configuration Some commands will not work because they are overwritten by controller or thermostat. In this case there are thermostat commands for this setting.

:::warning this list is not complete and subject to change between versions. :::

commanddataidcomments
comfort<hot |eco | intelligent>
flowtemp<degrees>Limited to heatingtemp, set by thermostat if present
dhw.settemp<degrees>Only if thermostat does not manage it
boilhyston<degrees>Start burner below flowtemp (negative value), allowed range depends on boiler type
boilhystoff<degrees>Stop burner above flowtemp (positive value), allowed range depends on boiler type
burnperiod<minutes>
burnminpower<%>Changeable only for modulated burners
burnmaxpower<%>Changeable only for modulated burners
pumpdelay<minutes>
dhw.activated<off | on>
dhw.tapactivated<off | on>Special function working in boiler test-mode
dhw.onetime<off | on>Overwritten by some thermostats, see thermostat commands
dhw.circpump<off | on>
dhw.circ<off | on>Overwritten by some thermostats, see thermostat commands
dhw.circmode<n>(1=1x3min, .. 6=6x3min, 7=on)
dhw.flowtempoffset<degrees>Offset to boiler temperature while preparing warm water
dhw.maxpower<%>Maximum power for warm water heating
heatingactivated<off | on>Not changeable for some systems. i.g. Set by MC10 rotary control
heatingtemp<degrees>Upper limit for flowtemp, not changeable for some systems or overwritten (MC10)
maintenance<off | <hours> | <dd.mm.yyyy> | reset>set maintenance to date or time or reset message
pumpmodmin<%>Changeable only for modulated pumps
pumpmodmax<%>Changeable only for modulated pumps
reset<error | maintenance>Use reset error only if there is an active error!