All Devices and Entities~

This page contains a comprehensive list of all devices and entities supported by EMS-ESP.

Download the full CSV file

device name device type product id shortname fullname type [options...] | (min/max) uom writeable discovery entityid v3.4 discovery entityid modbus unit identifier modbus block modbus scale factor modbus offset modbus count
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.nrg energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrg 5 9 1/100 0 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat 5 0 1/100 85 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgcool energy cooling uint24 (>=0<=167772) kWh False sensor.boiler_energy_cooling sensor.boiler_nrgcool 5 0 1/100 87 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal 5 0 1/100 89 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp 5 0 1/100 91 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat 5 0 1/100 93 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/100 95 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 metercool meter cooling uint24 (>=0<=167772) kWh False sensor.boiler_meter_cooling sensor.boiler_metercool 5 0 1/100 97 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.meter meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/100 2 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal 5 0 1/60 99 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol 5 0 1/60 101 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating 5 0 1/60 103 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling 5 0 1/60 105 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.uptimecomp operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecomp 5 9 1/60 4 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool 5 0 1/60 107 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 totalcompstarts total compressor control starts uint24 (>=0<=16777214) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts 5 0 1 109 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatingstarts heating control starts uint24 (>=0<=16777214) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts 5 0 1 111 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 coolingstarts cooling control starts uint24 (>=0<=16777214) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts 5 0 1 113 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.startshp starts hp uint24 (>=0<=16777214) False sensor.boiler_dhw_starts_hp sensor.boiler_dhw_startshp 5 9 1 6 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 poolstarts pool control starts uint24 (>=0<=16777214) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts 5 0 1 115 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgconstotal total energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal 5 0 1 117 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal 5 0 1 119 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating 5 0 1 121 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.nrgconscomp energy consumption compressor uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscomp 5 9 1 8 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling 5 0 1 123 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool 5 0 1 125 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal 5 0 1 127 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777214) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating 5 0 1 129 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.auxelecheatnrgcons aux elec. heater energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgcons 5 9 1 10 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777214) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool 5 0 1 131 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgsupptotal total energy supplied uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal 5 0 1 133 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgsuppheating total energy supplied heating uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating 5 0 1 135 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.nrgsupp total energy warm supplied uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsupp 5 9 1 12 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling 5 0 1 137 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 nrgsupppool total energy supplied pool uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool 5 0 1 139 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hppower compressor power output uint16 (>=0<=3199) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower 5 0 1/10 141 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower 5 0 1 142 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pvmaxcomp pv compressor max power uint8 (>=0<=25) kW True number.boiler_pv_compressor_max_power number.boiler_pvmaxcomp 5 0 1/10 143 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 powerreduction power reduction uint8 (>=30<=60) % True number.boiler_power_reduction number.boiler_powerreduction 5 0 10 144 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpsetdiffpress set differential pressure uint8 (>=150<=750) mbar True number.boiler_set_differential_pressure number.boiler_hpsetdiffpress 5 0 50 145 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon 5 0 1 146 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpactivity compressor activity enum [off|heating|cooling|hot water|pool|pool heating|defrost|compressor alarm] False sensor.boiler_compressor_activity sensor.boiler_hpactivity 5 0 1 147 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd 5 0 1 148 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve 5 0 1 149 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd 5 0 1 150 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd 5 0 1 151 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein 5 0 1/10 152 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout 5 0 1/10 153 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0 5 0 1/10 154 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1 5 0 1/10 155 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3 5 0 1/10 156 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1 5 0 1/10 157 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3 5 0 1/10 158 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4 5 0 1/10 159 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5 5 0 1/10 160 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6 5 0 1/10 161 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7 5 0 1/10 162 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2 5 0 1/10 163 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1 5 0 1/10 164 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1 5 0 1/10 165 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4 5 0 1/10 166 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1 5 0 1/10 167 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp 5 0 1/2 168 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way 5 0 1 169 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin1 input 1 state boolean False binary_sensor.boiler_input_1_state binary_sensor.boiler_hpin1 5 0 1 170 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt 5 0 1 171 8
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin2 input 2 state boolean False binary_sensor.boiler_input_2_state binary_sensor.boiler_hpin2 5 0 1 179 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt 5 0 1 180 8
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin3 input 3 state boolean False binary_sensor.boiler_input_3_state binary_sensor.boiler_hpin3 5 0 1 188 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt 5 0 1 189 8
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin4 input 4 state boolean False binary_sensor.boiler_input_4_state binary_sensor.boiler_hpin4 5 0 1 197 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt 5 0 1 198 8
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 maxheatcomp heat limit compressor enum [0 kW|3 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp 5 0 1 206 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 maxheatheat heat limit heating enum [3 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat 5 0 1 207 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.maxheat heat limit enum [3 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheat 5 9 1 14 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheatersource aux heater source enum [not installed|electric heater|exclusive|parallel|hybrid] True select.boiler_aux_heater_source select.boiler_auxheatersource 5 0 1 208 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling 5 0 1 209 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly 5 0 1 210 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff 5 0 1 211 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheaterstatus aux heater status enum [off|heating|cooling|hot water|pool|pool heating|defrost|compressor alarm] False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus 5 0 1 212 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheaterlevel aux heater level uint8 (>=0<=100) % False sensor.boiler_aux_heater_level sensor.boiler_auxheaterlevel 5 0 1 213 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay 5 0 10 214 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit 5 0 1/10 215 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart 5 0 1/10 216 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode 5 0 1 217 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat 5 0 5 218 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool 5 0 5 219 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool 5 0 5 220 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode 5 0 1 221 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom 5 0 15 222 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto 5 0 15 223 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent 5 0 1 224 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode 5 0 1 225 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix 5 0 1 226 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat 5 0 1/10 227 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool 5 0 1/10 228 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling 5 0 1 229 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable 5 0 1 230 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve 5 0 1 231 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump 5 0 1 232 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod 5 0 1 233 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way 5 0 1 234 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1 5 0 1 235 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2 5 0 1 236 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3 5 0 1 237 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0 5 0 1 238 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode 5 0 1 239 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan 5 0 1 240 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 shutdown shutdown cmd [off|on] True sensor.boiler_shutdown sensor.boiler_shutdown 5 0 1 241 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hpcurrpower compressor current power uint16 (>=0<=31999) W False sensor.boiler_compressor_current_power sensor.boiler_hpcurrpower 5 0 1 242 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 hppowerlimit power limit uint16 (>=0<=31999) W True number.boiler_power_limit number.boiler_hppowerlimit 5 0 1 243 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop 5 9 1 15 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat 5 9 1 16 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.altopprio prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altopprio 5 9 1 17 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff 5 9 1 18 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff 5 9 1 19 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff 5 9 1 20 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.comfdiff comfort diff uint8 (>=4<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff 5 9 1 21 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.ecodiff eco diff uint8 (>=4<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff 5 9 1 22 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff 5 9 1 23 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop 5 9 1 24 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop 5 9 1 25 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop 5 9 1 26 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.hpcircpump circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpump 5 9 1 27 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
CS5800i, CS6800i, WLW176i, WLW186i boiler 8 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Greenstar 2000 boiler 11 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Greenstar 2000 boiler 11 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Greenstar 2000 boiler 11 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Greenstar 2000 boiler 11 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Greenstar 2000 boiler 11 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Greenstar 2000 boiler 11 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Greenstar 2000 boiler 11 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Greenstar 2000 boiler 11 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Greenstar 2000 boiler 11 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Greenstar 2000 boiler 11 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Greenstar 2000 boiler 11 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Greenstar 2000 boiler 11 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Greenstar 2000 boiler 11 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Greenstar 2000 boiler 11 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Greenstar 2000 boiler 11 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Greenstar 2000 boiler 11 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Greenstar 2000 boiler 11 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Greenstar 2000 boiler 11 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Greenstar 2000 boiler 11 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Greenstar 2000 boiler 11 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Greenstar 2000 boiler 11 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Greenstar 2000 boiler 11 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Greenstar 2000 boiler 11 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Greenstar 2000 boiler 11 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Greenstar 2000 boiler 11 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Greenstar 2000 boiler 11 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Greenstar 2000 boiler 11 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Greenstar 2000 boiler 11 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Greenstar 2000 boiler 11 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Greenstar 2000 boiler 11 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Greenstar 2000 boiler 11 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Greenstar 2000 boiler 11 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Greenstar 2000 boiler 11 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Greenstar 2000 boiler 11 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Greenstar 2000 boiler 11 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Greenstar 2000 boiler 11 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Greenstar 2000 boiler 11 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Greenstar 2000 boiler 11 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Greenstar 2000 boiler 11 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Greenstar 2000 boiler 11 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Greenstar 2000 boiler 11 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Greenstar 2000 boiler 11 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Greenstar 2000 boiler 11 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Greenstar 2000 boiler 11 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Greenstar 2000 boiler 11 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Greenstar 2000 boiler 11 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Greenstar 2000 boiler 11 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Greenstar 2000 boiler 11 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Greenstar 2000 boiler 11 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Greenstar 2000 boiler 11 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Greenstar 2000 boiler 11 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Greenstar 2000 boiler 11 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Greenstar 2000 boiler 11 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Greenstar 2000 boiler 11 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Greenstar 2000 boiler 11 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Greenstar 2000 boiler 11 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Greenstar 2000 boiler 11 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Greenstar 2000 boiler 11 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Greenstar 2000 boiler 11 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Greenstar 2000 boiler 11 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Greenstar 2000 boiler 11 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Greenstar 2000 boiler 11 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Greenstar 2000 boiler 11 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Greenstar 2000 boiler 11 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Greenstar 2000 boiler 11 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Greenstar 2000 boiler 11 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Greenstar 2000 boiler 11 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Greenstar 2000 boiler 11 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Greenstar 2000 boiler 11 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Greenstar 2000 boiler 11 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Greenstar 2000 boiler 11 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Greenstar 2000 boiler 11 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Greenstar 2000 boiler 11 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Greenstar 2000 boiler 11 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Greenstar 2000 boiler 11 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Greenstar 2000 boiler 11 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Greenstar 2000 boiler 11 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Greenstar 2000 boiler 11 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Greenstar 2000 boiler 11 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Greenstar 2000 boiler 11 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Greenstar 2000 boiler 11 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Greenstar 2000 boiler 11 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Greenstar 2000 boiler 11 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Greenstar 2000 boiler 11 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Greenstar 2000 boiler 11 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Greenstar 2000 boiler 11 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Greenstar 2000 boiler 11 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Greenstar 2000 boiler 11 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Greenstar 2000 boiler 11 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Greenstar 2000 boiler 11 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Greenstar 2000 boiler 11 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Greenstar 2000 boiler 11 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Greenstar 2000 boiler 11 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Greenstar 2000 boiler 11 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Greenstar 2000 boiler 11 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Greenstar 2000 boiler 11 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Greenstar 2000 boiler 11 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Greenstar 2000 boiler 11 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Greenstar 2000 boiler 11 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Greenstar 2000 boiler 11 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Greenstar 2000 boiler 11 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Greenstar 2000 boiler 11 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Greenstar 2000 boiler 11 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Greenstar 2000 boiler 11 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Greenstar 2000 boiler 11 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Greenstar 2000 boiler 11 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Greenstar 2000 boiler 11 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Greenstar 2000 boiler 11 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Greenstar 2000 boiler 11 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Greenstar 2000 boiler 11 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Greenstar 2000 boiler 11 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Greenstar 2000 boiler 11 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Greenstar 2000 boiler 11 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Greenstar 2000 boiler 11 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Greenstar 2000 boiler 11 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
C1200W boiler 12 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
C1200W boiler 12 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
C1200W boiler 12 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
C1200W boiler 12 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
C1200W boiler 12 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
C1200W boiler 12 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
C1200W boiler 12 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
C1200W boiler 12 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
C1200W boiler 12 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
C1200W boiler 12 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
C1200W boiler 12 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
C1200W boiler 12 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
C1200W boiler 12 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
C1200W boiler 12 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
C1200W boiler 12 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
C1200W boiler 12 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
C1200W boiler 12 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
C1200W boiler 12 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
C1200W boiler 12 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
C1200W boiler 12 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
C1200W boiler 12 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
C1200W boiler 12 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
C1200W boiler 12 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
C1200W boiler 12 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
C1200W boiler 12 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
C1200W boiler 12 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
C1200W boiler 12 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
C1200W boiler 12 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
C1200W boiler 12 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
C1200W boiler 12 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
C1200W boiler 12 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
C1200W boiler 12 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
C1200W boiler 12 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
C1200W boiler 12 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
C1200W boiler 12 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
C1200W boiler 12 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
C1200W boiler 12 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
C1200W boiler 12 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
C1200W boiler 12 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
C1200W boiler 12 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
C1200W boiler 12 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
C1200W boiler 12 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
C1200W boiler 12 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
C1200W boiler 12 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
C1200W boiler 12 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
C1200W boiler 12 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
C1200W boiler 12 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
C1200W boiler 12 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
C1200W boiler 12 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
C1200W boiler 12 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
C1200W boiler 12 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
C1200W boiler 12 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
C1200W boiler 12 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
C1200W boiler 12 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
C1200W boiler 12 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
C1200W boiler 12 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
C1200W boiler 12 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
C1200W boiler 12 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
C1200W boiler 12 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
C1200W boiler 12 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
C1200W boiler 12 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
C1200W boiler 12 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
C1200W boiler 12 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
C1200W boiler 12 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
C1200W boiler 12 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
C1200W boiler 12 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
C1200W boiler 12 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
C1200W boiler 12 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
C1200W boiler 12 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
C1200W boiler 12 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
C1200W boiler 12 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
C1200W boiler 12 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
C1200W boiler 12 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
C1200W boiler 12 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
C1200W boiler 12 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
C1200W boiler 12 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
C1200W boiler 12 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
C1200W boiler 12 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
C1200W boiler 12 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
C1200W boiler 12 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
C1200W boiler 12 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
C1200W boiler 12 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
C1200W boiler 12 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
C1200W boiler 12 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
C1200W boiler 12 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
C1200W boiler 12 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
C1200W boiler 12 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
C1200W boiler 12 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
C1200W boiler 12 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
C1200W boiler 12 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
C1200W boiler 12 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
C1200W boiler 12 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
C1200W boiler 12 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
C1200W boiler 12 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
C1200W boiler 12 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
C1200W boiler 12 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
C1200W boiler 12 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
C1200W boiler 12 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
C1200W boiler 12 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
C1200W boiler 12 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
C1200W boiler 12 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
C1200W boiler 12 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
C1200W boiler 12 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
C1200W boiler 12 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
C1200W boiler 12 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
C1200W boiler 12 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
C1200W boiler 12 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
C1200W boiler 12 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
C1200W boiler 12 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
C1200W boiler 12 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
C1200W boiler 12 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
C1200W boiler 12 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
C1200W boiler 12 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
C1200W boiler 12 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
C1200W boiler 12 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
CS5800iG boiler 16 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
CS5800iG boiler 16 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
CS5800iG boiler 16 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
CS5800iG boiler 16 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
CS5800iG boiler 16 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
CS5800iG boiler 16 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
CS5800iG boiler 16 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
CS5800iG boiler 16 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
CS5800iG boiler 16 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
CS5800iG boiler 16 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
CS5800iG boiler 16 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
CS5800iG boiler 16 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
CS5800iG boiler 16 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
CS5800iG boiler 16 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
CS5800iG boiler 16 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
CS5800iG boiler 16 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
CS5800iG boiler 16 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
CS5800iG boiler 16 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
CS5800iG boiler 16 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
CS5800iG boiler 16 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
CS5800iG boiler 16 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
CS5800iG boiler 16 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
CS5800iG boiler 16 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
CS5800iG boiler 16 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
CS5800iG boiler 16 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
CS5800iG boiler 16 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
CS5800iG boiler 16 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
CS5800iG boiler 16 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
CS5800iG boiler 16 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
CS5800iG boiler 16 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
CS5800iG boiler 16 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
CS5800iG boiler 16 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
CS5800iG boiler 16 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
CS5800iG boiler 16 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
CS5800iG boiler 16 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
CS5800iG boiler 16 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
CS5800iG boiler 16 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
CS5800iG boiler 16 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
CS5800iG boiler 16 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
CS5800iG boiler 16 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
CS5800iG boiler 16 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
CS5800iG boiler 16 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
CS5800iG boiler 16 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
CS5800iG boiler 16 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
CS5800iG boiler 16 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
CS5800iG boiler 16 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
CS5800iG boiler 16 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
CS5800iG boiler 16 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
CS5800iG boiler 16 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
CS5800iG boiler 16 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
CS5800iG boiler 16 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
CS5800iG boiler 16 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
CS5800iG boiler 16 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
CS5800iG boiler 16 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
CS5800iG boiler 16 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
CS5800iG boiler 16 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
CS5800iG boiler 16 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
CS5800iG boiler 16 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
CS5800iG boiler 16 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
CS5800iG boiler 16 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
CS5800iG boiler 16 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
CS5800iG boiler 16 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
CS5800iG boiler 16 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
CS5800iG boiler 16 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
CS5800iG boiler 16 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
CS5800iG boiler 16 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
CS5800iG boiler 16 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
CS5800iG boiler 16 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
CS5800iG boiler 16 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
CS5800iG boiler 16 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
CS5800iG boiler 16 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
CS5800iG boiler 16 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
CS5800iG boiler 16 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
CS5800iG boiler 16 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
CS5800iG boiler 16 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
CS5800iG boiler 16 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
CS5800iG boiler 16 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
CS5800iG boiler 16 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
CS5800iG boiler 16 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
CS5800iG boiler 16 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
CS5800iG boiler 16 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
CS5800iG boiler 16 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
CS5800iG boiler 16 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
CS5800iG boiler 16 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
CS5800iG boiler 16 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
CS5800iG boiler 16 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
CS5800iG boiler 16 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
CS5800iG boiler 16 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
CS5800iG boiler 16 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
CS5800iG boiler 16 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
CS5800iG boiler 16 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
CS5800iG boiler 16 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
CS5800iG boiler 16 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
CS5800iG boiler 16 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
CS5800iG boiler 16 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
CS5800iG boiler 16 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
CS5800iG boiler 16 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
CS5800iG boiler 16 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
CS5800iG boiler 16 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
CS5800iG boiler 16 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
CS5800iG boiler 16 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
CS5800iG boiler 16 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
CS5800iG boiler 16 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
CS5800iG boiler 16 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
CS5800iG boiler 16 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
CS5800iG boiler 16 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
CS5800iG boiler 16 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
CS5800iG boiler 16 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
CS5800iG boiler 16 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
CS5800iG boiler 16 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
CS5800iG boiler 16 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
CS5800iG boiler 16 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
CS5800iG boiler 16 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
CS5800iG boiler 16 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
CS5800iG boiler 16 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
BK13/BK15, Smartline, GB1*2 boiler 64 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
BK13/BK15, Smartline, GB1*2 boiler 64 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
BK13/BK15, Smartline, GB1*2 boiler 64 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
BK13/BK15, Smartline, GB1*2 boiler 64 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
BK13/BK15, Smartline, GB1*2 boiler 64 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
BK13/BK15, Smartline, GB1*2 boiler 64 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
BK13/BK15, Smartline, GB1*2 boiler 64 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
BK13/BK15, Smartline, GB1*2 boiler 64 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
BK13/BK15, Smartline, GB1*2 boiler 64 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
BK13/BK15, Smartline, GB1*2 boiler 64 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
BK13/BK15, Smartline, GB1*2 boiler 64 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
BK13/BK15, Smartline, GB1*2 boiler 64 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
BK13/BK15, Smartline, GB1*2 boiler 64 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
BK13/BK15, Smartline, GB1*2 boiler 64 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
BK13/BK15, Smartline, GB1*2 boiler 64 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
BK13/BK15, Smartline, GB1*2 boiler 64 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
BK13/BK15, Smartline, GB1*2 boiler 64 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
BK13/BK15, Smartline, GB1*2 boiler 64 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
BK13/BK15, Smartline, GB1*2 boiler 64 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
BK13/BK15, Smartline, GB1*2 boiler 64 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
BK13/BK15, Smartline, GB1*2 boiler 64 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
BK13/BK15, Smartline, GB1*2 boiler 64 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
BK13/BK15, Smartline, GB1*2 boiler 64 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
BK13/BK15, Smartline, GB1*2 boiler 64 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
BK13/BK15, Smartline, GB1*2 boiler 64 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
BK13/BK15, Smartline, GB1*2 boiler 64 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
BK13/BK15, Smartline, GB1*2 boiler 64 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
BK13/BK15, Smartline, GB1*2 boiler 64 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
BK13/BK15, Smartline, GB1*2 boiler 64 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
BK13/BK15, Smartline, GB1*2 boiler 64 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
BK13/BK15, Smartline, GB1*2 boiler 64 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
BK13/BK15, Smartline, GB1*2 boiler 64 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
BK13/BK15, Smartline, GB1*2 boiler 64 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
BK13/BK15, Smartline, GB1*2 boiler 64 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
BK13/BK15, Smartline, GB1*2 boiler 64 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
BK13/BK15, Smartline, GB1*2 boiler 64 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
BK13/BK15, Smartline, GB1*2 boiler 64 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
BK13/BK15, Smartline, GB1*2 boiler 64 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
BK13/BK15, Smartline, GB1*2 boiler 64 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
BK13/BK15, Smartline, GB1*2 boiler 64 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
BK13/BK15, Smartline, GB1*2 boiler 64 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
BK13/BK15, Smartline, GB1*2 boiler 64 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
BK13/BK15, Smartline, GB1*2 boiler 64 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
BK13/BK15, Smartline, GB1*2 boiler 64 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
BK13/BK15, Smartline, GB1*2 boiler 64 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
BK13/BK15, Smartline, GB1*2 boiler 64 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
BK13/BK15, Smartline, GB1*2 boiler 64 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
BK13/BK15, Smartline, GB1*2 boiler 64 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
BK13/BK15, Smartline, GB1*2 boiler 64 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
BK13/BK15, Smartline, GB1*2 boiler 64 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
BK13/BK15, Smartline, GB1*2 boiler 64 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
BK13/BK15, Smartline, GB1*2 boiler 64 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
BK13/BK15, Smartline, GB1*2 boiler 64 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
BK13/BK15, Smartline, GB1*2 boiler 64 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
BK13/BK15, Smartline, GB1*2 boiler 64 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
BK13/BK15, Smartline, GB1*2 boiler 64 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
BK13/BK15, Smartline, GB1*2 boiler 64 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
BK13/BK15, Smartline, GB1*2 boiler 64 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
BK13/BK15, Smartline, GB1*2 boiler 64 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
BK13/BK15, Smartline, GB1*2 boiler 64 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
BK13/BK15, Smartline, GB1*2 boiler 64 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
BK13/BK15, Smartline, GB1*2 boiler 64 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
BK13/BK15, Smartline, GB1*2 boiler 64 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
BK13/BK15, Smartline, GB1*2 boiler 64 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
BK13/BK15, Smartline, GB1*2 boiler 64 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
BK13/BK15, Smartline, GB1*2 boiler 64 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logano GB1*5, Logamatic MC10 boiler 72 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logano GB1*5, Logamatic MC10 boiler 72 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logano GB1*5, Logamatic MC10 boiler 72 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logano GB1*5, Logamatic MC10 boiler 72 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logano GB1*5, Logamatic MC10 boiler 72 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logano GB1*5, Logamatic MC10 boiler 72 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logano GB1*5, Logamatic MC10 boiler 72 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logano GB1*5, Logamatic MC10 boiler 72 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logano GB1*5, Logamatic MC10 boiler 72 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logano GB1*5, Logamatic MC10 boiler 72 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logano GB1*5, Logamatic MC10 boiler 72 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logano GB1*5, Logamatic MC10 boiler 72 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logano GB1*5, Logamatic MC10 boiler 72 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logano GB1*5, Logamatic MC10 boiler 72 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logano GB1*5, Logamatic MC10 boiler 72 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logano GB1*5, Logamatic MC10 boiler 72 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logano GB1*5, Logamatic MC10 boiler 72 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logano GB1*5, Logamatic MC10 boiler 72 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logano GB1*5, Logamatic MC10 boiler 72 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logano GB1*5, Logamatic MC10 boiler 72 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logano GB1*5, Logamatic MC10 boiler 72 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logano GB1*5, Logamatic MC10 boiler 72 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logano GB1*5, Logamatic MC10 boiler 72 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logano GB1*5, Logamatic MC10 boiler 72 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logano GB1*5, Logamatic MC10 boiler 72 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logano GB1*5, Logamatic MC10 boiler 72 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logano GB1*5, Logamatic MC10 boiler 72 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logano GB1*5, Logamatic MC10 boiler 72 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logano GB1*5, Logamatic MC10 boiler 72 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logano GB1*5, Logamatic MC10 boiler 72 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logano GB1*5, Logamatic MC10 boiler 72 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logano GB1*5, Logamatic MC10 boiler 72 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logano GB1*5, Logamatic MC10 boiler 72 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logano GB1*5, Logamatic MC10 boiler 72 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logano GB1*5, Logamatic MC10 boiler 72 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logano GB1*5, Logamatic MC10 boiler 72 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logano GB1*5, Logamatic MC10 boiler 72 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logano GB1*5, Logamatic MC10 boiler 72 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logano GB1*5, Logamatic MC10 boiler 72 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logano GB1*5, Logamatic MC10 boiler 72 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logano GB1*5, Logamatic MC10 boiler 72 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logano GB1*5, Logamatic MC10 boiler 72 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logano GB1*5, Logamatic MC10 boiler 72 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logano GB1*5, Logamatic MC10 boiler 72 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logano GB1*5, Logamatic MC10 boiler 72 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logano GB1*5, Logamatic MC10 boiler 72 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logano GB1*5, Logamatic MC10 boiler 72 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logano GB1*5, Logamatic MC10 boiler 72 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logano GB1*5, Logamatic MC10 boiler 72 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logano GB1*5, Logamatic MC10 boiler 72 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logano GB1*5, Logamatic MC10 boiler 72 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logano GB1*5, Logamatic MC10 boiler 72 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logano GB1*5, Logamatic MC10 boiler 72 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logano GB1*5, Logamatic MC10 boiler 72 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logano GB1*5, Logamatic MC10 boiler 72 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logano GB1*5, Logamatic MC10 boiler 72 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logano GB1*5, Logamatic MC10 boiler 72 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logano GB1*5, Logamatic MC10 boiler 72 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logano GB1*5, Logamatic MC10 boiler 72 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logano GB1*5, Logamatic MC10 boiler 72 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logano GB1*5, Logamatic MC10 boiler 72 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logano GB1*5, Logamatic MC10 boiler 72 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logano GB1*5, Logamatic MC10 boiler 72 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logano GB1*5, Logamatic MC10 boiler 72 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logano GB1*5, Logamatic MC10 boiler 72 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logano GB1*5, Logamatic MC10 boiler 72 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logano GB1*5, Logamatic MC10 boiler 72 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logano GB1*5, Logamatic MC10 boiler 72 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logano GB1*5, Logamatic MC10 boiler 72 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logano GB1*5, Logamatic MC10 boiler 72 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logano GB1*5, Logamatic MC10 boiler 72 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logano GB1*5, Logamatic MC10 boiler 72 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logano GB1*5, Logamatic MC10 boiler 72 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logano GB1*5, Logamatic MC10 boiler 72 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logano GB1*5, Logamatic MC10 boiler 72 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logano GB1*5, Logamatic MC10 boiler 72 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logano GB1*5, Logamatic MC10 boiler 72 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logano GB1*5, Logamatic MC10 boiler 72 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Cascade CM10 boiler 81 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Cascade CM10 boiler 81 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Cascade CM10 boiler 81 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Cascade CM10 boiler 81 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Cascade CM10 boiler 81 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Cascade CM10 boiler 81 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Cascade CM10 boiler 81 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Cascade CM10 boiler 81 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Cascade CM10 boiler 81 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Cascade CM10 boiler 81 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Cascade CM10 boiler 81 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Cascade CM10 boiler 81 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Cascade CM10 boiler 81 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Cascade CM10 boiler 81 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Cascade CM10 boiler 81 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Cascade CM10 boiler 81 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Cascade CM10 boiler 81 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Cascade CM10 boiler 81 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Cascade CM10 boiler 81 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Cascade CM10 boiler 81 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Cascade CM10 boiler 81 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Cascade CM10 boiler 81 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Cascade CM10 boiler 81 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Cascade CM10 boiler 81 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Cascade CM10 boiler 81 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Cascade CM10 boiler 81 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Cascade CM10 boiler 81 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Cascade CM10 boiler 81 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Cascade CM10 boiler 81 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Cascade CM10 boiler 81 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Cascade CM10 boiler 81 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Cascade CM10 boiler 81 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Cascade CM10 boiler 81 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Cascade CM10 boiler 81 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Cascade CM10 boiler 81 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Cascade CM10 boiler 81 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Cascade CM10 boiler 81 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Cascade CM10 boiler 81 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Cascade CM10 boiler 81 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Cascade CM10 boiler 81 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Cascade CM10 boiler 81 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Cascade CM10 boiler 81 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Cascade CM10 boiler 81 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Cascade CM10 boiler 81 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Cascade CM10 boiler 81 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Cascade CM10 boiler 81 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Cascade CM10 boiler 81 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Cascade CM10 boiler 81 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Cascade CM10 boiler 81 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Cascade CM10 boiler 81 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Cascade CM10 boiler 81 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Cascade CM10 boiler 81 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Cascade CM10 boiler 81 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Cascade CM10 boiler 81 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Cascade CM10 boiler 81 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Cascade CM10 boiler 81 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Cascade CM10 boiler 81 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Cascade CM10 boiler 81 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Cascade CM10 boiler 81 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Cascade CM10 boiler 81 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Cascade CM10 boiler 81 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Cascade CM10 boiler 81 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Cascade CM10 boiler 81 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Cascade CM10 boiler 81 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Cascade CM10 boiler 81 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Cascade CM10 boiler 81 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Cascade CM10 boiler 81 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Cascade CM10 boiler 81 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Cascade CM10 boiler 81 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Cascade CM10 boiler 81 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Cascade CM10 boiler 81 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Cascade CM10 boiler 81 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Cascade CM10 boiler 81 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Cascade CM10 boiler 81 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Cascade CM10 boiler 81 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Cascade CM10 boiler 81 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Cascade CM10 boiler 81 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Cascade CM10 boiler 81 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Cascade CM10 boiler 81 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Cascade CM10 boiler 81 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Cascade CM10 boiler 81 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Cascade CM10 boiler 81 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Cascade CM10 boiler 81 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Cascade CM10 boiler 81 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Cascade CM10 boiler 81 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Cascade CM10 boiler 81 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Cascade CM10 boiler 81 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Cascade CM10 boiler 81 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Cascade CM10 boiler 81 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Cascade CM10 boiler 81 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Cascade CM10 boiler 81 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Cascade CM10 boiler 81 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Cascade CM10 boiler 81 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Cascade CM10 boiler 81 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Cascade CM10 boiler 81 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Cascade CM10 boiler 81 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Cascade CM10 boiler 81 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Cascade CM10 boiler 81 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Cascade CM10 boiler 81 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Cascade CM10 boiler 81 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Cascade CM10 boiler 81 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Cascade CM10 boiler 81 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Cascade CM10 boiler 81 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Cascade CM10 boiler 81 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Cascade CM10 boiler 81 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Cascade CM10 boiler 81 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Cascade CM10 boiler 81 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Cascade CM10 boiler 81 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Cascade CM10 boiler 81 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Cascade CM10 boiler 81 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Cascade CM10 boiler 81 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Cascade CM10 boiler 81 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Cascade CM10 boiler 81 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Cascade CM10 boiler 81 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Cascade CM10 boiler 81 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logamax Plus GB022 boiler 84 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logamax Plus GB022 boiler 84 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logamax Plus GB022 boiler 84 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logamax Plus GB022 boiler 84 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logamax Plus GB022 boiler 84 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logamax Plus GB022 boiler 84 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logamax Plus GB022 boiler 84 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logamax Plus GB022 boiler 84 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logamax Plus GB022 boiler 84 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logamax Plus GB022 boiler 84 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logamax Plus GB022 boiler 84 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logamax Plus GB022 boiler 84 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logamax Plus GB022 boiler 84 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logamax Plus GB022 boiler 84 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logamax Plus GB022 boiler 84 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logamax Plus GB022 boiler 84 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logamax Plus GB022 boiler 84 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logamax Plus GB022 boiler 84 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logamax Plus GB022 boiler 84 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logamax Plus GB022 boiler 84 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logamax Plus GB022 boiler 84 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logamax Plus GB022 boiler 84 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logamax Plus GB022 boiler 84 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logamax Plus GB022 boiler 84 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logamax Plus GB022 boiler 84 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logamax Plus GB022 boiler 84 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logamax Plus GB022 boiler 84 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logamax Plus GB022 boiler 84 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logamax Plus GB022 boiler 84 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logamax Plus GB022 boiler 84 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logamax Plus GB022 boiler 84 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logamax Plus GB022 boiler 84 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logamax Plus GB022 boiler 84 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logamax Plus GB022 boiler 84 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logamax Plus GB022 boiler 84 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logamax Plus GB022 boiler 84 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logamax Plus GB022 boiler 84 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logamax Plus GB022 boiler 84 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logamax Plus GB022 boiler 84 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logamax Plus GB022 boiler 84 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logamax Plus GB022 boiler 84 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logamax Plus GB022 boiler 84 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logamax Plus GB022 boiler 84 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logamax Plus GB022 boiler 84 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logamax Plus GB022 boiler 84 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logamax Plus GB022 boiler 84 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logamax Plus GB022 boiler 84 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logamax Plus GB022 boiler 84 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logamax Plus GB022 boiler 84 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logamax Plus GB022 boiler 84 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logamax Plus GB022 boiler 84 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logamax Plus GB022 boiler 84 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logamax Plus GB022 boiler 84 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logamax Plus GB022 boiler 84 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logamax Plus GB022 boiler 84 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logamax Plus GB022 boiler 84 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logamax Plus GB022 boiler 84 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logamax Plus GB022 boiler 84 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logamax Plus GB022 boiler 84 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logamax Plus GB022 boiler 84 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logamax Plus GB022 boiler 84 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logamax Plus GB022 boiler 84 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logamax Plus GB022 boiler 84 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logamax Plus GB022 boiler 84 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logamax Plus GB022 boiler 84 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logamax Plus GB022 boiler 84 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logamax Plus GB022 boiler 84 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logamax Plus GB022 boiler 84 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logamax Plus GB022 boiler 84 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logamax Plus GB022 boiler 84 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logamax Plus GB022 boiler 84 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logamax Plus GB022 boiler 84 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logamax Plus GB022 boiler 84 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logamax Plus GB022 boiler 84 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logamax Plus GB022 boiler 84 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logamax Plus GB022 boiler 84 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logamax Plus GB022 boiler 84 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logamax Plus GB022 boiler 84 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logamax Plus GB022 boiler 84 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logamax Plus GB022 boiler 84 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logamax Plus GB022 boiler 84 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logamax Plus GB022 boiler 84 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logamax Plus GB022 boiler 84 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logamax Plus GB022 boiler 84 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logamax Plus GB022 boiler 84 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logamax Plus GB022 boiler 84 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logamax Plus GB022 boiler 84 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logamax Plus GB022 boiler 84 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logamax Plus GB022 boiler 84 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logamax Plus GB022 boiler 84 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logamax Plus GB022 boiler 84 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logamax Plus GB022 boiler 84 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logamax Plus GB022 boiler 84 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logamax Plus GB022 boiler 84 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logamax Plus GB022 boiler 84 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logamax Plus GB022 boiler 84 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logamax Plus GB022 boiler 84 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logamax Plus GB022 boiler 84 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logamax Plus GB022 boiler 84 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logamax Plus GB022 boiler 84 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logamax Plus GB022 boiler 84 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logamax Plus GB022 boiler 84 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logamax Plus GB022 boiler 84 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logamax Plus GB022 boiler 84 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logamax Plus GB022 boiler 84 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logamax Plus GB022 boiler 84 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logamax Plus GB022 boiler 84 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logamax Plus GB022 boiler 84 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logamax Plus GB022 boiler 84 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logamax Plus GB022 boiler 84 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logamax Plus GB022 boiler 84 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logamax Plus GB022 boiler 84 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logamax Plus GB022 boiler 84 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logamax Plus GB022 boiler 84 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logamax Plus GB022 boiler 84 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Condens, Logamax/Logomatic, Cerapur Top, Greenstar, Generic HT3 boiler 95 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Topline, GB162 boiler 115 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Topline, GB162 boiler 115 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Topline, GB162 boiler 115 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Topline, GB162 boiler 115 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Topline, GB162 boiler 115 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Topline, GB162 boiler 115 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Topline, GB162 boiler 115 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Topline, GB162 boiler 115 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Topline, GB162 boiler 115 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Topline, GB162 boiler 115 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Topline, GB162 boiler 115 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Topline, GB162 boiler 115 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Topline, GB162 boiler 115 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Topline, GB162 boiler 115 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Topline, GB162 boiler 115 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Topline, GB162 boiler 115 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Topline, GB162 boiler 115 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Topline, GB162 boiler 115 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Topline, GB162 boiler 115 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Topline, GB162 boiler 115 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Topline, GB162 boiler 115 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Topline, GB162 boiler 115 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Topline, GB162 boiler 115 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Topline, GB162 boiler 115 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Topline, GB162 boiler 115 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Topline, GB162 boiler 115 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Topline, GB162 boiler 115 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Topline, GB162 boiler 115 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Topline, GB162 boiler 115 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Topline, GB162 boiler 115 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Topline, GB162 boiler 115 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Topline, GB162 boiler 115 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Topline, GB162 boiler 115 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Topline, GB162 boiler 115 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Topline, GB162 boiler 115 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Topline, GB162 boiler 115 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Topline, GB162 boiler 115 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Topline, GB162 boiler 115 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Topline, GB162 boiler 115 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Topline, GB162 boiler 115 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Topline, GB162 boiler 115 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Topline, GB162 boiler 115 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Topline, GB162 boiler 115 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Topline, GB162 boiler 115 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Topline, GB162 boiler 115 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Topline, GB162 boiler 115 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Topline, GB162 boiler 115 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Topline, GB162 boiler 115 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Topline, GB162 boiler 115 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Topline, GB162 boiler 115 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Topline, GB162 boiler 115 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Topline, GB162 boiler 115 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Topline, GB162 boiler 115 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Topline, GB162 boiler 115 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Topline, GB162 boiler 115 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Topline, GB162 boiler 115 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Topline, GB162 boiler 115 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Topline, GB162 boiler 115 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Topline, GB162 boiler 115 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Topline, GB162 boiler 115 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Topline, GB162 boiler 115 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Topline, GB162 boiler 115 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Topline, GB162 boiler 115 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Topline, GB162 boiler 115 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Topline, GB162 boiler 115 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Topline, GB162 boiler 115 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Topline, GB162 boiler 115 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Topline, GB162 boiler 115 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Topline, GB162 boiler 115 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Topline, GB162 boiler 115 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Topline, GB162 boiler 115 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Topline, GB162 boiler 115 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Topline, GB162 boiler 115 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Topline, GB162 boiler 115 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Topline, GB162 boiler 115 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Topline, GB162 boiler 115 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Topline, GB162 boiler 115 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Topline, GB162 boiler 115 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Topline, GB162 boiler 115 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Topline, GB162 boiler 115 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Topline, GB162 boiler 115 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Topline, GB162 boiler 115 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Topline, GB162 boiler 115 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Topline, GB162 boiler 115 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Topline, GB162 boiler 115 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Topline, GB162 boiler 115 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Topline, GB162 boiler 115 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Topline, GB162 boiler 115 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Topline, GB162 boiler 115 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Topline, GB162 boiler 115 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Topline, GB162 boiler 115 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Topline, GB162 boiler 115 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Topline, GB162 boiler 115 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Topline, GB162 boiler 115 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Topline, GB162 boiler 115 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Topline, GB162 boiler 115 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Topline, GB162 boiler 115 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Topline, GB162 boiler 115 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Topline, GB162 boiler 115 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Topline, GB162 boiler 115 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Topline, GB162 boiler 115 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Topline, GB162 boiler 115 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Topline, GB162 boiler 115 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Topline, GB162 boiler 115 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Topline, GB162 boiler 115 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Topline, GB162 boiler 115 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Topline, GB162 boiler 115 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Topline, GB162 boiler 115 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Topline, GB162 boiler 115 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Topline, GB162 boiler 115 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Topline, GB162 boiler 115 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Topline, GB162 boiler 115 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Topline, GB162 boiler 115 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Topline, GB162 boiler 115 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Topline, GB162 boiler 115 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Cascade MCM10 boiler 121 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Cascade MCM10 boiler 121 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Cascade MCM10 boiler 121 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Cascade MCM10 boiler 121 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Cascade MCM10 boiler 121 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Cascade MCM10 boiler 121 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Cascade MCM10 boiler 121 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Cascade MCM10 boiler 121 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Cascade MCM10 boiler 121 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Cascade MCM10 boiler 121 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Cascade MCM10 boiler 121 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Cascade MCM10 boiler 121 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Cascade MCM10 boiler 121 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Cascade MCM10 boiler 121 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Cascade MCM10 boiler 121 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Cascade MCM10 boiler 121 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Cascade MCM10 boiler 121 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Cascade MCM10 boiler 121 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Cascade MCM10 boiler 121 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Cascade MCM10 boiler 121 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Cascade MCM10 boiler 121 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Cascade MCM10 boiler 121 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Cascade MCM10 boiler 121 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Cascade MCM10 boiler 121 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Cascade MCM10 boiler 121 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Cascade MCM10 boiler 121 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Cascade MCM10 boiler 121 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Cascade MCM10 boiler 121 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Cascade MCM10 boiler 121 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Cascade MCM10 boiler 121 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Cascade MCM10 boiler 121 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Cascade MCM10 boiler 121 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Cascade MCM10 boiler 121 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Cascade MCM10 boiler 121 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Cascade MCM10 boiler 121 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Cascade MCM10 boiler 121 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Cascade MCM10 boiler 121 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Cascade MCM10 boiler 121 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Cascade MCM10 boiler 121 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Cascade MCM10 boiler 121 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Cascade MCM10 boiler 121 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Cascade MCM10 boiler 121 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Cascade MCM10 boiler 121 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Cascade MCM10 boiler 121 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Cascade MCM10 boiler 121 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Cascade MCM10 boiler 121 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Cascade MCM10 boiler 121 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Cascade MCM10 boiler 121 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Cascade MCM10 boiler 121 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Cascade MCM10 boiler 121 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Cascade MCM10 boiler 121 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Cascade MCM10 boiler 121 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Cascade MCM10 boiler 121 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Cascade MCM10 boiler 121 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Cascade MCM10 boiler 121 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Cascade MCM10 boiler 121 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Cascade MCM10 boiler 121 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Cascade MCM10 boiler 121 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Cascade MCM10 boiler 121 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Cascade MCM10 boiler 121 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Cascade MCM10 boiler 121 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Cascade MCM10 boiler 121 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Cascade MCM10 boiler 121 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Cascade MCM10 boiler 121 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Cascade MCM10 boiler 121 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Cascade MCM10 boiler 121 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Cascade MCM10 boiler 121 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Cascade MCM10 boiler 121 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Cascade MCM10 boiler 121 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Cascade MCM10 boiler 121 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Cascade MCM10 boiler 121 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Cascade MCM10 boiler 121 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Cascade MCM10 boiler 121 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Cascade MCM10 boiler 121 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Cascade MCM10 boiler 121 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Cascade MCM10 boiler 121 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Cascade MCM10 boiler 121 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Cascade MCM10 boiler 121 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Cascade MCM10 boiler 121 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Cascade MCM10 boiler 121 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Cascade MCM10 boiler 121 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Cascade MCM10 boiler 121 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Cascade MCM10 boiler 121 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Cascade MCM10 boiler 121 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Cascade MCM10 boiler 121 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Cascade MCM10 boiler 121 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Cascade MCM10 boiler 121 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Cascade MCM10 boiler 121 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Cascade MCM10 boiler 121 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Cascade MCM10 boiler 121 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Cascade MCM10 boiler 121 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Cascade MCM10 boiler 121 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Cascade MCM10 boiler 121 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Cascade MCM10 boiler 121 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Cascade MCM10 boiler 121 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Cascade MCM10 boiler 121 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Cascade MCM10 boiler 121 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Cascade MCM10 boiler 121 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Cascade MCM10 boiler 121 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Cascade MCM10 boiler 121 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Cascade MCM10 boiler 121 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Cascade MCM10 boiler 121 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Cascade MCM10 boiler 121 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Cascade MCM10 boiler 121 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Cascade MCM10 boiler 121 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Cascade MCM10 boiler 121 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Cascade MCM10 boiler 121 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Cascade MCM10 boiler 121 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Cascade MCM10 boiler 121 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Cascade MCM10 boiler 121 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Cascade MCM10 boiler 121 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Cascade MCM10 boiler 121 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Cascade MCM10 boiler 121 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Cascade MCM10 boiler 121 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Cascade MCM10 boiler 121 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Proline boiler 122 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Proline boiler 122 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Proline boiler 122 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Proline boiler 122 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Proline boiler 122 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Proline boiler 122 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Proline boiler 122 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Proline boiler 122 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Proline boiler 122 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Proline boiler 122 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Proline boiler 122 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Proline boiler 122 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Proline boiler 122 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Proline boiler 122 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Proline boiler 122 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Proline boiler 122 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Proline boiler 122 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Proline boiler 122 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Proline boiler 122 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Proline boiler 122 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Proline boiler 122 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Proline boiler 122 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Proline boiler 122 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Proline boiler 122 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Proline boiler 122 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Proline boiler 122 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Proline boiler 122 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Proline boiler 122 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Proline boiler 122 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Proline boiler 122 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Proline boiler 122 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Proline boiler 122 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Proline boiler 122 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Proline boiler 122 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Proline boiler 122 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Proline boiler 122 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Proline boiler 122 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Proline boiler 122 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Proline boiler 122 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Proline boiler 122 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Proline boiler 122 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Proline boiler 122 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Proline boiler 122 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Proline boiler 122 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Proline boiler 122 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Proline boiler 122 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Proline boiler 122 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Proline boiler 122 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Proline boiler 122 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Proline boiler 122 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Proline boiler 122 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Proline boiler 122 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Proline boiler 122 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Proline boiler 122 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Proline boiler 122 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Proline boiler 122 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Proline boiler 122 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Proline boiler 122 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Proline boiler 122 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Proline boiler 122 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Proline boiler 122 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Proline boiler 122 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Proline boiler 122 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Proline boiler 122 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Proline boiler 122 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Proline boiler 122 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Proline boiler 122 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Proline boiler 122 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Proline boiler 122 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Proline boiler 122 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Proline boiler 122 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Proline boiler 122 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Proline boiler 122 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Proline boiler 122 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Proline boiler 122 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Proline boiler 122 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Proline boiler 122 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Proline boiler 122 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Proline boiler 122 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Proline boiler 122 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Proline boiler 122 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Proline boiler 122 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Proline boiler 122 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Proline boiler 122 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Proline boiler 122 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Proline boiler 122 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Proline boiler 122 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Proline boiler 122 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Proline boiler 122 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Proline boiler 122 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Proline boiler 122 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Proline boiler 122 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Proline boiler 122 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Proline boiler 122 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Proline boiler 122 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Proline boiler 122 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Proline boiler 122 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Proline boiler 122 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Proline boiler 122 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Proline boiler 122 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Proline boiler 122 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Proline boiler 122 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Proline boiler 122 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Proline boiler 122 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Proline boiler 122 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Proline boiler 122 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Proline boiler 122 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Proline boiler 122 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Proline boiler 122 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Proline boiler 122 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Proline boiler 122 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Proline boiler 122 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Proline boiler 122 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Proline boiler 122 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Proline boiler 122 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
GB*72, Trendline, Cerapur, Greenstar Si boiler 123 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
GB212 boiler 131 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
GB212 boiler 131 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
GB212 boiler 131 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
GB212 boiler 131 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
GB212 boiler 131 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
GB212 boiler 131 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
GB212 boiler 131 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
GB212 boiler 131 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
GB212 boiler 131 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
GB212 boiler 131 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
GB212 boiler 131 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
GB212 boiler 131 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
GB212 boiler 131 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
GB212 boiler 131 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
GB212 boiler 131 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
GB212 boiler 131 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
GB212 boiler 131 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
GB212 boiler 131 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
GB212 boiler 131 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
GB212 boiler 131 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
GB212 boiler 131 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
GB212 boiler 131 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
GB212 boiler 131 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
GB212 boiler 131 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
GB212 boiler 131 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
GB212 boiler 131 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
GB212 boiler 131 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
GB212 boiler 131 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
GB212 boiler 131 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
GB212 boiler 131 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
GB212 boiler 131 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
GB212 boiler 131 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
GB212 boiler 131 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
GB212 boiler 131 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
GB212 boiler 131 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
GB212 boiler 131 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
GB212 boiler 131 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
GB212 boiler 131 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
GB212 boiler 131 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
GB212 boiler 131 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
GB212 boiler 131 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
GB212 boiler 131 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
GB212 boiler 131 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
GB212 boiler 131 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
GB212 boiler 131 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
GB212 boiler 131 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
GB212 boiler 131 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
GB212 boiler 131 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
GB212 boiler 131 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
GB212 boiler 131 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
GB212 boiler 131 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
GB212 boiler 131 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
GB212 boiler 131 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
GB212 boiler 131 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
GB212 boiler 131 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
GB212 boiler 131 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
GB212 boiler 131 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
GB212 boiler 131 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
GB212 boiler 131 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
GB212 boiler 131 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
GB212 boiler 131 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
GB212 boiler 131 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
GB212 boiler 131 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
GB212 boiler 131 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
GB212 boiler 131 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
GB212 boiler 131 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
GB212 boiler 131 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
GB212 boiler 131 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
GB212 boiler 131 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
GB212 boiler 131 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
GB212 boiler 131 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
GB212 boiler 131 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
GB212 boiler 131 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
GB212 boiler 131 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
GB212 boiler 131 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
GB212 boiler 131 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
GB212 boiler 131 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
GB212 boiler 131 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
GB212 boiler 131 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
GB212 boiler 131 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
GB212 boiler 131 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
GB212 boiler 131 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
GB212 boiler 131 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
GB212 boiler 131 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
GB212 boiler 131 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
GB212 boiler 131 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
GB212 boiler 131 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
GB212 boiler 131 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
GB212 boiler 131 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
GB212 boiler 131 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
GB212 boiler 131 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
GB212 boiler 131 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
GB212 boiler 131 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
GB212 boiler 131 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
GB212 boiler 131 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
GB212 boiler 131 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
GB212 boiler 131 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
GB212 boiler 131 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
GB212 boiler 131 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
GB212 boiler 131 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
GB212 boiler 131 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
GB212 boiler 131 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
GB212 boiler 131 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
GB212 boiler 131 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
GB212 boiler 131 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
GB212 boiler 131 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
GB212 boiler 131 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
GB212 boiler 131 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
GB212 boiler 131 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
GB212 boiler 131 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
GB212 boiler 131 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
GB212 boiler 131 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
GB212 boiler 131 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
GB212 boiler 131 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
GB212 boiler 131 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
GC7000F boiler 132 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
GC7000F boiler 132 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
GC7000F boiler 132 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
GC7000F boiler 132 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
GC7000F boiler 132 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
GC7000F boiler 132 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
GC7000F boiler 132 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
GC7000F boiler 132 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
GC7000F boiler 132 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
GC7000F boiler 132 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
GC7000F boiler 132 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
GC7000F boiler 132 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
GC7000F boiler 132 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
GC7000F boiler 132 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
GC7000F boiler 132 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
GC7000F boiler 132 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
GC7000F boiler 132 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
GC7000F boiler 132 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
GC7000F boiler 132 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
GC7000F boiler 132 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
GC7000F boiler 132 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
GC7000F boiler 132 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
GC7000F boiler 132 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
GC7000F boiler 132 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
GC7000F boiler 132 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
GC7000F boiler 132 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
GC7000F boiler 132 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
GC7000F boiler 132 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
GC7000F boiler 132 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
GC7000F boiler 132 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
GC7000F boiler 132 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
GC7000F boiler 132 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
GC7000F boiler 132 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
GC7000F boiler 132 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
GC7000F boiler 132 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
GC7000F boiler 132 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
GC7000F boiler 132 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
GC7000F boiler 132 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
GC7000F boiler 132 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
GC7000F boiler 132 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
GC7000F boiler 132 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
GC7000F boiler 132 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
GC7000F boiler 132 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
GC7000F boiler 132 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
GC7000F boiler 132 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
GC7000F boiler 132 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
GC7000F boiler 132 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
GC7000F boiler 132 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
GC7000F boiler 132 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
GC7000F boiler 132 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
GC7000F boiler 132 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
GC7000F boiler 132 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
GC7000F boiler 132 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
GC7000F boiler 132 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
GC7000F boiler 132 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
GC7000F boiler 132 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
GC7000F boiler 132 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
GC7000F boiler 132 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
GC7000F boiler 132 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
GC7000F boiler 132 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
GC7000F boiler 132 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
GC7000F boiler 132 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
GC7000F boiler 132 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
GC7000F boiler 132 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
GC7000F boiler 132 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
GC7000F boiler 132 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
GC7000F boiler 132 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
GC7000F boiler 132 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
GC7000F boiler 132 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
GC7000F boiler 132 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
GC7000F boiler 132 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
GC7000F boiler 132 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
GC7000F boiler 132 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
GC7000F boiler 132 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
GC7000F boiler 132 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
GC7000F boiler 132 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
GC7000F boiler 132 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
GC7000F boiler 132 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
GC7000F boiler 132 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
GC7000F boiler 132 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
GC7000F boiler 132 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
GC7000F boiler 132 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
GC7000F boiler 132 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
GC7000F boiler 132 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
GC7000F boiler 132 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
GC7000F boiler 132 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
GC7000F boiler 132 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
GC7000F boiler 132 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
GC7000F boiler 132 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
GC7000F boiler 132 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
GC7000F boiler 132 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
GC7000F boiler 132 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
GC7000F boiler 132 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
GC7000F boiler 132 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
GC7000F boiler 132 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
GC7000F boiler 132 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
GC7000F boiler 132 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
GC7000F boiler 132 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
GC7000F boiler 132 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
GC7000F boiler 132 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
GC7000F boiler 132 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
GC7000F boiler 132 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
GC7000F boiler 132 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
GC7000F boiler 132 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
GC7000F boiler 132 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
GC7000F boiler 132 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
GC7000F boiler 132 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
GC7000F boiler 132 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
GC7000F boiler 132 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
GC7000F boiler 132 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
GC7000F boiler 132 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
GC7000F boiler 132 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
GC7000F boiler 132 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
GC7000F boiler 132 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
GC7000F boiler 132 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logano GB125/KB195i, Logamatic MC110 boiler 133 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logano GB125/KB195i, Logamatic MC110 boiler 133 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logano GB125/KB195i, Logamatic MC110 boiler 133 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logano GB125/KB195i, Logamatic MC110 boiler 133 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Greenstar 30Ri Compact boiler 154 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Greenstar 30Ri Compact boiler 154 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Greenstar 30Ri Compact boiler 154 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Greenstar 30Ri Compact boiler 154 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Greenstar 30Ri Compact boiler 154 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Greenstar 30Ri Compact boiler 154 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Greenstar 30Ri Compact boiler 154 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Greenstar 30Ri Compact boiler 154 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Greenstar 30Ri Compact boiler 154 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Greenstar 30Ri Compact boiler 154 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Greenstar 30Ri Compact boiler 154 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Greenstar 30Ri Compact boiler 154 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Greenstar 30Ri Compact boiler 154 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Greenstar 30Ri Compact boiler 154 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Greenstar 30Ri Compact boiler 154 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Greenstar 30Ri Compact boiler 154 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Greenstar 30Ri Compact boiler 154 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Greenstar 30Ri Compact boiler 154 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Greenstar 30Ri Compact boiler 154 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Greenstar 30Ri Compact boiler 154 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Greenstar 30Ri Compact boiler 154 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Greenstar 30Ri Compact boiler 154 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Greenstar 30Ri Compact boiler 154 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Greenstar 30Ri Compact boiler 154 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Greenstar 30Ri Compact boiler 154 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Greenstar 30Ri Compact boiler 154 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Greenstar 30Ri Compact boiler 154 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Greenstar 30Ri Compact boiler 154 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Greenstar 30Ri Compact boiler 154 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Greenstar 30Ri Compact boiler 154 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Greenstar 30Ri Compact boiler 154 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Greenstar 30Ri Compact boiler 154 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Greenstar 30Ri Compact boiler 154 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Greenstar 30Ri Compact boiler 154 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Greenstar 30Ri Compact boiler 154 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Greenstar 30Ri Compact boiler 154 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Greenstar 30Ri Compact boiler 154 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Greenstar 30Ri Compact boiler 154 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Greenstar 30Ri Compact boiler 154 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Greenstar 30Ri Compact boiler 154 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Greenstar 30Ri Compact boiler 154 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Greenstar 30Ri Compact boiler 154 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Greenstar 30Ri Compact boiler 154 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Greenstar 30Ri Compact boiler 154 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Greenstar 30Ri Compact boiler 154 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Greenstar 30Ri Compact boiler 154 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Greenstar 30Ri Compact boiler 154 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Greenstar 30Ri Compact boiler 154 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Greenstar 30Ri Compact boiler 154 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Greenstar 30Ri Compact boiler 154 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Greenstar 30Ri Compact boiler 154 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Greenstar 30Ri Compact boiler 154 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Greenstar 30Ri Compact boiler 154 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Greenstar 30Ri Compact boiler 154 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Greenstar 30Ri Compact boiler 154 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Greenstar 30Ri Compact boiler 154 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Greenstar 30Ri Compact boiler 154 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Greenstar 30Ri Compact boiler 154 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Greenstar 30Ri Compact boiler 154 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Greenstar 30Ri Compact boiler 154 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Greenstar 30Ri Compact boiler 154 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Greenstar 30Ri Compact boiler 154 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Greenstar 30Ri Compact boiler 154 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Greenstar 30Ri Compact boiler 154 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Greenstar 30Ri Compact boiler 154 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Greenstar 30Ri Compact boiler 154 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Greenstar 30Ri Compact boiler 154 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Greenstar 30Ri Compact boiler 154 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Greenstar 30Ri Compact boiler 154 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Greenstar 30Ri Compact boiler 154 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Greenstar 30Ri Compact boiler 154 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Greenstar 30Ri Compact boiler 154 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Greenstar 30Ri Compact boiler 154 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Greenstar 30Ri Compact boiler 154 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Greenstar 30Ri Compact boiler 154 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Greenstar 30Ri Compact boiler 154 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Greenstar 30Ri Compact boiler 154 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Greenstar 30Ri Compact boiler 154 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Greenstar 30Ri Compact boiler 154 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Greenstar 30Ri Compact boiler 154 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Greenstar 30Ri Compact boiler 154 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Greenstar 30Ri Compact boiler 154 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Greenstar 30Ri Compact boiler 154 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Greenstar 30Ri Compact boiler 154 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Greenstar 30Ri Compact boiler 154 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Greenstar 30Ri Compact boiler 154 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Greenstar 30Ri Compact boiler 154 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Greenstar 30Ri Compact boiler 154 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Greenstar 30Ri Compact boiler 154 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Greenstar 30Ri Compact boiler 154 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Greenstar 30Ri Compact boiler 154 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Greenstar 30Ri Compact boiler 154 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Greenstar 30Ri Compact boiler 154 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Greenstar 30Ri Compact boiler 154 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Greenstar 30Ri Compact boiler 154 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Greenstar 30Ri Compact boiler 154 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Greenstar 30Ri Compact boiler 154 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Greenstar 30Ri Compact boiler 154 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Greenstar 30Ri Compact boiler 154 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Greenstar 30Ri Compact boiler 154 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Greenstar 30Ri Compact boiler 154 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Greenstar 30Ri Compact boiler 154 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Greenstar 30Ri Compact boiler 154 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Greenstar 30Ri Compact boiler 154 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Greenstar 30Ri Compact boiler 154 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Greenstar 30Ri Compact boiler 154 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Greenstar 30Ri Compact boiler 154 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Greenstar 30Ri Compact boiler 154 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Greenstar 30Ri Compact boiler 154 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Greenstar 30Ri Compact boiler 154 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Greenstar 30Ri Compact boiler 154 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Greenstar 30Ri Compact boiler 154 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Greenstar 30Ri Compact boiler 154 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Greenstar 30Ri Compact boiler 154 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Greenstar 30Ri Compact boiler 154 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Suprapur-o boiler 155 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Suprapur-o boiler 155 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Suprapur-o boiler 155 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Suprapur-o boiler 155 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Suprapur-o boiler 155 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Suprapur-o boiler 155 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Suprapur-o boiler 155 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Suprapur-o boiler 155 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Suprapur-o boiler 155 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Suprapur-o boiler 155 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Suprapur-o boiler 155 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Suprapur-o boiler 155 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Suprapur-o boiler 155 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Suprapur-o boiler 155 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Suprapur-o boiler 155 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Suprapur-o boiler 155 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Suprapur-o boiler 155 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Suprapur-o boiler 155 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Suprapur-o boiler 155 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Suprapur-o boiler 155 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Suprapur-o boiler 155 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Suprapur-o boiler 155 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Suprapur-o boiler 155 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Suprapur-o boiler 155 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Suprapur-o boiler 155 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Suprapur-o boiler 155 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Suprapur-o boiler 155 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Suprapur-o boiler 155 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Suprapur-o boiler 155 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Suprapur-o boiler 155 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Suprapur-o boiler 155 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Suprapur-o boiler 155 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Suprapur-o boiler 155 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Suprapur-o boiler 155 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Suprapur-o boiler 155 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Suprapur-o boiler 155 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Suprapur-o boiler 155 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Suprapur-o boiler 155 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Suprapur-o boiler 155 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Suprapur-o boiler 155 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Suprapur-o boiler 155 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Suprapur-o boiler 155 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Suprapur-o boiler 155 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Suprapur-o boiler 155 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Suprapur-o boiler 155 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Suprapur-o boiler 155 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Suprapur-o boiler 155 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Suprapur-o boiler 155 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Suprapur-o boiler 155 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Suprapur-o boiler 155 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Suprapur-o boiler 155 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Suprapur-o boiler 155 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Suprapur-o boiler 155 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Suprapur-o boiler 155 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Suprapur-o boiler 155 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Suprapur-o boiler 155 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Suprapur-o boiler 155 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Suprapur-o boiler 155 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Suprapur-o boiler 155 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Suprapur-o boiler 155 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Suprapur-o boiler 155 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Suprapur-o boiler 155 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Suprapur-o boiler 155 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Suprapur-o boiler 155 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Suprapur-o boiler 155 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Suprapur-o boiler 155 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Suprapur-o boiler 155 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Suprapur-o boiler 155 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Suprapur-o boiler 155 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Suprapur-o boiler 155 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Suprapur-o boiler 155 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Suprapur-o boiler 155 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Suprapur-o boiler 155 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Suprapur-o boiler 155 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Suprapur-o boiler 155 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Suprapur-o boiler 155 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Suprapur-o boiler 155 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Suprapur-o boiler 155 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Suprapur-o boiler 155 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Suprapur-o boiler 155 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Suprapur-o boiler 155 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Suprapur-o boiler 155 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Suprapur-o boiler 155 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Suprapur-o boiler 155 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Suprapur-o boiler 155 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Suprapur-o boiler 155 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Suprapur-o boiler 155 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Suprapur-o boiler 155 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Suprapur-o boiler 155 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Suprapur-o boiler 155 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Suprapur-o boiler 155 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Suprapur-o boiler 155 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Suprapur-o boiler 155 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Suprapur-o boiler 155 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Suprapur-o boiler 155 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Suprapur-o boiler 155 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Suprapur-o boiler 155 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Suprapur-o boiler 155 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Suprapur-o boiler 155 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Suprapur-o boiler 155 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Suprapur-o boiler 155 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Suprapur-o boiler 155 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Suprapur-o boiler 155 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Suprapur-o boiler 155 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Suprapur-o boiler 155 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Suprapur-o boiler 155 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Suprapur-o boiler 155 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Suprapur-o boiler 155 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Suprapur-o boiler 155 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Suprapur-o boiler 155 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Suprapur-o boiler 155 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Suprapur-o boiler 155 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Suprapur-o boiler 155 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Suprapur-o boiler 155 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Suprapur-o boiler 155 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Cerapur Aero boiler 167 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Cerapur Aero boiler 167 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Cerapur Aero boiler 167 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Cerapur Aero boiler 167 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Cerapur Aero boiler 167 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Cerapur Aero boiler 167 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Cerapur Aero boiler 167 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Cerapur Aero boiler 167 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Cerapur Aero boiler 167 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Cerapur Aero boiler 167 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Cerapur Aero boiler 167 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Cerapur Aero boiler 167 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Cerapur Aero boiler 167 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Cerapur Aero boiler 167 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Cerapur Aero boiler 167 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Cerapur Aero boiler 167 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Cerapur Aero boiler 167 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Cerapur Aero boiler 167 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Cerapur Aero boiler 167 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Cerapur Aero boiler 167 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Cerapur Aero boiler 167 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Cerapur Aero boiler 167 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Cerapur Aero boiler 167 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Cerapur Aero boiler 167 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Cerapur Aero boiler 167 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Cerapur Aero boiler 167 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Cerapur Aero boiler 167 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Cerapur Aero boiler 167 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Cerapur Aero boiler 167 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Cerapur Aero boiler 167 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Cerapur Aero boiler 167 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Cerapur Aero boiler 167 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Cerapur Aero boiler 167 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Cerapur Aero boiler 167 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Cerapur Aero boiler 167 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Cerapur Aero boiler 167 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Cerapur Aero boiler 167 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Cerapur Aero boiler 167 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Cerapur Aero boiler 167 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Cerapur Aero boiler 167 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Cerapur Aero boiler 167 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Cerapur Aero boiler 167 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Cerapur Aero boiler 167 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Cerapur Aero boiler 167 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Cerapur Aero boiler 167 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Cerapur Aero boiler 167 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Cerapur Aero boiler 167 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Cerapur Aero boiler 167 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Cerapur Aero boiler 167 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Cerapur Aero boiler 167 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Cerapur Aero boiler 167 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Cerapur Aero boiler 167 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Cerapur Aero boiler 167 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Cerapur Aero boiler 167 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Cerapur Aero boiler 167 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Cerapur Aero boiler 167 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Cerapur Aero boiler 167 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Cerapur Aero boiler 167 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Cerapur Aero boiler 167 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Cerapur Aero boiler 167 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Cerapur Aero boiler 167 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Cerapur Aero boiler 167 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Cerapur Aero boiler 167 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Cerapur Aero boiler 167 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Cerapur Aero boiler 167 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Cerapur Aero boiler 167 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Cerapur Aero boiler 167 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Cerapur Aero boiler 167 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Cerapur Aero boiler 167 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Cerapur Aero boiler 167 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Cerapur Aero boiler 167 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Cerapur Aero boiler 167 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Cerapur Aero boiler 167 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Cerapur Aero boiler 167 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Cerapur Aero boiler 167 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Cerapur Aero boiler 167 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Cerapur Aero boiler 167 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Cerapur Aero boiler 167 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Cerapur Aero boiler 167 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Cerapur Aero boiler 167 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Cerapur Aero boiler 167 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Cerapur Aero boiler 167 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Cerapur Aero boiler 167 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Cerapur Aero boiler 167 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Cerapur Aero boiler 167 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Cerapur Aero boiler 167 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Cerapur Aero boiler 167 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Cerapur Aero boiler 167 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Cerapur Aero boiler 167 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Cerapur Aero boiler 167 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Cerapur Aero boiler 167 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Cerapur Aero boiler 167 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Cerapur Aero boiler 167 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Cerapur Aero boiler 167 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Cerapur Aero boiler 167 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Cerapur Aero boiler 167 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Cerapur Aero boiler 167 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Cerapur Aero boiler 167 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Cerapur Aero boiler 167 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Cerapur Aero boiler 167 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Cerapur Aero boiler 167 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Cerapur Aero boiler 167 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Cerapur Aero boiler 167 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Cerapur Aero boiler 167 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Cerapur Aero boiler 167 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Cerapur Aero boiler 167 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Cerapur Aero boiler 167 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Cerapur Aero boiler 167 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Cerapur Aero boiler 167 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Cerapur Aero boiler 167 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Cerapur Aero boiler 167 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Cerapur Aero boiler 167 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Cerapur Aero boiler 167 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Cerapur Aero boiler 167 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Cerapur Aero boiler 167 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Hybrid Heatpump boiler 168 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Hybrid Heatpump boiler 168 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Hybrid Heatpump boiler 168 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Hybrid Heatpump boiler 168 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Hybrid Heatpump boiler 168 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Hybrid Heatpump boiler 168 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Hybrid Heatpump boiler 168 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Hybrid Heatpump boiler 168 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Hybrid Heatpump boiler 168 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Hybrid Heatpump boiler 168 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Hybrid Heatpump boiler 168 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Hybrid Heatpump boiler 168 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Hybrid Heatpump boiler 168 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Hybrid Heatpump boiler 168 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Hybrid Heatpump boiler 168 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Hybrid Heatpump boiler 168 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Hybrid Heatpump boiler 168 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Hybrid Heatpump boiler 168 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Hybrid Heatpump boiler 168 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Hybrid Heatpump boiler 168 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Hybrid Heatpump boiler 168 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Hybrid Heatpump boiler 168 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Hybrid Heatpump boiler 168 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Hybrid Heatpump boiler 168 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Hybrid Heatpump boiler 168 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Hybrid Heatpump boiler 168 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Hybrid Heatpump boiler 168 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Hybrid Heatpump boiler 168 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Hybrid Heatpump boiler 168 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Hybrid Heatpump boiler 168 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Hybrid Heatpump boiler 168 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Hybrid Heatpump boiler 168 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Hybrid Heatpump boiler 168 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Hybrid Heatpump boiler 168 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Hybrid Heatpump boiler 168 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Hybrid Heatpump boiler 168 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Hybrid Heatpump boiler 168 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Hybrid Heatpump boiler 168 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Hybrid Heatpump boiler 168 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Hybrid Heatpump boiler 168 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Hybrid Heatpump boiler 168 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Hybrid Heatpump boiler 168 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Hybrid Heatpump boiler 168 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Hybrid Heatpump boiler 168 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Hybrid Heatpump boiler 168 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Hybrid Heatpump boiler 168 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Hybrid Heatpump boiler 168 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Hybrid Heatpump boiler 168 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Hybrid Heatpump boiler 168 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Hybrid Heatpump boiler 168 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Hybrid Heatpump boiler 168 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Hybrid Heatpump boiler 168 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Hybrid Heatpump boiler 168 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Hybrid Heatpump boiler 168 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Hybrid Heatpump boiler 168 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Hybrid Heatpump boiler 168 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Hybrid Heatpump boiler 168 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Hybrid Heatpump boiler 168 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Hybrid Heatpump boiler 168 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Hybrid Heatpump boiler 168 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Hybrid Heatpump boiler 168 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Hybrid Heatpump boiler 168 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Hybrid Heatpump boiler 168 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Hybrid Heatpump boiler 168 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Hybrid Heatpump boiler 168 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Hybrid Heatpump boiler 168 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Hybrid Heatpump boiler 168 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Hybrid Heatpump boiler 168 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Hybrid Heatpump boiler 168 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Hybrid Heatpump boiler 168 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Hybrid Heatpump boiler 168 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Hybrid Heatpump boiler 168 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Hybrid Heatpump boiler 168 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Hybrid Heatpump boiler 168 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Hybrid Heatpump boiler 168 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Hybrid Heatpump boiler 168 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Hybrid Heatpump boiler 168 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Hybrid Heatpump boiler 168 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Hybrid Heatpump boiler 168 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Hybrid Heatpump boiler 168 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Hybrid Heatpump boiler 168 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Hybrid Heatpump boiler 168 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Hybrid Heatpump boiler 168 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Hybrid Heatpump boiler 168 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Hybrid Heatpump boiler 168 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Hybrid Heatpump boiler 168 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Hybrid Heatpump boiler 168 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Hybrid Heatpump boiler 168 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Hybrid Heatpump boiler 168 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Hybrid Heatpump boiler 168 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Hybrid Heatpump boiler 168 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Hybrid Heatpump boiler 168 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Hybrid Heatpump boiler 168 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Hybrid Heatpump boiler 168 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Hybrid Heatpump boiler 168 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Hybrid Heatpump boiler 168 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Hybrid Heatpump boiler 168 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Hybrid Heatpump boiler 168 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Hybrid Heatpump boiler 168 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Hybrid Heatpump boiler 168 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Hybrid Heatpump boiler 168 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Hybrid Heatpump boiler 168 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Hybrid Heatpump boiler 168 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Hybrid Heatpump boiler 168 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Hybrid Heatpump boiler 168 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Hybrid Heatpump boiler 168 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Hybrid Heatpump boiler 168 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Hybrid Heatpump boiler 168 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Hybrid Heatpump boiler 168 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Hybrid Heatpump boiler 168 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Hybrid Heatpump boiler 168 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Hybrid Heatpump boiler 168 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Hybrid Heatpump boiler 168 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Hybrid Heatpump boiler 168 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Hybrid Heatpump boiler 168 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logano GB212 boiler 170 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logano GB212 boiler 170 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logano GB212 boiler 170 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logano GB212 boiler 170 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logano GB212 boiler 170 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logano GB212 boiler 170 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logano GB212 boiler 170 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logano GB212 boiler 170 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logano GB212 boiler 170 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logano GB212 boiler 170 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logano GB212 boiler 170 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logano GB212 boiler 170 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logano GB212 boiler 170 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logano GB212 boiler 170 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logano GB212 boiler 170 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logano GB212 boiler 170 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logano GB212 boiler 170 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logano GB212 boiler 170 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logano GB212 boiler 170 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logano GB212 boiler 170 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logano GB212 boiler 170 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logano GB212 boiler 170 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logano GB212 boiler 170 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logano GB212 boiler 170 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logano GB212 boiler 170 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logano GB212 boiler 170 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logano GB212 boiler 170 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logano GB212 boiler 170 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logano GB212 boiler 170 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logano GB212 boiler 170 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logano GB212 boiler 170 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logano GB212 boiler 170 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logano GB212 boiler 170 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logano GB212 boiler 170 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logano GB212 boiler 170 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logano GB212 boiler 170 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logano GB212 boiler 170 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logano GB212 boiler 170 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logano GB212 boiler 170 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logano GB212 boiler 170 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logano GB212 boiler 170 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logano GB212 boiler 170 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logano GB212 boiler 170 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logano GB212 boiler 170 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logano GB212 boiler 170 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logano GB212 boiler 170 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logano GB212 boiler 170 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logano GB212 boiler 170 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logano GB212 boiler 170 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logano GB212 boiler 170 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logano GB212 boiler 170 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logano GB212 boiler 170 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logano GB212 boiler 170 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logano GB212 boiler 170 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logano GB212 boiler 170 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logano GB212 boiler 170 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logano GB212 boiler 170 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logano GB212 boiler 170 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logano GB212 boiler 170 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logano GB212 boiler 170 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logano GB212 boiler 170 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logano GB212 boiler 170 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logano GB212 boiler 170 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logano GB212 boiler 170 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logano GB212 boiler 170 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logano GB212 boiler 170 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logano GB212 boiler 170 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logano GB212 boiler 170 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logano GB212 boiler 170 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logano GB212 boiler 170 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logano GB212 boiler 170 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logano GB212 boiler 170 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logano GB212 boiler 170 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logano GB212 boiler 170 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logano GB212 boiler 170 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logano GB212 boiler 170 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logano GB212 boiler 170 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logano GB212 boiler 170 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logano GB212 boiler 170 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logano GB212 boiler 170 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logano GB212 boiler 170 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logano GB212 boiler 170 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logano GB212 boiler 170 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logano GB212 boiler 170 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logano GB212 boiler 170 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logano GB212 boiler 170 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logano GB212 boiler 170 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logano GB212 boiler 170 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logano GB212 boiler 170 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logano GB212 boiler 170 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logano GB212 boiler 170 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logano GB212 boiler 170 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logano GB212 boiler 170 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logano GB212 boiler 170 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logano GB212 boiler 170 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logano GB212 boiler 170 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logano GB212 boiler 170 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logano GB212 boiler 170 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logano GB212 boiler 170 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logano GB212 boiler 170 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logano GB212 boiler 170 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logano GB212 boiler 170 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logano GB212 boiler 170 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logano GB212 boiler 170 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logano GB212 boiler 170 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logano GB212 boiler 170 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logano GB212 boiler 170 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logano GB212 boiler 170 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logano GB212 boiler 170 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logano GB212 boiler 170 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logano GB212 boiler 170 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logano GB212 boiler 170 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logano GB212 boiler 170 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logano GB212 boiler 170 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logano GB212 boiler 170 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.nrg energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrg 5 9 1/100 0 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat 5 0 1/100 85 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgcool energy cooling uint24 (>=0<=167772) kWh False sensor.boiler_energy_cooling sensor.boiler_nrgcool 5 0 1/100 87 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal 5 0 1/100 89 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp 5 0 1/100 91 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat 5 0 1/100 93 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/100 95 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 metercool meter cooling uint24 (>=0<=167772) kWh False sensor.boiler_meter_cooling sensor.boiler_metercool 5 0 1/100 97 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.meter meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/100 2 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal 5 0 1/60 99 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol 5 0 1/60 101 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating 5 0 1/60 103 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling 5 0 1/60 105 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.uptimecomp operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecomp 5 9 1/60 4 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool 5 0 1/60 107 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 totalcompstarts total compressor control starts uint24 (>=0<=16777214) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts 5 0 1 109 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatingstarts heating control starts uint24 (>=0<=16777214) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts 5 0 1 111 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 coolingstarts cooling control starts uint24 (>=0<=16777214) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts 5 0 1 113 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.startshp starts hp uint24 (>=0<=16777214) False sensor.boiler_dhw_starts_hp sensor.boiler_dhw_startshp 5 9 1 6 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 poolstarts pool control starts uint24 (>=0<=16777214) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts 5 0 1 115 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgconstotal total energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal 5 0 1 117 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal 5 0 1 119 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating 5 0 1 121 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.nrgconscomp energy consumption compressor uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscomp 5 9 1 8 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling 5 0 1 123 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool 5 0 1 125 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal 5 0 1 127 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777214) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating 5 0 1 129 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.auxelecheatnrgcons aux elec. heater energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgcons 5 9 1 10 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777214) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool 5 0 1 131 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgsupptotal total energy supplied uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal 5 0 1 133 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgsuppheating total energy supplied heating uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating 5 0 1 135 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.nrgsupp total energy warm supplied uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsupp 5 9 1 12 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling 5 0 1 137 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 nrgsupppool total energy supplied pool uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool 5 0 1 139 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hppower compressor power output uint16 (>=0<=3199) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower 5 0 1/10 141 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower 5 0 1 142 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pvmaxcomp pv compressor max power uint8 (>=0<=25) kW True number.boiler_pv_compressor_max_power number.boiler_pvmaxcomp 5 0 1/10 143 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 powerreduction power reduction uint8 (>=30<=60) % True number.boiler_power_reduction number.boiler_powerreduction 5 0 10 144 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpsetdiffpress set differential pressure uint8 (>=150<=750) mbar True number.boiler_set_differential_pressure number.boiler_hpsetdiffpress 5 0 50 145 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon 5 0 1 146 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpactivity compressor activity enum [off|heating|cooling|hot water|pool|pool heating|defrost|compressor alarm] False sensor.boiler_compressor_activity sensor.boiler_hpactivity 5 0 1 147 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd 5 0 1 148 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve 5 0 1 149 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd 5 0 1 150 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd 5 0 1 151 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein 5 0 1/10 152 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout 5 0 1/10 153 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0 5 0 1/10 154 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1 5 0 1/10 155 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3 5 0 1/10 156 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1 5 0 1/10 157 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3 5 0 1/10 158 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4 5 0 1/10 159 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5 5 0 1/10 160 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6 5 0 1/10 161 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7 5 0 1/10 162 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2 5 0 1/10 163 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1 5 0 1/10 164 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1 5 0 1/10 165 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4 5 0 1/10 166 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1 5 0 1/10 167 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp 5 0 1/2 168 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way 5 0 1 169 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin1 input 1 state boolean False binary_sensor.boiler_input_1_state binary_sensor.boiler_hpin1 5 0 1 170 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt 5 0 1 171 8
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin2 input 2 state boolean False binary_sensor.boiler_input_2_state binary_sensor.boiler_hpin2 5 0 1 179 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt 5 0 1 180 8
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin3 input 3 state boolean False binary_sensor.boiler_input_3_state binary_sensor.boiler_hpin3 5 0 1 188 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt 5 0 1 189 8
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin4 input 4 state boolean False binary_sensor.boiler_input_4_state binary_sensor.boiler_hpin4 5 0 1 197 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt 5 0 1 198 8
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 maxheatcomp heat limit compressor enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp 5 0 1 206 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 maxheatheat heat limit heating enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat 5 0 1 207 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.maxheat heat limit enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheat 5 9 1 14 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheatersource aux heater source enum [not installed|electric heater|exclusive|parallel|hybrid] True select.boiler_aux_heater_source select.boiler_auxheatersource 5 0 1 208 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling 5 0 1 209 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly 5 0 1 210 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff 5 0 1 211 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheaterstatus aux heater status enum [off|heating|cooling|hot water|pool|pool heating|defrost|compressor alarm] False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus 5 0 1 212 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheaterlevel aux heater level uint8 (>=0<=100) % False sensor.boiler_aux_heater_level sensor.boiler_auxheaterlevel 5 0 1 213 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay 5 0 10 214 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit 5 0 1/10 215 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart 5 0 1/10 216 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode 5 0 1 217 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat 5 0 5 218 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool 5 0 5 219 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool 5 0 5 220 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode 5 0 1 221 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom 5 0 15 222 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto 5 0 15 223 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent 5 0 1 224 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode 5 0 1 225 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix 5 0 1 226 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat 5 0 1/10 227 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool 5 0 1/10 228 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling 5 0 1 229 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable 5 0 1 230 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve 5 0 1 231 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump 5 0 1 232 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod 5 0 1 233 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way 5 0 1 234 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1 5 0 1 235 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2 5 0 1 236 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3 5 0 1 237 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0 5 0 1 238 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode 5 0 1 239 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan 5 0 1 240 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 shutdown shutdown cmd [off|on] True sensor.boiler_shutdown sensor.boiler_shutdown 5 0 1 241 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hpcurrpower compressor current power uint16 (>=0<=31999) W False sensor.boiler_compressor_current_power sensor.boiler_hpcurrpower 5 0 1 242 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 hppowerlimit power limit uint16 (>=0<=31999) W True number.boiler_power_limit number.boiler_hppowerlimit 5 0 1 243 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop 5 9 1 15 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat 5 9 1 16 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.altopprio prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altopprio 5 9 1 17 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff 5 9 1 18 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff 5 9 1 19 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff 5 9 1 20 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.comfdiff comfort diff uint8 (>=4<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff 5 9 1 21 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.ecodiff eco diff uint8 (>=4<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff 5 9 1 22 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff 5 9 1 23 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop 5 9 1 24 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop 5 9 1 25 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop 5 9 1 26 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.hpcircpump circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpump 5 9 1 27 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Enviline, Compress 6000AW, Hybrid 3000-7000iAW, SupraEco/Geo 5xx, WLW196i/WSW196i boiler 172 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Geo 5xx boiler 173 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Geo 5xx boiler 173 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Geo 5xx boiler 173 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Geo 5xx boiler 173 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Geo 5xx boiler 173 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Geo 5xx boiler 173 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Geo 5xx boiler 173 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Geo 5xx boiler 173 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Geo 5xx boiler 173 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Geo 5xx boiler 173 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Geo 5xx boiler 173 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Geo 5xx boiler 173 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Geo 5xx boiler 173 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Geo 5xx boiler 173 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Geo 5xx boiler 173 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Geo 5xx boiler 173 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Geo 5xx boiler 173 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Geo 5xx boiler 173 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Geo 5xx boiler 173 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Geo 5xx boiler 173 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Geo 5xx boiler 173 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Geo 5xx boiler 173 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Geo 5xx boiler 173 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Geo 5xx boiler 173 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Geo 5xx boiler 173 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Geo 5xx boiler 173 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Geo 5xx boiler 173 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Geo 5xx boiler 173 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Geo 5xx boiler 173 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Geo 5xx boiler 173 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Geo 5xx boiler 173 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Geo 5xx boiler 173 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Geo 5xx boiler 173 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Geo 5xx boiler 173 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Geo 5xx boiler 173 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Geo 5xx boiler 173 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Geo 5xx boiler 173 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Geo 5xx boiler 173 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Geo 5xx boiler 173 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Geo 5xx boiler 173 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Geo 5xx boiler 173 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Geo 5xx boiler 173 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Geo 5xx boiler 173 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Geo 5xx boiler 173 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Geo 5xx boiler 173 dhw.nrg energy uint24 (>=0<=167772) kWh False sensor.boiler_dhw_energy sensor.boiler_dhw_nrg 5 9 1/100 0 2
Geo 5xx boiler 173 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.boiler_energy_heating sensor.boiler_nrgheat 5 0 1/100 85 2
Geo 5xx boiler 173 nrgcool energy cooling uint24 (>=0<=167772) kWh False sensor.boiler_energy_cooling sensor.boiler_nrgcool 5 0 1/100 87 2
Geo 5xx boiler 173 metertotal meter total uint24 (>=0<=167772) kWh False sensor.boiler_meter_total sensor.boiler_metertotal 5 0 1/100 89 2
Geo 5xx boiler 173 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.boiler_meter_compressor sensor.boiler_metercomp 5 0 1/100 91 2
Geo 5xx boiler 173 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.boiler_meter_e-heater sensor.boiler_metereheat 5 0 1/100 93 2
Geo 5xx boiler 173 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/100 95 2
Geo 5xx boiler 173 metercool meter cooling uint24 (>=0<=167772) kWh False sensor.boiler_meter_cooling sensor.boiler_metercool 5 0 1/100 97 2
Geo 5xx boiler 173 dhw.meter meter uint24 (>=0<=167772) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/100 2 2
Geo 5xx boiler 173 uptimetotal heatpump total uptime time (>=0<=279620) minutes False sensor.boiler_heatpump_total_uptime sensor.boiler_uptimetotal 5 0 1/60 99 2
Geo 5xx boiler 173 uptimecontrol total operating time heat time (>=0<=279620) minutes False sensor.boiler_total_operating_time_heat sensor.boiler_uptimecontrol 5 0 1/60 101 2
Geo 5xx boiler 173 uptimecompheating operating time compressor heating time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_heating sensor.boiler_uptimecompheating 5 0 1/60 103 2
Geo 5xx boiler 173 uptimecompcooling operating time compressor cooling time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_cooling sensor.boiler_uptimecompcooling 5 0 1/60 105 2
Geo 5xx boiler 173 dhw.uptimecomp operating time compressor time (>=0<=279620) minutes False sensor.boiler_dhw_operating_time_compressor sensor.boiler_dhw_uptimecomp 5 9 1/60 4 2
Geo 5xx boiler 173 uptimecomppool operating time compressor pool time (>=0<=279620) minutes False sensor.boiler_operating_time_compressor_pool sensor.boiler_uptimecomppool 5 0 1/60 107 2
Geo 5xx boiler 173 totalcompstarts total compressor control starts uint24 (>=0<=16777214) False sensor.boiler_total_compressor_control_starts sensor.boiler_totalcompstarts 5 0 1 109 2
Geo 5xx boiler 173 heatingstarts heating control starts uint24 (>=0<=16777214) False sensor.boiler_heating_control_starts sensor.boiler_heatingstarts 5 0 1 111 2
Geo 5xx boiler 173 coolingstarts cooling control starts uint24 (>=0<=16777214) False sensor.boiler_cooling_control_starts sensor.boiler_coolingstarts 5 0 1 113 2
Geo 5xx boiler 173 dhw.startshp starts hp uint24 (>=0<=16777214) False sensor.boiler_dhw_starts_hp sensor.boiler_dhw_startshp 5 9 1 6 2
Geo 5xx boiler 173 poolstarts pool control starts uint24 (>=0<=16777214) False sensor.boiler_pool_control_starts sensor.boiler_poolstarts 5 0 1 115 2
Geo 5xx boiler 173 nrgconstotal total energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_consumption sensor.boiler_nrgconstotal 5 0 1 117 2
Geo 5xx boiler 173 nrgconscomptotal total energy consumption compressor uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_consumption_compressor sensor.boiler_nrgconscomptotal 5 0 1 119 2
Geo 5xx boiler 173 nrgconscompheating energy consumption compressor heating uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_heating sensor.boiler_nrgconscompheating 5 0 1 121 2
Geo 5xx boiler 173 dhw.nrgconscomp energy consumption compressor uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_energy_consumption_compressor sensor.boiler_dhw_nrgconscomp 5 9 1 8 2
Geo 5xx boiler 173 nrgconscompcooling energy consumption compressor cooling uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_cooling sensor.boiler_nrgconscompcooling 5 0 1 123 2
Geo 5xx boiler 173 nrgconscomppool energy consumption compressor pool uint24 (>=0<=16777214) kWh False sensor.boiler_energy_consumption_compressor_pool sensor.boiler_nrgconscomppool 5 0 1 125 2
Geo 5xx boiler 173 auxelecheatnrgconstotal total aux elec. heater energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_total_aux_elec._heater_energy_consumption sensor.boiler_auxelecheatnrgconstotal 5 0 1 127 2
Geo 5xx boiler 173 auxelecheatnrgconsheating aux elec. heater energy consumption heating uint24 (>=0<=16777214) kWh False sensor.boiler_aux_elec._heater_energy_consumption_heating sensor.boiler_auxelecheatnrgconsheating 5 0 1 129 2
Geo 5xx boiler 173 dhw.auxelecheatnrgcons aux elec. heater energy consumption uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_aux_elec._heater_energy_consumption sensor.boiler_dhw_auxelecheatnrgcons 5 9 1 10 2
Geo 5xx boiler 173 auxelecheatnrgconspool aux elec. heater energy consumption pool uint24 (>=0<=16777214) kWh False sensor.boiler_aux_elec._heater_energy_consumption_pool sensor.boiler_auxelecheatnrgconspool 5 0 1 131 2
Geo 5xx boiler 173 nrgsupptotal total energy supplied uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied sensor.boiler_nrgsupptotal 5 0 1 133 2
Geo 5xx boiler 173 nrgsuppheating total energy supplied heating uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_heating sensor.boiler_nrgsuppheating 5 0 1 135 2
Geo 5xx boiler 173 dhw.nrgsupp total energy warm supplied uint24 (>=0<=16777214) kWh False sensor.boiler_dhw_total_energy_warm_supplied sensor.boiler_dhw_nrgsupp 5 9 1 12 2
Geo 5xx boiler 173 nrgsuppcooling total energy supplied cooling uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_cooling sensor.boiler_nrgsuppcooling 5 0 1 137 2
Geo 5xx boiler 173 nrgsupppool total energy supplied pool uint24 (>=0<=16777214) kWh False sensor.boiler_total_energy_supplied_pool sensor.boiler_nrgsupppool 5 0 1 139 2
Geo 5xx boiler 173 hppower compressor power output uint16 (>=0<=3199) kW False sensor.boiler_compressor_power_output sensor.boiler_hppower 5 0 1/10 141 1
Geo 5xx boiler 173 hpmaxpower compressor max power uint8 (>=0<=100) % True number.boiler_compressor_max_power number.boiler_hpmaxpower 5 0 1 142 1
Geo 5xx boiler 173 pvmaxcomp pv compressor max power uint8 (>=0<=25) kW True number.boiler_pv_compressor_max_power number.boiler_pvmaxcomp 5 0 1/10 143 1
Geo 5xx boiler 173 powerreduction power reduction uint8 (>=30<=60) % True number.boiler_power_reduction number.boiler_powerreduction 5 0 10 144 1
Geo 5xx boiler 173 hpsetdiffpress set differential pressure uint8 (>=150<=750) mbar True number.boiler_set_differential_pressure number.boiler_hpsetdiffpress 5 0 50 145 1
Geo 5xx boiler 173 hpcompon hp compressor boolean False binary_sensor.boiler_hp_compressor binary_sensor.boiler_hpcompon 5 0 1 146 1
Geo 5xx boiler 173 hpactivity compressor activity enum [off|heating|cooling|hot water|pool|pool heating|defrost|compressor alarm] False sensor.boiler_compressor_activity sensor.boiler_hpactivity 5 0 1 147 1
Geo 5xx boiler 173 hpbrinepumpspd brine pump speed uint8 (>=0<=100) % False sensor.boiler_brine_pump_speed sensor.boiler_hpbrinepumpspd 5 0 1 148 1
Geo 5xx boiler 173 hpswitchvalve switch valve boolean False binary_sensor.boiler_switch_valve binary_sensor.boiler_hpswitchvalve 5 0 1 149 1
Geo 5xx boiler 173 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.boiler_compressor_speed sensor.boiler_hpcompspd 5 0 1 150 1
Geo 5xx boiler 173 hpcircspd circulation pump speed uint8 (>=0<=100) % False sensor.boiler_circulation_pump_speed sensor.boiler_hpcircspd 5 0 1 151 1
Geo 5xx boiler 173 hpbrinein brine in/evaporator int16 (>=-3199<=3199) C False sensor.boiler_brine_in/evaporator sensor.boiler_hpbrinein 5 0 1/10 152 1
Geo 5xx boiler 173 hpbrineout brine out/condenser int16 (>=-3199<=3199) C False sensor.boiler_brine_out/condenser sensor.boiler_hpbrineout 5 0 1/10 153 1
Geo 5xx boiler 173 hptc0 heat carrier return (TC0) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_return_(TC0) sensor.boiler_hptc0 5 0 1/10 154 1
Geo 5xx boiler 173 hptc1 heat carrier forward (TC1) int16 (>=-3199<=3199) C False sensor.boiler_heat_carrier_forward_(TC1) sensor.boiler_hptc1 5 0 1/10 155 1
Geo 5xx boiler 173 hptc3 condenser temperature (TC3) int16 (>=-3199<=3199) C False sensor.boiler_condenser_temperature_(TC3) sensor.boiler_hptc3 5 0 1/10 156 1
Geo 5xx boiler 173 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.boiler_compressor_temperature_(TR1) sensor.boiler_hptr1 5 0 1/10 157 1
Geo 5xx boiler 173 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.boiler_hptr3 5 0 1/10 158 1
Geo 5xx boiler 173 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.boiler_evaporator_inlet_temperature_(TR4) sensor.boiler_hptr4 5 0 1/10 159 1
Geo 5xx boiler 173 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.boiler_compressor_inlet_temperature_(TR5) sensor.boiler_hptr5 5 0 1/10 160 1
Geo 5xx boiler 173 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.boiler_compressor_outlet_temperature_(TR6) sensor.boiler_hptr6 5 0 1/10 161 1
Geo 5xx boiler 173 hptr7 refrigerant temperature gas side (condenser input) (TR7) int16 (>=-3199<=3199) C False sensor.boiler_refrigerant_temperature_gas_side_(condenser_input)_(TR7) sensor.boiler_hptr7 5 0 1/10 162 1
Geo 5xx boiler 173 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.boiler_air_inlet_temperature_(TL2) sensor.boiler_hptl2 5 0 1/10 163 1
Geo 5xx boiler 173 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.boiler_low_pressure_side_temperature_(PL1) sensor.boiler_hppl1 5 0 1/10 164 1
Geo 5xx boiler 173 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.boiler_high_pressure_side_temperature_(PH1) sensor.boiler_hpph1 5 0 1/10 165 1
Geo 5xx boiler 173 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.boiler_drain_pan_temp_(TA4) sensor.boiler_hpta4 5 0 1/10 166 1
Geo 5xx boiler 173 hptw1 reservoir temp (TW1) int16 (>=-3199<=3199) C False sensor.boiler_reservoir_temp_(TW1) sensor.boiler_hptw1 5 0 1/10 167 1
Geo 5xx boiler 173 poolsettemp pool set temperature uint8 (>=0<=127) C True number.boiler_pool_set_temperature number.boiler_poolsettemp 5 0 1/2 168 1
Geo 5xx boiler 173 hp4way 4-way valve (VR4) enum [cooling & defrost|heating & dhw] False sensor.boiler_4-way_valve_(VR4) sensor.boiler_hp4way 5 0 1 169 1
Geo 5xx boiler 173 hpin1 input 1 state boolean False binary_sensor.boiler_input_1_state binary_sensor.boiler_hpin1 5 0 1 170 1
Geo 5xx boiler 173 hpin1opt input 1 options string True sensor.boiler_input_1_options sensor.boiler_hpin1opt 5 0 1 171 8
Geo 5xx boiler 173 hpin2 input 2 state boolean False binary_sensor.boiler_input_2_state binary_sensor.boiler_hpin2 5 0 1 179 1
Geo 5xx boiler 173 hpin2opt input 2 options string True sensor.boiler_input_2_options sensor.boiler_hpin2opt 5 0 1 180 8
Geo 5xx boiler 173 hpin3 input 3 state boolean False binary_sensor.boiler_input_3_state binary_sensor.boiler_hpin3 5 0 1 188 1
Geo 5xx boiler 173 hpin3opt input 3 options string True sensor.boiler_input_3_options sensor.boiler_hpin3opt 5 0 1 189 8
Geo 5xx boiler 173 hpin4 input 4 state boolean False binary_sensor.boiler_input_4_state binary_sensor.boiler_hpin4 5 0 1 197 1
Geo 5xx boiler 173 hpin4opt input 4 options string True sensor.boiler_input_4_options sensor.boiler_hpin4opt 5 0 1 198 8
Geo 5xx boiler 173 maxheatcomp heat limit compressor enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_compressor select.boiler_maxheatcomp 5 0 1 206 1
Geo 5xx boiler 173 maxheatheat heat limit heating enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_heat_limit_heating select.boiler_maxheatheat 5 0 1 207 1
Geo 5xx boiler 173 dhw.maxheat heat limit enum [0 kW|2 kW|3 kW|4 kW|6 kW|9 kW] True select.boiler_dhw_heat_limit select.boiler_dhw_maxheat 5 9 1 14 1
Geo 5xx boiler 173 auxheatersource aux heater source enum [not installed|electric heater|exclusive|parallel|hybrid] True select.boiler_aux_heater_source select.boiler_auxheatersource 5 0 1 208 1
Geo 5xx boiler 173 pvcooling cooling only with PV boolean True switch.boiler_cooling_only_with_PV switch.boiler_pvcooling 5 0 1 209 1
Geo 5xx boiler 173 auxheateronly aux heater only boolean True switch.boiler_aux_heater_only switch.boiler_auxheateronly 5 0 1 210 1
Geo 5xx boiler 173 auxheateroff disable aux heater boolean True switch.boiler_disable_aux_heater switch.boiler_auxheateroff 5 0 1 211 1
Geo 5xx boiler 173 auxheaterstatus aux heater status enum [off|heating|cooling|hot water|pool|pool heating|defrost|compressor alarm] False sensor.boiler_aux_heater_status sensor.boiler_auxheaterstatus 5 0 1 212 1
Geo 5xx boiler 173 auxheaterlevel aux heater level uint8 (>=0<=100) % False sensor.boiler_aux_heater_level sensor.boiler_auxheaterlevel 5 0 1 213 1
Geo 5xx boiler 173 auxheaterdelay aux heater on delay uint16 (>=10<=1000) K*min True number.boiler_aux_heater_on_delay number.boiler_auxheaterdelay 5 0 10 214 1
Geo 5xx boiler 173 auxmaxlimit aux heater max limit uint8 (>=0<=10) K True number.boiler_aux_heater_max_limit number.boiler_auxmaxlimit 5 0 1/10 215 1
Geo 5xx boiler 173 auxlimitstart aux heater limit start uint8 (>=0<=10) K True number.boiler_aux_heater_limit_start number.boiler_auxlimitstart 5 0 1/10 216 1
Geo 5xx boiler 173 auxheatrmode aux heater mode enum [eco|comfort] True select.boiler_aux_heater_mode select.boiler_auxheatrmode 5 0 1 217 1
Geo 5xx boiler 173 hphystheat on/off hyst heat uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_heat number.boiler_hphystheat 5 0 5 218 1
Geo 5xx boiler 173 hphystcool on/off hyst cool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_cool number.boiler_hphystcool 5 0 5 219 1
Geo 5xx boiler 173 hphystpool on/off hyst pool uint16 (>=50<=1500) K*min True number.boiler_on/off_hyst_pool number.boiler_hphystpool 5 0 5 220 1
Geo 5xx boiler 173 silentmode silent mode enum [off|auto|on] True select.boiler_silent_mode select.boiler_silentmode 5 0 1 221 1
Geo 5xx boiler 173 silentfrom silent mode from uint8 (>=0<=3810) minutes True number.boiler_silent_mode_from number.boiler_silentfrom 5 0 15 222 1
Geo 5xx boiler 173 silentto silent mode to uint8 (>=0<=3810) minutes True number.boiler_silent_mode_to number.boiler_silentto 5 0 15 223 1
Geo 5xx boiler 173 mintempsilent min outside temp for silent mode int8 (>=-126<=126) C True number.boiler_min_outside_temp_for_silent_mode number.boiler_mintempsilent 5 0 1 224 1
Geo 5xx boiler 173 tempparmode outside temp parallel mode int8 (>=-126<=126) C True number.boiler_outside_temp_parallel_mode number.boiler_tempparmode 5 0 1 225 1
Geo 5xx boiler 173 auxheatmix aux heater mixing valve int8 (>=-100<=100) % False sensor.boiler_aux_heater_mixing_valve sensor.boiler_auxheatmix 5 0 1 226 1
Geo 5xx boiler 173 tempdiffheat temp diff TC3/TC0 heat uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_heat number.boiler_tempdiffheat 5 0 1/10 227 1
Geo 5xx boiler 173 tempdiffcool temp diff TC3/TC0 cool uint8 (>=2<=10) K True number.boiler_temp_diff_TC3/TC0_cool number.boiler_tempdiffcool 5 0 1/10 228 1
Geo 5xx boiler 173 vpcooling valve/pump cooling boolean True switch.boiler_valve/pump_cooling switch.boiler_vpcooling 5 0 1 229 1
Geo 5xx boiler 173 heatcable heating cable boolean True switch.boiler_heating_cable switch.boiler_heatcable 5 0 1 230 1
Geo 5xx boiler 173 vc0valve VC0 valve boolean True switch.boiler_VC0_valve switch.boiler_vc0valve 5 0 1 231 1
Geo 5xx boiler 173 primepump primary heatpump boolean True switch.boiler_primary_heatpump switch.boiler_primepump 5 0 1 232 1
Geo 5xx boiler 173 primepumpmod primary heatpump modulation uint8 (>=0<=100) % True number.boiler_primary_heatpump_modulation number.boiler_primepumpmod 5 0 1 233 1
Geo 5xx boiler 173 hp3way 3-way valve boolean True switch.boiler_3-way_valve switch.boiler_hp3way 5 0 1 234 1
Geo 5xx boiler 173 elheatstep1 el. heater step 1 boolean True switch.boiler_el._heater_step_1 switch.boiler_elheatstep1 5 0 1 235 1
Geo 5xx boiler 173 elheatstep2 el. heater step 2 boolean True switch.boiler_el._heater_step_2 switch.boiler_elheatstep2 5 0 1 236 1
Geo 5xx boiler 173 elheatstep3 el. heater step 3 boolean True switch.boiler_el._heater_step_3 switch.boiler_elheatstep3 5 0 1 237 1
Geo 5xx boiler 173 hpea0 condensate reservoir heating (EA0) boolean False binary_sensor.boiler_condensate_reservoir_heating_(EA0) binary_sensor.boiler_hpea0 5 0 1 238 1
Geo 5xx boiler 173 hppumpmode primary heatpump mode enum [auto|continuous] True select.boiler_primary_heatpump_mode select.boiler_hppumpmode 5 0 1 239 1
Geo 5xx boiler 173 fan fan uint8 (>=20<=100) % True number.boiler_fan number.boiler_fan 5 0 1 240 1
Geo 5xx boiler 173 shutdown shutdown cmd [off|on] True sensor.boiler_shutdown sensor.boiler_shutdown 5 0 1 241 1
Geo 5xx boiler 173 hpcurrpower compressor current power uint16 (>=0<=31999) W False sensor.boiler_compressor_current_power sensor.boiler_hpcurrpower 5 0 1 242 1
Geo 5xx boiler 173 hppowerlimit power limit uint16 (>=0<=31999) W True number.boiler_power_limit number.boiler_hppowerlimit 5 0 1 243 1
Geo 5xx boiler 173 dhw.alternatingop alternating operation boolean True switch.boiler_dhw_alternating_operation switch.boiler_dhw_alternatingop 5 9 1 15 1
Geo 5xx boiler 173 dhw.altopprioheat prioritise heating during dhw uint8 (>=20<=120) minutes True number.boiler_dhw_prioritise_heating_during_dhw number.boiler_dhw_altopprioheat 5 9 1 16 1
Geo 5xx boiler 173 dhw.altopprio prioritise dhw during heating uint8 (>=30<=120) minutes True number.boiler_dhw_prioritise_dhw_during_heating number.boiler_dhw_altopprio 5 9 1 17 1
Geo 5xx boiler 173 dhw.comfoff comfort switch off uint8 (>=15<=65) C True number.boiler_dhw_comfort_switch_off number.boiler_dhw_comfoff 5 9 1 18 1
Geo 5xx boiler 173 dhw.ecooff eco switch off uint8 (>=15<=65) C True number.boiler_dhw_eco_switch_off number.boiler_dhw_ecooff 5 9 1 19 1
Geo 5xx boiler 173 dhw.ecoplusoff eco+ switch off uint8 (>=48<=63) C True number.boiler_dhw_eco+_switch_off number.boiler_dhw_ecoplusoff 5 9 1 20 1
Geo 5xx boiler 173 dhw.comfdiff comfort diff uint8 (>=4<=12) K True number.boiler_dhw_comfort_diff number.boiler_dhw_comfdiff 5 9 1 21 1
Geo 5xx boiler 173 dhw.ecodiff eco diff uint8 (>=4<=12) K True number.boiler_dhw_eco_diff number.boiler_dhw_ecodiff 5 9 1 22 1
Geo 5xx boiler 173 dhw.ecoplusdiff eco+ diff uint8 (>=6<=12) K True number.boiler_dhw_eco+_diff number.boiler_dhw_ecoplusdiff 5 9 1 23 1
Geo 5xx boiler 173 dhw.comfstop comfort stop temp uint8 (>=0<=254) C True number.boiler_dhw_comfort_stop_temp number.boiler_dhw_comfstop 5 9 1 24 1
Geo 5xx boiler 173 dhw.ecostop eco stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco_stop_temp number.boiler_dhw_ecostop 5 9 1 25 1
Geo 5xx boiler 173 dhw.ecoplusstop eco+ stop temp uint8 (>=0<=254) C True number.boiler_dhw_eco+_stop_temp number.boiler_dhw_ecoplusstop 5 9 1 26 1
Geo 5xx boiler 173 dhw.hpcircpump circulation pump available during dhw boolean True switch.boiler_dhw_circulation_pump_available_during_dhw switch.boiler_dhw_hpcircpump 5 9 1 27 1
Geo 5xx boiler 173 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Geo 5xx boiler 173 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Geo 5xx boiler 173 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Geo 5xx boiler 173 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Geo 5xx boiler 173 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Geo 5xx boiler 173 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Geo 5xx boiler 173 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Geo 5xx boiler 173 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Geo 5xx boiler 173 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Geo 5xx boiler 173 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Geo 5xx boiler 173 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Geo 5xx boiler 173 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Geo 5xx boiler 173 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Geo 5xx boiler 173 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Geo 5xx boiler 173 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Geo 5xx boiler 173 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Geo 5xx boiler 173 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Geo 5xx boiler 173 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Geo 5xx boiler 173 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Geo 5xx boiler 173 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Geo 5xx boiler 173 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Geo 5xx boiler 173 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Geo 5xx boiler 173 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Geo 5xx boiler 173 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Geo 5xx boiler 173 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Geo 5xx boiler 173 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Geo 5xx boiler 173 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Geo 5xx boiler 173 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Geo 5xx boiler 173 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Geo 5xx boiler 173 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Geo 5xx boiler 173 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Geo 5xx boiler 173 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Geo 5xx boiler 173 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Geo 5xx boiler 173 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Geo 5xx boiler 173 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Geo 5xx boiler 173 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Geo 5xx boiler 173 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Geo 5xx boiler 173 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Geo 5xx boiler 173 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Geo 5xx boiler 173 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Condens 5000i, Greenstar 8000/GC9800IW, GB192i*2 boiler 195 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logamax U122, Cerapur boiler 203 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logamax U122, Cerapur boiler 203 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logamax U122, Cerapur boiler 203 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logamax U122, Cerapur boiler 203 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logamax U122, Cerapur boiler 203 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logamax U122, Cerapur boiler 203 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logamax U122, Cerapur boiler 203 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logamax U122, Cerapur boiler 203 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logamax U122, Cerapur boiler 203 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logamax U122, Cerapur boiler 203 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logamax U122, Cerapur boiler 203 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logamax U122, Cerapur boiler 203 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logamax U122, Cerapur boiler 203 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logamax U122, Cerapur boiler 203 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logamax U122, Cerapur boiler 203 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logamax U122, Cerapur boiler 203 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logamax U122, Cerapur boiler 203 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logamax U122, Cerapur boiler 203 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logamax U122, Cerapur boiler 203 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logamax U122, Cerapur boiler 203 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logamax U122, Cerapur boiler 203 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logamax U122, Cerapur boiler 203 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logamax U122, Cerapur boiler 203 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logamax U122, Cerapur boiler 203 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logamax U122, Cerapur boiler 203 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logamax U122, Cerapur boiler 203 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logamax U122, Cerapur boiler 203 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logamax U122, Cerapur boiler 203 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logamax U122, Cerapur boiler 203 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logamax U122, Cerapur boiler 203 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logamax U122, Cerapur boiler 203 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logamax U122, Cerapur boiler 203 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logamax U122, Cerapur boiler 203 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logamax U122, Cerapur boiler 203 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logamax U122, Cerapur boiler 203 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logamax U122, Cerapur boiler 203 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logamax U122, Cerapur boiler 203 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logamax U122, Cerapur boiler 203 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logamax U122, Cerapur boiler 203 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logamax U122, Cerapur boiler 203 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logamax U122, Cerapur boiler 203 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logamax U122, Cerapur boiler 203 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logamax U122, Cerapur boiler 203 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logamax U122, Cerapur boiler 203 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logamax U122, Cerapur boiler 203 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logamax U122, Cerapur boiler 203 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logamax U122, Cerapur boiler 203 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logamax U122, Cerapur boiler 203 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logamax U122, Cerapur boiler 203 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logamax U122, Cerapur boiler 203 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logamax U122, Cerapur boiler 203 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logamax U122, Cerapur boiler 203 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logamax U122, Cerapur boiler 203 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logamax U122, Cerapur boiler 203 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logamax U122, Cerapur boiler 203 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logamax U122, Cerapur boiler 203 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logamax U122, Cerapur boiler 203 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logamax U122, Cerapur boiler 203 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logamax U122, Cerapur boiler 203 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logamax U122, Cerapur boiler 203 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logamax U122, Cerapur boiler 203 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logamax U122, Cerapur boiler 203 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logamax U122, Cerapur boiler 203 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logamax U122, Cerapur boiler 203 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logamax U122, Cerapur boiler 203 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logamax U122, Cerapur boiler 203 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logamax U122, Cerapur boiler 203 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logamax U122, Cerapur boiler 203 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logamax U122, Cerapur boiler 203 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logamax U122, Cerapur boiler 203 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logamax U122, Cerapur boiler 203 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logamax U122, Cerapur boiler 203 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logamax U122, Cerapur boiler 203 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logamax U122, Cerapur boiler 203 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logamax U122, Cerapur boiler 203 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logamax U122, Cerapur boiler 203 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logamax U122, Cerapur boiler 203 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logamax U122, Cerapur boiler 203 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logamax U122, Cerapur boiler 203 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logamax U122, Cerapur boiler 203 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logamax U122, Cerapur boiler 203 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logamax U122, Cerapur boiler 203 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logamax U122, Cerapur boiler 203 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logamax U122, Cerapur boiler 203 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logamax U122, Cerapur boiler 203 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logamax U122, Cerapur boiler 203 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logamax U122, Cerapur boiler 203 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logamax U122, Cerapur boiler 203 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logamax U122, Cerapur boiler 203 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logamax U122, Cerapur boiler 203 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logamax U122, Cerapur boiler 203 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logamax U122, Cerapur boiler 203 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logamax U122, Cerapur boiler 203 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logamax U122, Cerapur boiler 203 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logamax U122, Cerapur boiler 203 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logamax U122, Cerapur boiler 203 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logamax U122, Cerapur boiler 203 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logamax U122, Cerapur boiler 203 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logamax U122, Cerapur boiler 203 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logamax U122, Cerapur boiler 203 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logamax U122, Cerapur boiler 203 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logamax U122, Cerapur boiler 203 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logamax U122, Cerapur boiler 203 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logamax U122, Cerapur boiler 203 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logamax U122, Cerapur boiler 203 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logamax U122, Cerapur boiler 203 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logamax U122, Cerapur boiler 203 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logamax U122, Cerapur boiler 203 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logamax U122, Cerapur boiler 203 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logamax U122, Cerapur boiler 203 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logamax U122, Cerapur boiler 203 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logamax U122, Cerapur boiler 203 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logamax U122, Cerapur boiler 203 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logamax U122, Cerapur boiler 203 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logamax U122, Cerapur boiler 203 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Ecomline Excellent boiler 206 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Ecomline Excellent boiler 206 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Ecomline Excellent boiler 206 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Ecomline Excellent boiler 206 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Ecomline Excellent boiler 206 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Ecomline Excellent boiler 206 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Ecomline Excellent boiler 206 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Ecomline Excellent boiler 206 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Ecomline Excellent boiler 206 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Ecomline Excellent boiler 206 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Ecomline Excellent boiler 206 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Ecomline Excellent boiler 206 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Ecomline Excellent boiler 206 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Ecomline Excellent boiler 206 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Ecomline Excellent boiler 206 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Ecomline Excellent boiler 206 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Ecomline Excellent boiler 206 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Ecomline Excellent boiler 206 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Ecomline Excellent boiler 206 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Ecomline Excellent boiler 206 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Ecomline Excellent boiler 206 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Ecomline Excellent boiler 206 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Ecomline Excellent boiler 206 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Ecomline Excellent boiler 206 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Ecomline Excellent boiler 206 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Ecomline Excellent boiler 206 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Ecomline Excellent boiler 206 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Ecomline Excellent boiler 206 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Ecomline Excellent boiler 206 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Ecomline Excellent boiler 206 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Ecomline Excellent boiler 206 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Ecomline Excellent boiler 206 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Ecomline Excellent boiler 206 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Ecomline Excellent boiler 206 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Ecomline Excellent boiler 206 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Ecomline Excellent boiler 206 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Ecomline Excellent boiler 206 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Ecomline Excellent boiler 206 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Ecomline Excellent boiler 206 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Ecomline Excellent boiler 206 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Ecomline Excellent boiler 206 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Ecomline Excellent boiler 206 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Ecomline Excellent boiler 206 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Ecomline Excellent boiler 206 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Ecomline Excellent boiler 206 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Ecomline Excellent boiler 206 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Ecomline Excellent boiler 206 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Ecomline Excellent boiler 206 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Ecomline Excellent boiler 206 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Ecomline Excellent boiler 206 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Ecomline Excellent boiler 206 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Ecomline Excellent boiler 206 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Ecomline Excellent boiler 206 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Ecomline Excellent boiler 206 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Ecomline Excellent boiler 206 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Ecomline Excellent boiler 206 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Ecomline Excellent boiler 206 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Ecomline Excellent boiler 206 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Ecomline Excellent boiler 206 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Ecomline Excellent boiler 206 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Ecomline Excellent boiler 206 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Ecomline Excellent boiler 206 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Ecomline Excellent boiler 206 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Ecomline Excellent boiler 206 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Ecomline Excellent boiler 206 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Ecomline Excellent boiler 206 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Ecomline Excellent boiler 206 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Ecomline Excellent boiler 206 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Ecomline Excellent boiler 206 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Ecomline Excellent boiler 206 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Ecomline Excellent boiler 206 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Ecomline Excellent boiler 206 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Ecomline Excellent boiler 206 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Ecomline Excellent boiler 206 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Ecomline Excellent boiler 206 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Ecomline Excellent boiler 206 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Ecomline Excellent boiler 206 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Ecomline Excellent boiler 206 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Ecomline Excellent boiler 206 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Ecomline Excellent boiler 206 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Ecomline Excellent boiler 206 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Ecomline Excellent boiler 206 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Ecomline Excellent boiler 206 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Ecomline Excellent boiler 206 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Ecomline Excellent boiler 206 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Ecomline Excellent boiler 206 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Ecomline Excellent boiler 206 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Ecomline Excellent boiler 206 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Ecomline Excellent boiler 206 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Ecomline Excellent boiler 206 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Ecomline Excellent boiler 206 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Ecomline Excellent boiler 206 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Ecomline Excellent boiler 206 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Ecomline Excellent boiler 206 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Ecomline Excellent boiler 206 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Ecomline Excellent boiler 206 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Ecomline Excellent boiler 206 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Ecomline Excellent boiler 206 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Ecomline Excellent boiler 206 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Ecomline Excellent boiler 206 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Ecomline Excellent boiler 206 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Ecomline Excellent boiler 206 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Ecomline Excellent boiler 206 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Ecomline Excellent boiler 206 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Ecomline Excellent boiler 206 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Ecomline Excellent boiler 206 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Ecomline Excellent boiler 206 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Ecomline Excellent boiler 206 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Ecomline Excellent boiler 206 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Ecomline Excellent boiler 206 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Ecomline Excellent boiler 206 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Ecomline Excellent boiler 206 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Ecomline Excellent boiler 206 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Ecomline Excellent boiler 206 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Ecomline Excellent boiler 206 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logamax Plus, GB192, Condens GC9000, Greenstar ErP boiler 208 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Cascade MC400 boiler 210 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Cascade MC400 boiler 210 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Cascade MC400 boiler 210 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Cascade MC400 boiler 210 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Cascade MC400 boiler 210 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Cascade MC400 boiler 210 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Cascade MC400 boiler 210 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Cascade MC400 boiler 210 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Cascade MC400 boiler 210 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Cascade MC400 boiler 210 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Cascade MC400 boiler 210 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Cascade MC400 boiler 210 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Cascade MC400 boiler 210 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Cascade MC400 boiler 210 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Cascade MC400 boiler 210 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Cascade MC400 boiler 210 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Cascade MC400 boiler 210 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Cascade MC400 boiler 210 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Cascade MC400 boiler 210 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Cascade MC400 boiler 210 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Cascade MC400 boiler 210 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Cascade MC400 boiler 210 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Cascade MC400 boiler 210 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Cascade MC400 boiler 210 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Cascade MC400 boiler 210 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Cascade MC400 boiler 210 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Cascade MC400 boiler 210 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Cascade MC400 boiler 210 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Cascade MC400 boiler 210 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Cascade MC400 boiler 210 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Cascade MC400 boiler 210 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Cascade MC400 boiler 210 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Cascade MC400 boiler 210 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Cascade MC400 boiler 210 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Cascade MC400 boiler 210 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Cascade MC400 boiler 210 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Cascade MC400 boiler 210 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Cascade MC400 boiler 210 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Cascade MC400 boiler 210 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Cascade MC400 boiler 210 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Cascade MC400 boiler 210 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Cascade MC400 boiler 210 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Cascade MC400 boiler 210 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Cascade MC400 boiler 210 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Cascade MC400 boiler 210 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Cascade MC400 boiler 210 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Cascade MC400 boiler 210 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Cascade MC400 boiler 210 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Cascade MC400 boiler 210 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Cascade MC400 boiler 210 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Cascade MC400 boiler 210 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Cascade MC400 boiler 210 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Cascade MC400 boiler 210 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Cascade MC400 boiler 210 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Cascade MC400 boiler 210 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Cascade MC400 boiler 210 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Cascade MC400 boiler 210 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Cascade MC400 boiler 210 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Cascade MC400 boiler 210 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Cascade MC400 boiler 210 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Cascade MC400 boiler 210 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Cascade MC400 boiler 210 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Cascade MC400 boiler 210 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Cascade MC400 boiler 210 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Cascade MC400 boiler 210 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Cascade MC400 boiler 210 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Cascade MC400 boiler 210 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Cascade MC400 boiler 210 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Cascade MC400 boiler 210 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Cascade MC400 boiler 210 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Cascade MC400 boiler 210 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Cascade MC400 boiler 210 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Cascade MC400 boiler 210 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Cascade MC400 boiler 210 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Cascade MC400 boiler 210 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Cascade MC400 boiler 210 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Cascade MC400 boiler 210 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Cascade MC400 boiler 210 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Cascade MC400 boiler 210 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Cascade MC400 boiler 210 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Cascade MC400 boiler 210 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Cascade MC400 boiler 210 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Cascade MC400 boiler 210 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Cascade MC400 boiler 210 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Cascade MC400 boiler 210 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Cascade MC400 boiler 210 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Cascade MC400 boiler 210 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Cascade MC400 boiler 210 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Cascade MC400 boiler 210 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Cascade MC400 boiler 210 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Cascade MC400 boiler 210 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Cascade MC400 boiler 210 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Cascade MC400 boiler 210 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Cascade MC400 boiler 210 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Cascade MC400 boiler 210 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Cascade MC400 boiler 210 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Cascade MC400 boiler 210 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Cascade MC400 boiler 210 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Cascade MC400 boiler 210 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Cascade MC400 boiler 210 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Cascade MC400 boiler 210 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Cascade MC400 boiler 210 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Cascade MC400 boiler 210 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Cascade MC400 boiler 210 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Cascade MC400 boiler 210 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Cascade MC400 boiler 210 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Cascade MC400 boiler 210 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Cascade MC400 boiler 210 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Cascade MC400 boiler 210 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Cascade MC400 boiler 210 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Cascade MC400 boiler 210 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Cascade MC400 boiler 210 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Cascade MC400 boiler 210 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Cascade MC400 boiler 210 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Cascade MC400 boiler 210 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
EasyControl Adapter boiler 211 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
EasyControl Adapter boiler 211 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
EasyControl Adapter boiler 211 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
EasyControl Adapter boiler 211 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
EasyControl Adapter boiler 211 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
EasyControl Adapter boiler 211 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
EasyControl Adapter boiler 211 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
EasyControl Adapter boiler 211 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
EasyControl Adapter boiler 211 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
EasyControl Adapter boiler 211 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
EasyControl Adapter boiler 211 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
EasyControl Adapter boiler 211 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
EasyControl Adapter boiler 211 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
EasyControl Adapter boiler 211 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
EasyControl Adapter boiler 211 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
EasyControl Adapter boiler 211 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
EasyControl Adapter boiler 211 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
EasyControl Adapter boiler 211 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
EasyControl Adapter boiler 211 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
EasyControl Adapter boiler 211 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
EasyControl Adapter boiler 211 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
EasyControl Adapter boiler 211 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
EasyControl Adapter boiler 211 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
EasyControl Adapter boiler 211 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
EasyControl Adapter boiler 211 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
EasyControl Adapter boiler 211 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
EasyControl Adapter boiler 211 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
EasyControl Adapter boiler 211 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
EasyControl Adapter boiler 211 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
EasyControl Adapter boiler 211 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
EasyControl Adapter boiler 211 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
EasyControl Adapter boiler 211 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
EasyControl Adapter boiler 211 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
EasyControl Adapter boiler 211 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
EasyControl Adapter boiler 211 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
EasyControl Adapter boiler 211 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
EasyControl Adapter boiler 211 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
EasyControl Adapter boiler 211 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
EasyControl Adapter boiler 211 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
EasyControl Adapter boiler 211 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
EasyControl Adapter boiler 211 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
EasyControl Adapter boiler 211 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
EasyControl Adapter boiler 211 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
EasyControl Adapter boiler 211 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
EasyControl Adapter boiler 211 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
EasyControl Adapter boiler 211 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
EasyControl Adapter boiler 211 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
EasyControl Adapter boiler 211 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
EasyControl Adapter boiler 211 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
EasyControl Adapter boiler 211 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
EasyControl Adapter boiler 211 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
EasyControl Adapter boiler 211 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
EasyControl Adapter boiler 211 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
EasyControl Adapter boiler 211 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
EasyControl Adapter boiler 211 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
EasyControl Adapter boiler 211 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
EasyControl Adapter boiler 211 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
EasyControl Adapter boiler 211 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
EasyControl Adapter boiler 211 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
EasyControl Adapter boiler 211 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
EasyControl Adapter boiler 211 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
EasyControl Adapter boiler 211 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
EasyControl Adapter boiler 211 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
EasyControl Adapter boiler 211 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
EasyControl Adapter boiler 211 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
EasyControl Adapter boiler 211 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
EasyControl Adapter boiler 211 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
EasyControl Adapter boiler 211 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
EasyControl Adapter boiler 211 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
EasyControl Adapter boiler 211 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
EasyControl Adapter boiler 211 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
EasyControl Adapter boiler 211 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
EasyControl Adapter boiler 211 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
EasyControl Adapter boiler 211 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
EasyControl Adapter boiler 211 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
EasyControl Adapter boiler 211 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
EasyControl Adapter boiler 211 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
EasyControl Adapter boiler 211 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
EasyControl Adapter boiler 211 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
EasyControl Adapter boiler 211 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
EasyControl Adapter boiler 211 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
EasyControl Adapter boiler 211 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
EasyControl Adapter boiler 211 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
EasyControl Adapter boiler 211 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
EasyControl Adapter boiler 211 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
EasyControl Adapter boiler 211 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
EasyControl Adapter boiler 211 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
EasyControl Adapter boiler 211 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
EasyControl Adapter boiler 211 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
EasyControl Adapter boiler 211 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
EasyControl Adapter boiler 211 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
EasyControl Adapter boiler 211 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
EasyControl Adapter boiler 211 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
EasyControl Adapter boiler 211 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
EasyControl Adapter boiler 211 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
EasyControl Adapter boiler 211 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
EasyControl Adapter boiler 211 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
EasyControl Adapter boiler 211 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
EasyControl Adapter boiler 211 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
EasyControl Adapter boiler 211 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
EasyControl Adapter boiler 211 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
EasyControl Adapter boiler 211 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
EasyControl Adapter boiler 211 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
EasyControl Adapter boiler 211 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
EasyControl Adapter boiler 211 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
EasyControl Adapter boiler 211 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
EasyControl Adapter boiler 211 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
EasyControl Adapter boiler 211 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
EasyControl Adapter boiler 211 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
EasyControl Adapter boiler 211 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
EasyControl Adapter boiler 211 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
EasyControl Adapter boiler 211 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
EasyControl Adapter boiler 211 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
EasyControl Adapter boiler 211 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
EasyControl Adapter boiler 211 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 netflowtemp heat network flow temp uint16 (>=0<=3199) C False sensor.boiler_heat_network_flow_temp sensor.boiler_netflowtemp 5 0 1/10 271 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatvalve heating valve uint8 (>=0<=100) % False sensor.boiler_heating_valve sensor.boiler_heatvalve 5 0 1 272 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.dhwvalve valve uint8 (>=0<=100) % False sensor.boiler_dhw_valve sensor.boiler_dhw_dhwvalve 5 9 1 74 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 keepwarmtemp keep warm temperature uint8 (>=0<=254) C True number.boiler_keep_warm_temperature number.boiler_keepwarmtemp 5 0 1 273 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 setreturntemp set temp return uint8 (>=0<=254) C True number.boiler_set_temp_return number.boiler_setreturntemp 5 0 1 274 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heating heating boolean False binary_sensor.boiler_heating binary_sensor.boiler_heating 5 0 1 275 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Greenstar HIU, Logamax kompakt WS170 boiler 219 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Greenstar HIU, Logamax kompakt WS170 boiler 219 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Greenstar HIU, Logamax kompakt WS170 boiler 219 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 reset reset cmd [-|maintenance|error|history|message] True sensor.boiler_reset sensor.boiler_reset 5 0 1 0 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatingoff force heating off boolean True switch.boiler_force_heating_off switch.boiler_heatingoff 5 0 1 1 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatingactive heating active boolean False binary_sensor.boiler_heating_active binary_sensor.boiler_heatingactive 5 0 1 2 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 tapwateractive tapwater active boolean False binary_sensor.boiler_tapwater_active binary_sensor.boiler_tapwateractive 5 0 1 3 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 selflowtemp selected flow temperature uint8 (>=0<=90) C True number.boiler_selected_flow_temperature number.boiler_selflowtemp 5 0 1 4 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.boiler_heating_pump_modulation sensor.boiler_heatingpumpmod 5 0 1 5 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.boiler_outside_temperature sensor.boiler_outdoortemp 5 0 1/10 6 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 curflowtemp current flow temperature uint16 (>=0<=3199) C False sensor.boiler_current_flow_temperature sensor.boiler_curflowtemp 5 0 1/10 7 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 rettemp return temperature uint16 (>=0<=3199) C False sensor.boiler_return_temperature sensor.boiler_rettemp 5 0 1/10 8 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 switchtemp mixing switch temperature uint16 (>=0<=3199) C False sensor.boiler_mixing_switch_temperature sensor.boiler_switchtemp 5 0 1/10 9 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 syspress system pressure uint8 (>=0<=25) bar False sensor.boiler_system_pressure sensor.boiler_syspress 5 0 1/10 10 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 boiltemp actual boiler temperature uint16 (>=0<=3199) C False sensor.boiler_actual_boiler_temperature sensor.boiler_boiltemp 5 0 1/10 11 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 headertemp low loss header uint16 (>=0<=3199) C False sensor.boiler_low_loss_header sensor.boiler_headertemp 5 0 1/10 12 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 exhausttemp exhaust temperature uint16 (>=0<=3199) C False sensor.boiler_exhaust_temperature sensor.boiler_exhausttemp 5 0 1/10 244 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burngas gas boolean False binary_sensor.boiler_gas binary_sensor.boiler_burngas 5 0 1 245 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burngas2 gas stage 2 boolean False binary_sensor.boiler_gas_stage_2 binary_sensor.boiler_burngas2 5 0 1 246 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 flamecurr flame current uint16 (>=0<=3199) µA False sensor.boiler_flame_current sensor.boiler_flamecurr 5 0 1/10 247 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 fanwork fan boolean False binary_sensor.boiler_fan binary_sensor.boiler_fanwork 5 0 1 248 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 ignwork ignition boolean False binary_sensor.boiler_ignition binary_sensor.boiler_ignwork 5 0 1 249 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 oilpreheat oil preheating boolean False binary_sensor.boiler_oil_preheating binary_sensor.boiler_oilpreheat 5 0 1 250 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burnminpower burner min power uint8 (>=0<=100) % True number.boiler_burner_min_power number.boiler_burnminpower 5 0 1 251 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burnmaxpower burner max power uint8 (>=0<=254) % True number.boiler_burner_max_power number.boiler_burnmaxpower 5 0 1 252 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burnminperiod burner min period uint8 (>=0<=120) minutes True number.boiler_burner_min_period number.boiler_burnminperiod 5 0 1 253 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 absburnpow burner current power (absolute) uint8 (>=0<=100) % False sensor.boiler_burner_current_power_(absolute) sensor.boiler_absburnpow 5 0 1 254 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatblock heating block uint16 (>=0<=3199) C False sensor.boiler_heating_block sensor.boiler_heatblock 5 0 1/10 255 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 boilhyston hysteresis on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_on_temperature number.boiler_boilhyston 5 0 1 256 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 boilhystoff hysteresis off temperature int8 (>=0<=20) C True number.boiler_hysteresis_off_temperature number.boiler_boilhystoff 5 0 1 257 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 boil2hyston hysteresis stage 2 on temperature int8 (>=-20<=0) C True number.boiler_hysteresis_stage_2_on_temperature number.boiler_boil2hyston 5 0 1 258 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 boil2hystoff hysteresis stage 2 off temperature int8 (>=0<=20) C True number.boiler_hysteresis_stage_2_off_temperature number.boiler_boil2hystoff 5 0 1 259 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 curveon heatingcurve on boolean True switch.boiler_heatingcurve_on switch.boiler_curveon 5 0 1 260 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 curvebase heatingcurve base uint8 (>=20<=90) C True number.boiler_heatingcurve_base number.boiler_curvebase 5 0 1 261 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 curveend heatingcurve end uint8 (>=20<=90) C True number.boiler_heatingcurve_end number.boiler_curveend 5 0 1 262 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 summertemp summer temperature uint8 (>=0<=45) C True number.boiler_summer_temperature number.boiler_summertemp 5 0 1 263 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 nofrostmode nofrost mode boolean True switch.boiler_nofrost_mode switch.boiler_nofrostmode 5 0 1 264 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 nofrosttemp nofrost temperature uint8 (>=0<=10) C True number.boiler_nofrost_temperature number.boiler_nofrosttemp 5 0 1 265 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatingactivated heating activated boolean True switch.boiler_heating_activated switch.boiler_heatingactivated 5 0 1 13 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatingtemp heating temperature uint8 (>=0<=90) C True number.boiler_heating_temperature number.boiler_heatingtemp 5 0 1 14 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatingpump heating pump boolean False binary_sensor.boiler_heating_pump binary_sensor.boiler_heatingpump 5 0 1 15 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pumpmodmax boiler pump max power uint8 (>=0<=100) % True number.boiler_boiler_pump_max_power number.boiler_pumpmodmax 5 0 1 16 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pumpmodmin boiler pump min power uint8 (>=0<=100) % True number.boiler_boiler_pump_min_power number.boiler_pumpmodmin 5 0 1 17 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pumpmode boiler pump mode enum [proportional|deltaP-1|deltaP-2|deltaP-3|deltaP-4] True select.boiler_boiler_pump_mode select.boiler_pumpmode 5 0 1 18 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pumpcharacter boiler pump characteristic enum [proportional|150mbar|200mbar|250mbar|300mbar|350mbar|400mbar] True select.boiler_boiler_pump_characteristic select.boiler_pumpcharacter 5 0 1 19 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pumpdelay pump delay uint8 (>=0<=60) minutes True number.boiler_pump_delay number.boiler_pumpdelay 5 0 1 20 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pumpontemp pump logic temperature uint8 (>=0<=60) C True number.boiler_pump_logic_temperature number.boiler_pumpontemp 5 0 1 21 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 selburnpow burner selected max power uint8 (>=0<=254) % True number.boiler_burner_selected_max_power number.boiler_selburnpow 5 0 1 22 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 curburnpow burner current power uint8 (>=0<=100) % False sensor.boiler_burner_current_power sensor.boiler_curburnpow 5 0 1 23 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burnstarts burner starts uint24 (>=0<=16777214) False sensor.boiler_burner_starts sensor.boiler_burnstarts 5 0 1 24 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burnworkmin total burner operating time time (>=0<=16777214) minutes False sensor.boiler_total_burner_operating_time sensor.boiler_burnworkmin 5 0 1 26 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 burn2workmin burner stage 2 operating time time (>=0<=16777214) minutes False sensor.boiler_burner_stage_2_operating_time sensor.boiler_burn2workmin 5 0 1 28 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatworkmin total heat operating time time (>=0<=16777214) minutes False sensor.boiler_total_heat_operating_time sensor.boiler_heatworkmin 5 0 1 30 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 heatstarts burner starts heating uint24 (>=0<=16777214) False sensor.boiler_burner_starts_heating sensor.boiler_heatstarts 5 0 1 32 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 ubauptime total UBA operating time time (>=0<=16777214) minutes False sensor.boiler_total_UBA_operating_time sensor.boiler_ubauptime 5 0 1 34 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 lastcode last error code string False sensor.boiler_last_error_code sensor.boiler_lastcode 5 0 1 36 28
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 servicecode service code string False sensor.boiler_service_code sensor.boiler_servicecode 5 0 1 64 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 servicecodenumber service code number uint16 (>=0<=31999) False sensor.boiler_service_code_number sensor.boiler_servicecodenumber 5 0 1 66 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 maintenancemessage maintenance message string False sensor.boiler_maintenance_message sensor.boiler_maintenancemessage 5 0 1 67 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 maintenance maintenance scheduled enum [off|time|date|manual] True select.boiler_maintenance_scheduled select.boiler_maintenance 5 0 1 69 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 maintenancetime time to next maintenance uint16 (>=0<=31999) hours True number.boiler_time_to_next_maintenance number.boiler_maintenancetime 5 0 1 70 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 maintenancedate next maintenance date string True sensor.boiler_next_maintenance_date sensor.boiler_maintenancedate 5 0 1 71 6
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 emergencyops emergency operation boolean True switch.boiler_emergency_operation switch.boiler_emergencyops 5 0 1 77 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 emergencytemp emergency temperature uint8 (>=15<=70) C True number.boiler_emergency_temperature number.boiler_emergencytemp 5 0 1 78 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pc0flow Flow PC0 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC0 sensor.boiler_pc0flow 5 0 1 79 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pc1flow Flow PC1 int16 (>=-31999<=31999) l/h False sensor.boiler_Flow_PC1 sensor.boiler_pc1flow 5 0 1 80 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pc1on PC1 boolean False binary_sensor.boiler_PC1 binary_sensor.boiler_pc1on 5 0 1 81 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 pc1rate PC1 rate uint8 (>=0<=100) % False sensor.boiler_PC1_rate sensor.boiler_pc1rate 5 0 1 82 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 meterheat meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_meter_heating sensor.boiler_meterheat 5 0 1/10 95 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.meter meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_meter sensor.boiler_dhw_meter 5 9 1/10 2 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 gasmeterheat gas meter heating uint24 (>=0<=1677721) kWh False sensor.boiler_gas_meter_heating sensor.boiler_gasmeterheat 5 0 1/10 266 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.gasmeter gas meter uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_gas_meter sensor.boiler_dhw_gasmeter 5 9 1/10 70 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 nrgheat2 energy heating 2 uint24 (>=0<=1677721) kWh False sensor.boiler_energy_heating_2 sensor.boiler_nrgheat2 5 0 1/10 268 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.nrg2 energy 2 uint24 (>=0<=1677721) kWh False sensor.boiler_dhw_energy_2 sensor.boiler_dhw_nrg2 5 9 1/10 72 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.tapactivated turn on/off boolean True switch.boiler_dhw_turn_on/off switch.boiler_dhw_tapactivated 5 9 1 28 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.settemp set temperature uint8 (>=0<=254) C False sensor.boiler_dhw_set_temperature sensor.boiler_dhw_settemp 5 9 1 29 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_temperature number.boiler_dhw_seltemp 5 9 1 30 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.seltemplow selected lower temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_lower_temperature number.boiler_dhw_seltemplow 5 9 1 31 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.tempecoplus selected eco+ temperature uint8 (>=0<=254) C True number.boiler_dhw_selected_eco+_temperature number.boiler_dhw_tempecoplus 5 9 1 32 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.seltempoff selected temperature for off uint8 (>=0<=254) C False sensor.boiler_dhw_selected_temperature_for_off sensor.boiler_dhw_seltempoff 5 9 1 33 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.seltempsingle single charge temperature uint8 (>=0<=254) C True number.boiler_dhw_single_charge_temperature number.boiler_dhw_seltempsingle 5 9 1 34 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.solartemp solar boiler temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_solar_boiler_temperature sensor.boiler_dhw_solartemp 5 9 1/10 35 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.type type enum [off|flow|buffered flow|buffer|layered buffer] False sensor.boiler_dhw_type sensor.boiler_dhw_type 5 9 1 36 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.comfort comfort enum [hot|eco|intelligent] True select.boiler_dhw_comfort select.boiler_dhw_comfort 5 9 1 37 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.comfort1 comfort mode enum [high comfort|eco] True select.boiler_dhw_comfort_mode select.boiler_dhw_comfort1 5 9 1 38 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.flowtempoffset flow temperature offset uint8 (>=0<=100) C True number.boiler_dhw_flow_temperature_offset number.boiler_dhw_flowtempoffset 5 9 1 39 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.chargeoptimization charge optimization boolean True switch.boiler_dhw_charge_optimization switch.boiler_dhw_chargeoptimization 5 9 1 40 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.maxpower max power uint8 (>=0<=254) % True number.boiler_dhw_max_power number.boiler_dhw_maxpower 5 9 1 41 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.maxtemp maximum temperature uint8 (>=0<=80) C True number.boiler_dhw_maximum_temperature number.boiler_dhw_maxtemp 5 9 1 42 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.circpump circulation pump available boolean True switch.boiler_dhw_circulation_pump_available switch.boiler_dhw_circpump 5 9 1 43 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.chargetype charging type enum [chargepump|3-way valve] False sensor.boiler_dhw_charging_type sensor.boiler_dhw_chargetype 5 9 1 44 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_on_temperature number.boiler_dhw_hyston 5 9 1 45 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.boiler_dhw_hysteresis_off_temperature number.boiler_dhw_hystoff 5 9 1 46 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.disinfectiontemp disinfection temperature uint8 (>=60<=80) C True number.boiler_dhw_disinfection_temperature number.boiler_dhw_disinfectiontemp 5 9 1 47 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.boiler_dhw_circulation_pump_mode select.boiler_dhw_circmode 5 9 1 48 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.circ circulation active boolean True switch.boiler_dhw_circulation_active switch.boiler_dhw_circ 5 9 1 49 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.curtemp current intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_intern_temperature sensor.boiler_dhw_curtemp 5 9 1/10 50 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_current_extern_temperature sensor.boiler_dhw_curtemp2 5 9 1/10 51 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.curflow current tap water flow uint8 (>=0<=25) l/min False sensor.boiler_dhw_current_tap_water_flow sensor.boiler_dhw_curflow 5 9 1/10 52 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_intern_temperature sensor.boiler_dhw_storagetemp1 5 9 1/10 53 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.storagetemp2 storage extern temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_storage_extern_temperature sensor.boiler_dhw_storagetemp2 5 9 1/10 54 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.activated activated boolean True switch.boiler_dhw_activated switch.boiler_dhw_activated 5 9 1 55 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.onetime one time charging boolean True switch.boiler_dhw_one_time_charging switch.boiler_dhw_onetime 5 9 1 56 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.disinfecting disinfecting boolean True switch.boiler_dhw_disinfecting switch.boiler_dhw_disinfecting 5 9 1 57 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.charging charging boolean False binary_sensor.boiler_dhw_charging binary_sensor.boiler_dhw_charging 5 9 1 58 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.recharging recharging boolean False binary_sensor.boiler_dhw_recharging binary_sensor.boiler_dhw_recharging 5 9 1 59 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.tempok temperature ok boolean False binary_sensor.boiler_dhw_temperature_ok binary_sensor.boiler_dhw_tempok 5 9 1 60 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.active active boolean False binary_sensor.boiler_dhw_active binary_sensor.boiler_dhw_active 5 9 1 61 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.3wayvalve 3-way valve active boolean False binary_sensor.boiler_dhw_3-way_valve_active binary_sensor.boiler_dhw_3wayvalve 5 9 1 62 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.chargepump charge pump boolean False binary_sensor.boiler_dhw_charge_pump binary_sensor.boiler_dhw_chargepump 5 9 1 63 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.mixertemp mixer temperature uint16 (>=0<=3199) C False sensor.boiler_dhw_mixer_temperature sensor.boiler_dhw_mixertemp 5 9 1/10 64 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.cylmiddletemp cylinder middle temperature (TS3) uint16 (>=0<=3199) C False sensor.boiler_dhw_cylinder_middle_temperature_(TS3) sensor.boiler_dhw_cylmiddletemp 5 9 1/10 65 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.starts starts uint24 (>=0<=16777214) False sensor.boiler_dhw_starts sensor.boiler_dhw_starts 5 9 1 66 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.workm active time time (>=0<=16777214) minutes False sensor.boiler_dhw_active_time sensor.boiler_dhw_workm 5 9 1 68 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 nompower nominal Power uint8 (>=0<=254) kW True number.boiler_nominal_Power number.boiler_nompower 5 0 1 270 1
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.boiler_total_energy sensor.boiler_nrgtotal 5 0 1/100 83 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 nrgheat energy heating uint24 (>=0<=10000000) kWh True number.boiler_energy_heating number.boiler_nrgheat 5 0 1/100 85 2
Logamax Plus GB122, Condense 2300, Junkers Cerapur GC2200W boiler 234 dhw.nrg energy uint24 (>=0<=10000000) kWh True number.boiler_dhw_energy number.boiler_dhw_nrg 5 9 1/100 0 2
Logamatic TC100, Moduline Easy thermostat 202 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Logamatic TC100, Moduline Easy thermostat 202 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Logamatic TC100, Moduline Easy thermostat 202 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
Logamatic TC100, Moduline Easy thermostat 202 hc1.seltemp selected room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp 6 1 1/100 0 1
Logamatic TC100, Moduline Easy thermostat 202 hc1.currtemp current room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/100 1 1
Logamatic TC100, Moduline Easy thermostat 202 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
EasyControl, CT200 thermostat 203 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
EasyControl, CT200 thermostat 203 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
EasyControl, CT200 thermostat 203 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
EasyControl, CT200 thermostat 203 hc1.seltemp selected room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp 6 1 1/100 0 1
EasyControl, CT200 thermostat 203 hc1.currtemp current room temperature int16 (>=-319<=319) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/100 1 1
EasyControl, CT200 thermostat 203 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
UI800, BC400 thermostat 4 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
UI800, BC400 thermostat 4 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
UI800, BC400 thermostat 4 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
UI800, BC400 thermostat 4 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
UI800, BC400 thermostat 4 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry 6 0 1 47 1
UI800, BC400 thermostat 4 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1/10 48 1
UI800, BC400 thermostat 4 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp 6 0 1 49 1
UI800, BC400 thermostat 4 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
UI800, BC400 thermostat 4 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
UI800, BC400 thermostat 4 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
UI800, BC400 thermostat 4 solar solar boolean True switch.thermostat_solar switch.thermostat_solar 6 0 1 53 1
UI800, BC400 thermostat 4 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
UI800, BC400 thermostat 4 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
UI800, BC400 thermostat 4 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
UI800, BC400 thermostat 4 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
UI800, BC400 thermostat 4 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
UI800, BC400 thermostat 4 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
UI800, BC400 thermostat 4 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
UI800, BC400 thermostat 4 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw 6 0 1 61 1
UI800, BC400 thermostat 4 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat 6 0 1 62 1
UI800, BC400 thermostat 4 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool 6 0 1 63 1
UI800, BC400 thermostat 4 absent absent boolean True switch.thermostat_absent switch.thermostat_absent 6 0 1 64 1
UI800, BC400 thermostat 4 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
UI800, BC400 thermostat 4 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
UI800, BC400 thermostat 4 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
UI800, BC400 thermostat 4 hc1.mode operating mode enum [off|manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
UI800, BC400 thermostat 4 hc1.modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
UI800, BC400 thermostat 4 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
UI800, BC400 thermostat 4 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
UI800, BC400 thermostat 4 hc1.comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp 6 1 1/2 7 1
UI800, BC400 thermostat 4 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
UI800, BC400 thermostat 4 hc1.designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
UI800, BC400 thermostat 4 hc1.offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1 10 1
UI800, BC400 thermostat 4 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
UI800, BC400 thermostat 4 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
UI800, BC400 thermostat 4 hc1.roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
UI800, BC400 thermostat 4 hc1.roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 1/10 14 1
UI800, BC400 thermostat 4 hc1.curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl 6 1 1/10 15 1
UI800, BC400 thermostat 4 hc1.nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
UI800, BC400 thermostat 4 hc1.nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
UI800, BC400 thermostat 4 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
UI800, BC400 thermostat 4 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
UI800, BC400 thermostat 4 hc1.summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode 6 1 1 20 1
UI800, BC400 thermostat 4 hc1.hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode 6 1 1 21 1
UI800, BC400 thermostat 4 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
UI800, BC400 thermostat 4 hc1.hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate 6 1 1 23 1
UI800, BC400 thermostat 4 hc1.vacationmode vacation mode boolean False binary_sensor.thermostat_hc1_vacation_mode binary_sensor.thermostat_hc1_vacationmode 6 1 1 24 1
UI800, BC400 thermostat 4 hc1.controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
UI800, BC400 thermostat 4 hc1.program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
UI800, BC400 thermostat 4 hc1.tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
UI800, BC400 thermostat 4 hc1.cooltemp cooling temperature int8 (>=-1<=30) C True number.thermostat_hc1_cooling_temperature number.thermostat_hc1_cooltemp 6 1 1/2 28 1
UI800, BC400 thermostat 4 hc1.fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup 6 1 1 29 1
UI800, BC400 thermostat 4 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
UI800, BC400 thermostat 4 hc1.reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
UI800, BC400 thermostat 4 hc1.noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
UI800, BC400 thermostat 4 hc1.reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
UI800, BC400 thermostat 4 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
UI800, BC400 thermostat 4 hc1.hpcooling hp cooling boolean True switch.thermostat_hc1_hp_cooling switch.thermostat_hc1_hpcooling 6 1 1 35 1
UI800, BC400 thermostat 4 hc1.coolingon cooling on boolean False binary_sensor.thermostat_hc1_cooling_on binary_sensor.thermostat_hc1_coolingon 6 1 1 36 1
UI800, BC400 thermostat 4 hc1.hpmode HP Mode enum [heating|cooling|heating & cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode 6 1 1 37 1
UI800, BC400 thermostat 4 hc1.dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset 6 1 1 38 1
UI800, BC400 thermostat 4 hc1.roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff 6 1 1 39 1
UI800, BC400 thermostat 4 hc1.hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp 6 1 1 40 1
UI800, BC400 thermostat 4 hc1.control control device enum [off|-|RC100|RC100H|-|RC120RF|RC220/RT800|single] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
UI800, BC400 thermostat 4 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
UI800, BC400 thermostat 4 hc1.remotehum room humidity from remote cmd [] (>=-1<=101) % True sensor.thermostat_hc1_room_humidity_from_remote sensor.thermostat_hc1_remotehum 6 1 1 43 1
UI800, BC400 thermostat 4 hc1.heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay 6 1 1 44 1
UI800, BC400 thermostat 4 hc1.heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay 6 1 1 45 1
UI800, BC400 thermostat 4 hc1.instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart 6 1 1 46 1
UI800, BC400 thermostat 4 hc1.boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost 6 1 1 47 1
UI800, BC400 thermostat 4 hc1.boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime 6 1 1 48 1
UI800, BC400 thermostat 4 hc1.coolstart cooling starttemp uint8 (>=20<=35) C True number.thermostat_hc1_cooling_starttemp number.thermostat_hc1_coolstart 6 1 1 49 1
UI800, BC400 thermostat 4 hc1.coolondelay cooling on delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_on_delay number.thermostat_hc1_coolondelay 6 1 1 50 1
UI800, BC400 thermostat 4 hc1.cooloffdelay cooling off delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_off_delay number.thermostat_hc1_cooloffdelay 6 1 1 51 1
UI800, BC400 thermostat 4 hc1.switchprogmode switch program mode enum [level|absolute] True select.thermostat_hc1_switch_program_mode select.thermostat_hc1_switchprogmode 6 1 1 52 1
UI800, BC400 thermostat 4 hc1.redthreshold reduction threshold int8 (>=12<=22) C True number.thermostat_hc1_reduction_threshold number.thermostat_hc1_redthreshold 6 1 1/2 53 1
UI800, BC400 thermostat 4 hc1.solarinfl solar influence uint8 (>=-5<=4294967295) C True number.thermostat_hc1_solar_influence number.thermostat_hc1_solarinfl 6 1 1 54 1
UI800, BC400 thermostat 4 hc1.currsolarinfl curent solar influence uint8 (>=0<=25) C False sensor.thermostat_hc1_curent_solar_influence sensor.thermostat_hc1_currsolarinfl 6 1 1/10 55 1
UI800, BC400 thermostat 4 dhw.mode operating mode enum [off|eco+|eco|comfort|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
UI800, BC400 thermostat 4 dhw.modetype mode type enum [off|eco|comfort|eco+] False sensor.thermostat_dhw_mode_type sensor.thermostat_dhw_modetype 6 9 1 1 1
UI800, BC400 thermostat 4 dhw.settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp 6 9 1 2 1
UI800, BC400 thermostat 4 dhw.settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow 6 9 1 3 1
UI800, BC400 thermostat 4 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
UI800, BC400 thermostat 4 dhw.chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration 6 9 15 5 1
UI800, BC400 thermostat 4 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
UI800, BC400 thermostat 4 dhw.extra extra boolean False binary_sensor.thermostat_dhw_extra binary_sensor.thermostat_dhw_extra 6 9 1 7 1
UI800, BC400 thermostat 4 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
UI800, BC400 thermostat 4 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
UI800, BC400 thermostat 4 dhw.disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime 6 9 15 10 1
UI800, BC400 thermostat 4 dhw.dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating 6 9 1 11 1
UI800, BC400 thermostat 4 dhw.dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime 6 9 15 12 1
CR11 thermostat 10 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
CR11 thermostat 10 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
CR11 thermostat 10 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
CR11 thermostat 10 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
CR11 thermostat 10 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
CR11 thermostat 10 hc1.mode operating mode enum [off|manual] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
CR11 thermostat 10 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
CR11 thermostat 10 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC10 thermostat 65 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC10 thermostat 65 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC10 thermostat 65 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC10 thermostat 65 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC10 thermostat 65 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC10 thermostat 65 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC10 thermostat 65 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC10 thermostat 65 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC10 thermostat 65 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC10 thermostat 65 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
RC10 thermostat 65 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC10 thermostat 65 hc1.program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC10 thermostat 65 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC10 thermostat 65 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC10 thermostat 65 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC10 thermostat 65 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC10 thermostat 65 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC10 thermostat 65 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC30 thermostat 67 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC30 thermostat 67 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC30 thermostat 67 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC30 thermostat 67 display display enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
RC30 thermostat 67 language language enum [german|dutch|french|italian] False sensor.thermostat_language sensor.thermostat_language 6 0 1 66 1
RC30 thermostat 67 clockoffset clock offset int8 (>=-126<=126) seconds True number.thermostat_clock_offset number.thermostat_clockoffset 6 0 1 67 1
RC30 thermostat 67 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
RC30 thermostat 67 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC30 thermostat 67 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1 6 0 1/10 68 1
RC30 thermostat 67 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2 6 0 1/10 69 1
RC30 thermostat 67 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
RC30 thermostat 67 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1 48 1
RC30 thermostat 67 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
RC30 thermostat 67 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC30 thermostat 67 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC30 thermostat 67 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC30 thermostat 67 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC30 thermostat 67 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC30 thermostat 67 hc1.daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
RC30 thermostat 67 hc1.nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC30 thermostat 67 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
RC30 thermostat 67 hc1.offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1/2 10 1
RC30 thermostat 67 hc1.holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp 6 1 1/2 58 1
RC30 thermostat 67 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
RC30 thermostat 67 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC30 thermostat 67 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC30 thermostat 67 hc1.holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode 6 1 1 59 1
RC30 thermostat 67 hc1.nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
RC30 thermostat 67 hc1.nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
RC30 thermostat 67 hc1.roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
RC30 thermostat 67 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC30 thermostat 67 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC30 thermostat 67 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset 6 1 1 60 1
RC30 thermostat 67 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC30 thermostat 67 hc1.reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
RC30 thermostat 67 hc1.controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
RC30 thermostat 67 hc1.control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
RC30 thermostat 67 hc1.holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays 6 1 1 61 13
RC30 thermostat 67 hc1.vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations 6 1 1 74 13
RC30 thermostat 67 hc1.program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC30 thermostat 67 hc1.pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause 6 1 1 87 1
RC30 thermostat 67 hc1.party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party 6 1 1 88 1
RC30 thermostat 67 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC30 thermostat 67 hc1.noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
RC30 thermostat 67 hc1.reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
RC30 thermostat 67 hc1.vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp 6 1 1 89 1
RC30 thermostat 67 hc1.vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode 6 1 1 90 1
RC30 thermostat 67 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
RC30 thermostat 67 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
RC30 thermostat 67 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
RC30 thermostat 67 hc1.switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1 6 1 1 91 8
RC30 thermostat 67 hc1.switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2 6 1 1 99 8
RC30 thermostat 67 dhw.mode operating mode enum [off|on|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
RC30 thermostat 67 dhw.circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
RC30 thermostat 67 dhw.progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode 6 9 1 13 1
RC30 thermostat 67 dhw.circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog 6 9 1 14 1
RC30 thermostat 67 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
RC30 thermostat 67 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
RC30 thermostat 67 dhw.disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour 6 9 1 15 1
RC30 thermostat 67 dhw.maxtemp maximum temperature uint8 (>=0<=254) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp 6 9 1 16 1
RC30 thermostat 67 dhw.onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey 6 9 1 17 1
RC30 thermostat 67 dhw.switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime 6 9 1 18 8
RC30 thermostat 67 dhw.circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime 6 9 1 26 8
RC30 thermostat 67 dhw.holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays 6 9 1 34 13
RC30 thermostat 67 dhw.vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations 6 9 1 47 13
RC20, Moduline 300 thermostat 77 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC20, Moduline 300 thermostat 77 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC20, Moduline 300 thermostat 77 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC20, Moduline 300 thermostat 77 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC20, Moduline 300 thermostat 77 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC20, Moduline 300 thermostat 77 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC20, Moduline 300 thermostat 77 hc1.mode operating mode enum [off|manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC20, Moduline 300 thermostat 77 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
RC20, Moduline 300 thermostat 77 hc1.offtemp temperature when mode is off uint8 (>=0<=127) C True number.thermostat_hc1_temperature_when_mode_is_off number.thermostat_hc1_offtemp 6 1 1/2 107 1
RC20, Moduline 300 thermostat 77 hc1.daytemp2 day temperature T2 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T2 number.thermostat_hc1_daytemp2 6 1 1/2 108 1
RC20, Moduline 300 thermostat 77 hc1.daytemp3 day temperature T3 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T3 number.thermostat_hc1_daytemp3 6 1 1/2 109 1
RC20, Moduline 300 thermostat 77 hc1.daytemp4 day temperature T4 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T4 number.thermostat_hc1_daytemp4 6 1 1/2 110 1
RC20, Moduline 300 thermostat 77 hc1.nighttemp night temperature T1 uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature_T1 number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC20, Moduline 300 thermostat 77 hc1.switchtime program switchtime string True sensor.thermostat_hc1_program_switchtime sensor.thermostat_hc1_switchtime 6 1 1 111 8
Moduline 400 thermostat 78 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Moduline 400 thermostat 78 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Moduline 400 thermostat 78 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
Moduline 400 thermostat 78 clockoffset clock offset int8 (>=-126<=126) seconds True number.thermostat_clock_offset number.thermostat_clockoffset 6 0 1 67 1
Moduline 400 thermostat 78 autodst automatic change daylight saving time boolean True switch.thermostat_automatic_change_daylight_saving_time switch.thermostat_autodst 6 0 1 70 1
Moduline 400 thermostat 78 language language enum [german|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
Moduline 400 thermostat 78 backlight key backlight boolean True switch.thermostat_key_backlight switch.thermostat_backlight 6 0 1 71 1
Moduline 400 thermostat 78 brightness screen brightness int8 (>=-15<=15) True number.thermostat_screen_brightness number.thermostat_brightness 6 0 1 72 1
Moduline 400 thermostat 78 mixingvalves mixing valves uint8 (>=0<=2) True number.thermostat_mixing_valves number.thermostat_mixingvalves 6 0 1 73 1
Moduline 400 thermostat 78 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
Moduline 400 thermostat 78 heatingpid heating PID enum [fast|medium|slow] True select.thermostat_heating_PID select.thermostat_heatingpid 6 0 1 74 1
Moduline 400 thermostat 78 preheating preheating in the clock program boolean True switch.thermostat_preheating_in_the_clock_program switch.thermostat_preheating 6 0 1 75 1
Moduline 400 thermostat 78 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
Moduline 400 thermostat 78 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
Moduline 400 thermostat 78 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
Moduline 400 thermostat 78 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
Moduline 400 thermostat 78 hc1.mode operating mode enum [off|manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
Moduline 400 thermostat 78 hc1.pause pause time uint8 (>=0<=254) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause 6 1 1 87 1
Moduline 400 thermostat 78 hc1.party party time uint8 (>=0<=254) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party 6 1 1 88 1
Moduline 400 thermostat 78 hc1.vacations1 vacation dates 1 string True sensor.thermostat_hc1_vacation_dates_1 sensor.thermostat_hc1_vacations1 6 1 1 119 11
Moduline 400 thermostat 78 hc1.vacations2 vacation dates 2 string True sensor.thermostat_hc1_vacation_dates_2 sensor.thermostat_hc1_vacations2 6 1 1 130 11
Moduline 400 thermostat 78 hc1.vacations3 vacation dates 3 string True sensor.thermostat_hc1_vacation_dates_3 sensor.thermostat_hc1_vacations3 6 1 1 141 11
Moduline 400 thermostat 78 hc1.vacations4 vacation dates 4 string True sensor.thermostat_hc1_vacation_dates_4 sensor.thermostat_hc1_vacations4 6 1 1 152 11
Moduline 400 thermostat 78 hc1.vacations5 vacation dates 5 string True sensor.thermostat_hc1_vacation_dates_5 sensor.thermostat_hc1_vacations5 6 1 1 163 11
Moduline 400 thermostat 78 hc1.vacations6 vacation dates 6 string True sensor.thermostat_hc1_vacation_dates_6 sensor.thermostat_hc1_vacations6 6 1 1 174 11
Moduline 400 thermostat 78 hc1.vacations7 vacation dates 7 string True sensor.thermostat_hc1_vacation_dates_7 sensor.thermostat_hc1_vacations7 6 1 1 185 11
Moduline 400 thermostat 78 hc1.program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
Moduline 400 thermostat 78 hc1.switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1 6 1 1 91 8
Moduline 400 thermostat 78 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
Moduline 400 thermostat 78 hc1.controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
Moduline 400 thermostat 78 hc1.holidaytemp holiday temperature uint8 (>=0<=127) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp 6 1 1/2 58 1
Moduline 400 thermostat 78 hc1.nighttemp night temperature T1 uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature_T1 number.thermostat_hc1_nighttemp 6 1 1/2 57 1
Moduline 400 thermostat 78 hc1.daytemp2 day temperature T2 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T2 number.thermostat_hc1_daytemp2 6 1 1/2 108 1
Moduline 400 thermostat 78 hc1.daytemp3 day temperature T3 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T3 number.thermostat_hc1_daytemp3 6 1 1/2 109 1
Moduline 400 thermostat 78 hc1.daytemp4 day temperature T4 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T4 number.thermostat_hc1_daytemp4 6 1 1/2 110 1
Moduline 400 thermostat 78 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
Moduline 400 thermostat 78 hc1.offtemp temperature when mode is off uint8 (>=0<=127) C True number.thermostat_hc1_temperature_when_mode_is_off number.thermostat_hc1_offtemp 6 1 1/2 107 1
Moduline 400 thermostat 78 dhw.mode operating mode enum [on|off|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
Moduline 400 thermostat 78 dhw.whenmodeoff when thermostat mode off boolean True switch.thermostat_dhw_when_thermostat_mode_off switch.thermostat_dhw_whenmodeoff 6 9 1 60 1
Moduline 400 thermostat 78 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
Moduline 400 thermostat 78 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
Moduline 400 thermostat 78 dhw.disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour 6 9 1 15 1
RC10, Moduline 100 thermostat 79 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC10, Moduline 100 thermostat 79 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC10, Moduline 100 thermostat 79 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
RC10, Moduline 100 thermostat 79 heatingpid heating PID enum [fast|medium|slow] True select.thermostat_heating_PID select.thermostat_heatingpid 6 0 1 74 1
RC10, Moduline 100 thermostat 79 backlight key backlight boolean True switch.thermostat_key_backlight switch.thermostat_backlight 6 0 1 71 1
RC10, Moduline 100 thermostat 79 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC10, Moduline 100 thermostat 79 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC10, Moduline 100 thermostat 79 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC10, Moduline 100 thermostat 79 hc1.mode operating mode enum [nofrost|night|day] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC10, Moduline 100 thermostat 79 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
RC10, Moduline 100 thermostat 79 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC10, Moduline 100 thermostat 79 hc1.reducehours duration for nighttemp uint8 (>=0<=254) hours True number.thermostat_hc1_duration_for_nighttemp number.thermostat_hc1_reducehours 6 1 1 196 1
RC10, Moduline 100 thermostat 79 hc1.reduceminutes remaining time for nightmode uint16 (>=0<=31999) minutes False sensor.thermostat_hc1_remaining_time_for_nightmode sensor.thermostat_hc1_reduceminutes 6 1 1 197 1
RC10, Moduline 100 thermostat 79 dhw.mode operating mode enum [on|off|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
Moduline 200 thermostat 80 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Moduline 200 thermostat 80 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Moduline 200 thermostat 80 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
Moduline 200 thermostat 80 heatingpid heating PID enum [fast|medium|slow] True select.thermostat_heating_PID select.thermostat_heatingpid 6 0 1 74 1
Moduline 200 thermostat 80 backlight key backlight boolean True switch.thermostat_key_backlight switch.thermostat_backlight 6 0 1 71 1
Moduline 200 thermostat 80 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
Moduline 200 thermostat 80 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
Moduline 200 thermostat 80 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
Moduline 200 thermostat 80 hc1.mode operating mode enum [nofrost|night|day] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
Moduline 200 thermostat 80 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
Moduline 200 thermostat 80 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
Moduline 200 thermostat 80 hc1.reducehours duration for nighttemp uint8 (>=0<=254) hours True number.thermostat_hc1_duration_for_nighttemp number.thermostat_hc1_reducehours 6 1 1 196 1
Moduline 200 thermostat 80 hc1.reduceminutes remaining time for nightmode uint16 (>=0<=31999) minutes False sensor.thermostat_hc1_remaining_time_for_nightmode sensor.thermostat_hc1_reduceminutes 6 1 1 197 1
Moduline 200 thermostat 80 dhw.mode operating mode enum [on|off|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
RC35 thermostat 86 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC35 thermostat 86 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC35 thermostat 86 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC35 thermostat 86 intoffset internal temperature offset int8 (>=-5<=5) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
RC35 thermostat 86 minexttemp minimal external temperature int8 (>=-30<=0) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC35 thermostat 86 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1 6 0 1/10 68 1
RC35 thermostat 86 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2 6 0 1/10 69 1
RC35 thermostat 86 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
RC35 thermostat 86 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1 48 1
RC35 thermostat 86 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
RC35 thermostat 86 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC35 thermostat 86 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC35 thermostat 86 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC35 thermostat 86 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC35 thermostat 86 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC35 thermostat 86 hc1.daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
RC35 thermostat 86 hc1.nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC35 thermostat 86 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
RC35 thermostat 86 hc1.offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1/2 10 1
RC35 thermostat 86 hc1.holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp 6 1 1/2 58 1
RC35 thermostat 86 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
RC35 thermostat 86 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC35 thermostat 86 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC35 thermostat 86 hc1.holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode 6 1 1 59 1
RC35 thermostat 86 hc1.nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
RC35 thermostat 86 hc1.nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
RC35 thermostat 86 hc1.roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
RC35 thermostat 86 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC35 thermostat 86 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC35 thermostat 86 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset 6 1 1 60 1
RC35 thermostat 86 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC35 thermostat 86 hc1.reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
RC35 thermostat 86 hc1.controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
RC35 thermostat 86 hc1.control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
RC35 thermostat 86 hc1.holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays 6 1 1 61 13
RC35 thermostat 86 hc1.vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations 6 1 1 74 13
RC35 thermostat 86 hc1.program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC35 thermostat 86 hc1.pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause 6 1 1 87 1
RC35 thermostat 86 hc1.party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party 6 1 1 88 1
RC35 thermostat 86 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC35 thermostat 86 hc1.noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
RC35 thermostat 86 hc1.reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
RC35 thermostat 86 hc1.vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp 6 1 1 89 1
RC35 thermostat 86 hc1.vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode 6 1 1 90 1
RC35 thermostat 86 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
RC35 thermostat 86 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
RC35 thermostat 86 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
RC35 thermostat 86 hc1.switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1 6 1 1 91 8
RC35 thermostat 86 hc1.switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2 6 1 1 99 8
RC35 thermostat 86 dhw.mode operating mode enum [off|on|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
RC35 thermostat 86 dhw.circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
RC35 thermostat 86 dhw.progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode 6 9 1 13 1
RC35 thermostat 86 dhw.circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog 6 9 1 14 1
RC35 thermostat 86 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
RC35 thermostat 86 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
RC35 thermostat 86 dhw.disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour 6 9 1 15 1
RC35 thermostat 86 dhw.maxtemp maximum temperature uint8 (>=60<=80) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp 6 9 1 16 1
RC35 thermostat 86 dhw.onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey 6 9 1 17 1
RC35 thermostat 86 dhw.switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime 6 9 1 18 8
RC35 thermostat 86 dhw.circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime 6 9 1 26 8
RC35 thermostat 86 dhw.holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays 6 9 1 34 13
RC35 thermostat 86 dhw.vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations 6 9 1 47 13
RC10, Moduline 100 thermostat 90 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC10, Moduline 100 thermostat 90 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC10, Moduline 100 thermostat 90 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC10, Moduline 100 thermostat 90 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC10, Moduline 100 thermostat 90 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC10, Moduline 100 thermostat 90 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC10, Moduline 100 thermostat 90 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC10, Moduline 100 thermostat 90 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC10, Moduline 100 thermostat 90 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC10, Moduline 100 thermostat 90 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
RC10, Moduline 100 thermostat 90 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC10, Moduline 100 thermostat 90 hc1.program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC10, Moduline 100 thermostat 90 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC10, Moduline 100 thermostat 90 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC10, Moduline 100 thermostat 90 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC10, Moduline 100 thermostat 90 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC10, Moduline 100 thermostat 90 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC10, Moduline 100 thermostat 90 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC20RF thermostat 93 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC20RF thermostat 93 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC20RF thermostat 93 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC20RF thermostat 93 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC20RF thermostat 93 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC20RF thermostat 93 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC20RF thermostat 93 hc1.mode operating mode enum [off|manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC20RF thermostat 93 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
RC20RF thermostat 93 hc1.offtemp temperature when mode is off uint8 (>=0<=127) C True number.thermostat_hc1_temperature_when_mode_is_off number.thermostat_hc1_offtemp 6 1 1/2 107 1
RC20RF thermostat 93 hc1.daytemp2 day temperature T2 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T2 number.thermostat_hc1_daytemp2 6 1 1/2 108 1
RC20RF thermostat 93 hc1.daytemp3 day temperature T3 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T3 number.thermostat_hc1_daytemp3 6 1 1/2 109 1
RC20RF thermostat 93 hc1.daytemp4 day temperature T4 uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature_T4 number.thermostat_hc1_daytemp4 6 1 1/2 110 1
RC20RF thermostat 93 hc1.nighttemp night temperature T1 uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature_T1 number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC20RF thermostat 93 hc1.switchtime program switchtime string True sensor.thermostat_hc1_program_switchtime sensor.thermostat_hc1_switchtime 6 1 1 111 8
RFM20 Remote thermostat 94 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RFM20 Remote thermostat 94 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RFM20 Remote thermostat 94 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RFM20 Remote thermostat 94 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RFM20 Remote thermostat 94 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RFM20 Remote thermostat 94 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC25 thermostat 151 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC25 thermostat 151 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC25 thermostat 151 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC25 thermostat 151 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC25 thermostat 151 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC25 thermostat 151 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC25 thermostat 151 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC25 thermostat 151 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC25 thermostat 151 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC25 thermostat 151 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
RC25 thermostat 151 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
RC25 thermostat 151 hc1.program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC25 thermostat 151 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC25 thermostat 151 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC25 thermostat 151 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC25 thermostat 151 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC25 thermostat 151 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC25 thermostat 151 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC200, CW100, CR120, CR50 thermostat 157 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC200, CW100, CR120, CR50 thermostat 157 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC200, CW100, CR120, CR50 thermostat 157 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC200, CW100, CR120, CR50 thermostat 157 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
RC200, CW100, CR120, CR50 thermostat 157 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry 6 0 1 47 1
RC200, CW100, CR120, CR50 thermostat 157 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1/10 48 1
RC200, CW100, CR120, CR50 thermostat 157 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp 6 0 1 49 1
RC200, CW100, CR120, CR50 thermostat 157 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
RC200, CW100, CR120, CR50 thermostat 157 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC200, CW100, CR120, CR50 thermostat 157 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
RC200, CW100, CR120, CR50 thermostat 157 solar solar boolean True switch.thermostat_solar switch.thermostat_solar 6 0 1 53 1
RC200, CW100, CR120, CR50 thermostat 157 vacations vacation dates string True sensor.thermostat_vacation_dates sensor.thermostat_vacations 6 0 1 76 13
RC200, CW100, CR120, CR50 thermostat 157 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
RC200, CW100, CR120, CR50 thermostat 157 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
RC200, CW100, CR120, CR50 thermostat 157 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
RC200, CW100, CR120, CR50 thermostat 157 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
RC200, CW100, CR120, CR50 thermostat 157 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
RC200, CW100, CR120, CR50 thermostat 157 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
RC200, CW100, CR120, CR50 thermostat 157 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
RC200, CW100, CR120, CR50 thermostat 157 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw 6 0 1 61 1
RC200, CW100, CR120, CR50 thermostat 157 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat 6 0 1 62 1
RC200, CW100, CR120, CR50 thermostat 157 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool 6 0 1 63 1
RC200, CW100, CR120, CR50 thermostat 157 absent absent boolean True switch.thermostat_absent switch.thermostat_absent 6 0 1 64 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.mode operating mode enum [manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp 6 1 1/2 7 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1 10 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 1/10 14 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl 6 1 1/10 15 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode 6 1 1 20 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode 6 1 1 21 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate 6 1 1 23 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.vacationmode vacation mode boolean False binary_sensor.thermostat_hc1_vacation_mode binary_sensor.thermostat_hc1_vacationmode 6 1 1 24 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.controlmode control mode enum [optimized|simple|n/a|room|power] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.cooltemp cooling temperature int8 (>=-1<=30) C True number.thermostat_hc1_cooling_temperature number.thermostat_hc1_cooltemp 6 1 1/2 28 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup 6 1 1 29 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.hpcooling hp cooling boolean True switch.thermostat_hc1_hp_cooling switch.thermostat_hc1_hpcooling 6 1 1 35 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.coolingon cooling on boolean False binary_sensor.thermostat_hc1_cooling_on binary_sensor.thermostat_hc1_coolingon 6 1 1 36 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.hpmode HP Mode enum [heating|cooling|heating & cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode 6 1 1 37 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset 6 1 1 38 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff 6 1 1 39 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp 6 1 1 40 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay 6 1 1 44 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay 6 1 1 45 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart 6 1 1 46 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost 6 1 1 47 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime 6 1 1 48 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.coolstart cooling starttemp uint8 (>=20<=35) C True number.thermostat_hc1_cooling_starttemp number.thermostat_hc1_coolstart 6 1 1 49 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.coolondelay cooling on delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_on_delay number.thermostat_hc1_coolondelay 6 1 1 50 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.cooloffdelay cooling off delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_off_delay number.thermostat_hc1_cooloffdelay 6 1 1 51 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.switchprogmode switch program mode enum [level|absolute] True select.thermostat_hc1_switch_program_mode select.thermostat_hc1_switchprogmode 6 1 1 52 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.redthreshold reduction threshold int8 (>=12<=22) C True number.thermostat_hc1_reduction_threshold number.thermostat_hc1_redthreshold 6 1 1/2 53 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.solarinfl solar influence uint8 (>=-5<=4294967295) C True number.thermostat_hc1_solar_influence number.thermostat_hc1_solarinfl 6 1 1 54 1
RC200, CW100, CR120, CR50 thermostat 157 hc1.currsolarinfl curent solar influence uint8 (>=0<=25) C False sensor.thermostat_hc1_curent_solar_influence sensor.thermostat_hc1_currsolarinfl 6 1 1/10 55 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.mode operating mode enum [off|on|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.modetype mode type enum [off|eco|comfort|eco+] False sensor.thermostat_dhw_mode_type sensor.thermostat_dhw_modetype 6 9 1 1 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp 6 9 1 2 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow 6 9 1 3 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration 6 9 15 5 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.extra extra boolean False binary_sensor.thermostat_dhw_extra binary_sensor.thermostat_dhw_extra 6 9 1 7 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime 6 9 15 10 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating 6 9 1 11 1
RC200, CW100, CR120, CR50 thermostat 157 dhw.dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime 6 9 15 12 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry 6 0 1 47 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1/10 48 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp 6 0 1 49 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 solar solar boolean True switch.thermostat_solar switch.thermostat_solar 6 0 1 53 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw 6 0 1 61 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat 6 0 1 62 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool 6 0 1 63 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 absent absent boolean True switch.thermostat_absent switch.thermostat_absent 6 0 1 64 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.mode operating mode enum [manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp 6 1 1/2 7 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1 10 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 1/10 14 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl 6 1 1/10 15 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode 6 1 1 20 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode 6 1 1 21 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate 6 1 1 23 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.vacationmode vacation mode boolean False binary_sensor.thermostat_hc1_vacation_mode binary_sensor.thermostat_hc1_vacationmode 6 1 1 24 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.cooltemp cooling temperature int8 (>=-1<=30) C True number.thermostat_hc1_cooling_temperature number.thermostat_hc1_cooltemp 6 1 1/2 28 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup 6 1 1 29 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.hpcooling hp cooling boolean True switch.thermostat_hc1_hp_cooling switch.thermostat_hc1_hpcooling 6 1 1 35 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.coolingon cooling on boolean False binary_sensor.thermostat_hc1_cooling_on binary_sensor.thermostat_hc1_coolingon 6 1 1 36 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.hpmode HP Mode enum [heating|cooling|heating & cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode 6 1 1 37 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset 6 1 1 38 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff 6 1 1 39 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp 6 1 1 40 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.remotehum room humidity from remote cmd [] (>=-1<=101) % True sensor.thermostat_hc1_room_humidity_from_remote sensor.thermostat_hc1_remotehum 6 1 1 43 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay 6 1 1 44 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay 6 1 1 45 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart 6 1 1 46 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost 6 1 1 47 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime 6 1 1 48 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.coolstart cooling starttemp uint8 (>=20<=35) C True number.thermostat_hc1_cooling_starttemp number.thermostat_hc1_coolstart 6 1 1 49 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.coolondelay cooling on delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_on_delay number.thermostat_hc1_coolondelay 6 1 1 50 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.cooloffdelay cooling off delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_off_delay number.thermostat_hc1_cooloffdelay 6 1 1 51 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.switchprogmode switch program mode enum [level|absolute] True select.thermostat_hc1_switch_program_mode select.thermostat_hc1_switchprogmode 6 1 1 52 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.redthreshold reduction threshold int8 (>=12<=22) C True number.thermostat_hc1_reduction_threshold number.thermostat_hc1_redthreshold 6 1 1/2 53 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.solarinfl solar influence uint8 (>=-5<=4294967295) C True number.thermostat_hc1_solar_influence number.thermostat_hc1_solarinfl 6 1 1 54 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 hc1.currsolarinfl curent solar influence uint8 (>=0<=25) C False sensor.thermostat_hc1_curent_solar_influence sensor.thermostat_hc1_currsolarinfl 6 1 1/10 55 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.mode operating mode enum [off|normal|comfort|auto|own prog] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.modetype mode type enum [off|eco|comfort|eco+] False sensor.thermostat_dhw_mode_type sensor.thermostat_dhw_modetype 6 9 1 1 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp 6 9 1 2 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow 6 9 1 3 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration 6 9 15 5 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.extra extra boolean False binary_sensor.thermostat_dhw_extra binary_sensor.thermostat_dhw_extra 6 9 1 7 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime 6 9 15 10 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating 6 9 1 11 1
RC3*0, Moduline 3000/1010H, CW400, Sense II, HPC410 thermostat 158 dhw.dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime 6 9 15 12 1
RC100, CR10, Moduline 1000/1010 thermostat 165 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC100, CR10, Moduline 1000/1010 thermostat 165 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC100, CR10, Moduline 1000/1010 thermostat 165 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC100, CR10, Moduline 1000/1010 thermostat 165 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC100, CR10, Moduline 1000/1010 thermostat 165 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC100, CR10, Moduline 1000/1010 thermostat 165 hc1.mode operating mode enum [off|manual] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
RC100, CR10, Moduline 1000/1010 thermostat 165 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
RC100, CR10, Moduline 1000/1010 thermostat 165 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
Rego 2000/3000 thermostat 172 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Rego 2000/3000 thermostat 172 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Rego 2000/3000 thermostat 172 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
Rego 2000/3000 thermostat 172 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
Rego 2000/3000 thermostat 172 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry 6 0 1 47 1
Rego 2000/3000 thermostat 172 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1/10 48 1
Rego 2000/3000 thermostat 172 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp 6 0 1 49 1
Rego 2000/3000 thermostat 172 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
Rego 2000/3000 thermostat 172 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
Rego 2000/3000 thermostat 172 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
Rego 2000/3000 thermostat 172 solar solar boolean True switch.thermostat_solar switch.thermostat_solar 6 0 1 53 1
Rego 2000/3000 thermostat 172 vacations vacation dates string True sensor.thermostat_vacation_dates sensor.thermostat_vacations 6 0 1 76 13
Rego 2000/3000 thermostat 172 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
Rego 2000/3000 thermostat 172 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
Rego 2000/3000 thermostat 172 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
Rego 2000/3000 thermostat 172 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
Rego 2000/3000 thermostat 172 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
Rego 2000/3000 thermostat 172 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
Rego 2000/3000 thermostat 172 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
Rego 2000/3000 thermostat 172 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw 6 0 1 61 1
Rego 2000/3000 thermostat 172 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat 6 0 1 62 1
Rego 2000/3000 thermostat 172 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool 6 0 1 63 1
Rego 2000/3000 thermostat 172 absent absent boolean True switch.thermostat_absent switch.thermostat_absent 6 0 1 64 1
Rego 2000/3000 thermostat 172 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
Rego 2000/3000 thermostat 172 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
Rego 2000/3000 thermostat 172 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
Rego 2000/3000 thermostat 172 hc1.mode operating mode enum [manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
Rego 2000/3000 thermostat 172 hc1.modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
Rego 2000/3000 thermostat 172 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
Rego 2000/3000 thermostat 172 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
Rego 2000/3000 thermostat 172 hc1.comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp 6 1 1/2 7 1
Rego 2000/3000 thermostat 172 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
Rego 2000/3000 thermostat 172 hc1.designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
Rego 2000/3000 thermostat 172 hc1.offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1 10 1
Rego 2000/3000 thermostat 172 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
Rego 2000/3000 thermostat 172 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
Rego 2000/3000 thermostat 172 hc1.roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
Rego 2000/3000 thermostat 172 hc1.roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 1/10 14 1
Rego 2000/3000 thermostat 172 hc1.curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl 6 1 1/10 15 1
Rego 2000/3000 thermostat 172 hc1.nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
Rego 2000/3000 thermostat 172 hc1.nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
Rego 2000/3000 thermostat 172 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
Rego 2000/3000 thermostat 172 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
Rego 2000/3000 thermostat 172 hc1.summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode 6 1 1 20 1
Rego 2000/3000 thermostat 172 hc1.hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode 6 1 1 21 1
Rego 2000/3000 thermostat 172 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
Rego 2000/3000 thermostat 172 hc1.hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate 6 1 1 23 1
Rego 2000/3000 thermostat 172 hc1.vacationmode vacation mode boolean False binary_sensor.thermostat_hc1_vacation_mode binary_sensor.thermostat_hc1_vacationmode 6 1 1 24 1
Rego 2000/3000 thermostat 172 hc1.controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
Rego 2000/3000 thermostat 172 hc1.program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
Rego 2000/3000 thermostat 172 hc1.tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
Rego 2000/3000 thermostat 172 hc1.cooltemp cooling temperature int8 (>=-1<=30) C True number.thermostat_hc1_cooling_temperature number.thermostat_hc1_cooltemp 6 1 1/2 28 1
Rego 2000/3000 thermostat 172 hc1.fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup 6 1 1 29 1
Rego 2000/3000 thermostat 172 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
Rego 2000/3000 thermostat 172 hc1.reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
Rego 2000/3000 thermostat 172 hc1.noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
Rego 2000/3000 thermostat 172 hc1.reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
Rego 2000/3000 thermostat 172 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
Rego 2000/3000 thermostat 172 hc1.hpcooling hp cooling boolean True switch.thermostat_hc1_hp_cooling switch.thermostat_hc1_hpcooling 6 1 1 35 1
Rego 2000/3000 thermostat 172 hc1.coolingon cooling on boolean False binary_sensor.thermostat_hc1_cooling_on binary_sensor.thermostat_hc1_coolingon 6 1 1 36 1
Rego 2000/3000 thermostat 172 hc1.hpmode HP Mode enum [heating|cooling|heating & cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode 6 1 1 37 1
Rego 2000/3000 thermostat 172 hc1.dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset 6 1 1 38 1
Rego 2000/3000 thermostat 172 hc1.roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff 6 1 1 39 1
Rego 2000/3000 thermostat 172 hc1.hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp 6 1 1 40 1
Rego 2000/3000 thermostat 172 hc1.control control device enum [RC310|RC200|RC100|RC100H|TC100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
Rego 2000/3000 thermostat 172 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
Rego 2000/3000 thermostat 172 hc1.remotehum room humidity from remote cmd [] (>=-1<=101) % True sensor.thermostat_hc1_room_humidity_from_remote sensor.thermostat_hc1_remotehum 6 1 1 43 1
Rego 2000/3000 thermostat 172 hc1.heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay 6 1 1 44 1
Rego 2000/3000 thermostat 172 hc1.heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay 6 1 1 45 1
Rego 2000/3000 thermostat 172 hc1.instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart 6 1 1 46 1
Rego 2000/3000 thermostat 172 hc1.boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost 6 1 1 47 1
Rego 2000/3000 thermostat 172 hc1.boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime 6 1 1 48 1
Rego 2000/3000 thermostat 172 hc1.coolstart cooling starttemp uint8 (>=20<=35) C True number.thermostat_hc1_cooling_starttemp number.thermostat_hc1_coolstart 6 1 1 49 1
Rego 2000/3000 thermostat 172 hc1.coolondelay cooling on delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_on_delay number.thermostat_hc1_coolondelay 6 1 1 50 1
Rego 2000/3000 thermostat 172 hc1.cooloffdelay cooling off delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_off_delay number.thermostat_hc1_cooloffdelay 6 1 1 51 1
Rego 2000/3000 thermostat 172 hc1.switchprogmode switch program mode enum [level|absolute] True select.thermostat_hc1_switch_program_mode select.thermostat_hc1_switchprogmode 6 1 1 52 1
Rego 2000/3000 thermostat 172 hc1.redthreshold reduction threshold int8 (>=12<=22) C True number.thermostat_hc1_reduction_threshold number.thermostat_hc1_redthreshold 6 1 1/2 53 1
Rego 2000/3000 thermostat 172 hc1.solarinfl solar influence uint8 (>=-5<=4294967295) C True number.thermostat_hc1_solar_influence number.thermostat_hc1_solarinfl 6 1 1 54 1
Rego 2000/3000 thermostat 172 hc1.currsolarinfl curent solar influence uint8 (>=0<=25) C False sensor.thermostat_hc1_curent_solar_influence sensor.thermostat_hc1_currsolarinfl 6 1 1/10 55 1
Rego 2000/3000 thermostat 172 dhw.mode operating mode enum [normal|comfort|eco+] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
Rego 2000/3000 thermostat 172 dhw.modetype mode type enum [off|eco|comfort|eco+] False sensor.thermostat_dhw_mode_type sensor.thermostat_dhw_modetype 6 9 1 1 1
Rego 2000/3000 thermostat 172 dhw.settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp 6 9 1 2 1
Rego 2000/3000 thermostat 172 dhw.settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow 6 9 1 3 1
Rego 2000/3000 thermostat 172 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
Rego 2000/3000 thermostat 172 dhw.chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration 6 9 15 5 1
Rego 2000/3000 thermostat 172 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
Rego 2000/3000 thermostat 172 dhw.extra extra boolean False binary_sensor.thermostat_dhw_extra binary_sensor.thermostat_dhw_extra 6 9 1 7 1
Rego 2000/3000 thermostat 172 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
Rego 2000/3000 thermostat 172 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
Rego 2000/3000 thermostat 172 dhw.disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime 6 9 15 10 1
Rego 2000/3000 thermostat 172 dhw.dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating 6 9 1 11 1
Rego 2000/3000 thermostat 172 dhw.dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime 6 9 15 12 1
Comfort RF thermostat 215 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Comfort RF thermostat 215 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Comfort RF thermostat 215 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
Comfort RF thermostat 215 hc1.seltemp selected room temperature int16 (>=-15999<=15999) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp 6 1 1/2 0 1
Comfort RF thermostat 215 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
Comfort RF thermostat 215 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
Comfort RF thermostat 215 hc1.mode operating mode enum [auto|off] False sensor.thermostat_hc1_operating_mode sensor.thermostat_hc1_mode 6 1 1 3 1
Comfort RF thermostat 215 hc1.modetype mode type enum [off|on] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
Comfort RF thermostat 215 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
CRF200S thermostat 216 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
CRF200S thermostat 216 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
CRF200S thermostat 216 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
CRF200S thermostat 216 hc1.seltemp selected room temperature int16 (>=-15999<=15999) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp 6 1 1/2 0 1
CRF200S thermostat 216 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
CRF200S thermostat 216 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
CRF200S thermostat 216 hc1.mode operating mode enum [auto|off] False sensor.thermostat_hc1_operating_mode sensor.thermostat_hc1_mode 6 1 1 3 1
CRF200S thermostat 216 hc1.modetype mode type enum [off|on] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
CRF200S thermostat 216 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
Comfort+2RF thermostat 246 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Comfort+2RF thermostat 246 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Comfort+2RF thermostat 246 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
Comfort+2RF thermostat 246 hc1.seltemp selected room temperature int16 (>=-15999<=15999) C False sensor.thermostat_hc1_selected_room_temperature sensor.thermostat_hc1_seltemp 6 1 1/2 0 1
Comfort+2RF thermostat 246 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
Comfort+2RF thermostat 246 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
Comfort+2RF thermostat 246 hc1.mode operating mode enum [auto|off] False sensor.thermostat_hc1_operating_mode sensor.thermostat_hc1_mode 6 1 1 3 1
Comfort+2RF thermostat 246 hc1.modetype mode type enum [off|on] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
Comfort+2RF thermostat 246 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
Rego 3000, UI800, Logamatic BC400 thermostat 253 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
Rego 3000, UI800, Logamatic BC400 thermostat 253 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
Rego 3000, UI800, Logamatic BC400 thermostat 253 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 floordry floor drying enum [off|start|heat|hold|cool|end] False sensor.thermostat_floor_drying sensor.thermostat_floordry 6 0 1 47 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dampedoutdoortemp damped outdoor temperature int16 (>=-3199<=3199) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1/10 48 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 floordrytemp floor drying temperature uint8 (>=0<=254) C False sensor.thermostat_floor_drying_temperature sensor.thermostat_floordrytemp 6 0 1 49 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 solar solar boolean True switch.thermostat_solar switch.thermostat_solar 6 0 1 53 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 pvenabledhw enable raise dhw boolean True switch.thermostat_enable_raise_dhw switch.thermostat_pvenabledhw 6 0 1 61 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 pvraiseheat raise heating with PV int8 (>=0<=5) K True number.thermostat_raise_heating_with_PV number.thermostat_pvraiseheat 6 0 1 62 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 pvlowercool lower cooling with PV int8 (>=-5<=0) K True number.thermostat_lower_cooling_with_PV number.thermostat_pvlowercool 6 0 1 63 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 absent absent boolean True switch.thermostat_absent switch.thermostat_absent 6 0 1 64 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.mode operating mode enum [off|manual|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.modetype mode type enum [eco|comfort] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.manualtemp manual temperature uint8 (>=0<=127) C True number.thermostat_hc1_manual_temperature number.thermostat_hc1_manualtemp 6 1 1/2 6 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.comforttemp comfort temperature uint8 (>=0<=127) C True number.thermostat_hc1_comfort_temperature number.thermostat_hc1_comforttemp 6 1 1/2 7 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.designtemp design temperature uint8 (>=0<=254) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.offsettemp offset temperature int8 (>=-126<=126) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1 10 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.roominfluence room influence uint8 (>=0<=254) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.roominflfactor room influence factor uint8 (>=0<=25) True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 1/10 14 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.curroominfl current room influence int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_influence sensor.thermostat_hc1_curroominfl 6 1 1/10 15 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.nofrostmode nofrost mode enum [room|outdoor|room outdoor] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.nofrosttemp nofrost temperature int8 (>=-126<=126) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.summersetmode set summer mode enum [summer|auto|winter] True select.thermostat_hc1_set_summer_mode select.thermostat_hc1_summersetmode 6 1 1 20 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.hpoperatingmode heatpump operating mode enum [off|auto|heating|cooling] True select.thermostat_hc1_heatpump_operating_mode select.thermostat_hc1_hpoperatingmode 6 1 1 21 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.hpoperatingstate heatpump operating state enum [heating|off|cooling] False sensor.thermostat_hc1_heatpump_operating_state sensor.thermostat_hc1_hpoperatingstate 6 1 1 23 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.vacationmode vacation mode boolean False binary_sensor.thermostat_hc1_vacation_mode binary_sensor.thermostat_hc1_vacationmode 6 1 1 24 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.controlmode control mode enum [weather compensated|outside basepoint|n/a|room|power|constant] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.program program enum [prog 1|prog 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.tempautotemp temporary set temperature automode int8 (>=-1<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.cooltemp cooling temperature int8 (>=-1<=30) C True number.thermostat_hc1_cooling_temperature number.thermostat_hc1_cooltemp 6 1 1/2 28 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.fastheatup fast heatup uint8 (>=0<=100) % True number.thermostat_hc1_fast_heatup number.thermostat_hc1_fastheatup 6 1 1 29 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.reducemode reduce mode enum [outdoor|room|reduce] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.noreducetemp no reduce below temperature int8 (>=-126<=126) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.reducetemp off/reduce switch temperature int8 (>=-126<=126) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.hpcooling hp cooling boolean True switch.thermostat_hc1_hp_cooling switch.thermostat_hc1_hpcooling 6 1 1 35 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.coolingon cooling on boolean False binary_sensor.thermostat_hc1_cooling_on binary_sensor.thermostat_hc1_coolingon 6 1 1 36 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.hpmode HP Mode enum [heating|cooling|heating & cooling] True select.thermostat_hc1_HP_Mode select.thermostat_hc1_hpmode 6 1 1 37 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.dewoffset dew point offset uint8 (>=2<=10) K True number.thermostat_hc1_dew_point_offset number.thermostat_hc1_dewoffset 6 1 1 38 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.roomtempdiff room temp difference uint8 (>=0<=254) K True number.thermostat_hc1_room_temp_difference number.thermostat_hc1_roomtempdiff 6 1 1 39 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.hpminflowtemp HP min. flow temp. uint8 (>=0<=254) C True number.thermostat_hc1_HP_min._flow_temp. number.thermostat_hc1_hpminflowtemp 6 1 1 40 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.control control device enum [off|-|RC100|RC100H|-|RC120RF|RC220/RT800|single] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.remotehum room humidity from remote cmd [] (>=-1<=101) % True sensor.thermostat_hc1_room_humidity_from_remote sensor.thermostat_hc1_remotehum 6 1 1 43 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.heatondelay heat-on delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-on_delay number.thermostat_hc1_heatondelay 6 1 1 44 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.heatoffdelay heat-off delay uint8 (>=1<=48) hours True number.thermostat_hc1_heat-off_delay number.thermostat_hc1_heatoffdelay 6 1 1 45 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.instantstart instant start uint8 (>=1<=10) K True number.thermostat_hc1_instant_start number.thermostat_hc1_instantstart 6 1 1 46 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.boost boost mode boolean True switch.thermostat_hc1_boost_mode switch.thermostat_hc1_boost 6 1 1 47 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.boosttime boost time uint8 (>=0<=254) hours True number.thermostat_hc1_boost_time number.thermostat_hc1_boosttime 6 1 1 48 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.coolstart cooling starttemp uint8 (>=20<=35) C True number.thermostat_hc1_cooling_starttemp number.thermostat_hc1_coolstart 6 1 1 49 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.coolondelay cooling on delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_on_delay number.thermostat_hc1_coolondelay 6 1 1 50 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.cooloffdelay cooling off delay uint8 (>=1<=48) hours True number.thermostat_hc1_cooling_off_delay number.thermostat_hc1_cooloffdelay 6 1 1 51 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.switchprogmode switch program mode enum [level|absolute] True select.thermostat_hc1_switch_program_mode select.thermostat_hc1_switchprogmode 6 1 1 52 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.redthreshold reduction threshold int8 (>=12<=22) C True number.thermostat_hc1_reduction_threshold number.thermostat_hc1_redthreshold 6 1 1/2 53 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.solarinfl solar influence uint8 (>=-5<=4294967295) C True number.thermostat_hc1_solar_influence number.thermostat_hc1_solarinfl 6 1 1 54 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 hc1.currsolarinfl curent solar influence uint8 (>=0<=25) C False sensor.thermostat_hc1_curent_solar_influence sensor.thermostat_hc1_currsolarinfl 6 1 1/10 55 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.mode operating mode enum [off|eco+|eco|comfort|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.modetype mode type enum [off|eco|comfort|eco+] False sensor.thermostat_dhw_mode_type sensor.thermostat_dhw_modetype 6 9 1 1 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.settemp set temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_temperature number.thermostat_dhw_settemp 6 9 1 2 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.settemplow set low temperature uint8 (>=0<=254) C True number.thermostat_dhw_set_low_temperature number.thermostat_dhw_settemplow 6 9 1 3 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.chargeduration charge duration uint8 (>=0<=3810) minutes True number.thermostat_dhw_charge_duration number.thermostat_dhw_chargeduration 6 9 15 5 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.extra extra boolean False binary_sensor.thermostat_dhw_extra binary_sensor.thermostat_dhw_extra 6 9 1 7 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.disinfecttime disinfection time uint8 (>=0<=1431) minutes True number.thermostat_dhw_disinfection_time number.thermostat_dhw_disinfecttime 6 9 15 10 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.dailyheating daily heating boolean True switch.thermostat_dhw_daily_heating switch.thermostat_dhw_dailyheating 6 9 1 11 1
Rego 3000, UI800, Logamatic BC400 thermostat 253 dhw.dailyheattime daily heating time uint8 (>=0<=1431) minutes True number.thermostat_dhw_daily_heating_time number.thermostat_dhw_dailyheattime 6 9 15 12 1
ES72, RC20 thermostat 66 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
ES72, RC20 thermostat 66 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
ES72, RC20 thermostat 66 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
ES72, RC20 thermostat 66 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
ES72, RC20 thermostat 66 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
ES72, RC20 thermostat 66 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
ES72, RC20 thermostat 66 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
ES72, RC20 thermostat 66 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
ES72, RC20 thermostat 66 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
ES72, RC20 thermostat 66 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
ES72, RC20 thermostat 66 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
ES72, RC20 thermostat 66 hc1.program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
ES72, RC20 thermostat 66 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
ES72, RC20 thermostat 66 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
ES72, RC20 thermostat 66 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
ES72, RC20 thermostat 66 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
ES72, RC20 thermostat 66 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
ES72, RC20 thermostat 66 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
ES73 thermostat 76 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
ES73 thermostat 76 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
ES73 thermostat 76 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
ES73 thermostat 76 display display enum [internal temperature|internal setpoint|external temperature|burner temperature|dhw temperature|functioning mode|time|date|smoke temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
ES73 thermostat 76 language language enum [german|dutch|french|italian] False sensor.thermostat_language sensor.thermostat_language 6 0 1 66 1
ES73 thermostat 76 clockoffset clock offset int8 (>=-126<=126) seconds True number.thermostat_clock_offset number.thermostat_clockoffset 6 0 1 67 1
ES73 thermostat 76 intoffset internal temperature offset int8 (>=-12<=12) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
ES73 thermostat 76 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
ES73 thermostat 76 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1 6 0 1/10 68 1
ES73 thermostat 76 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2 6 0 1/10 69 1
ES73 thermostat 76 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
ES73 thermostat 76 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1 48 1
ES73 thermostat 76 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
ES73 thermostat 76 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
ES73 thermostat 76 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
ES73 thermostat 76 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
ES73 thermostat 76 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
ES73 thermostat 76 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
ES73 thermostat 76 hc1.daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
ES73 thermostat 76 hc1.nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
ES73 thermostat 76 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
ES73 thermostat 76 hc1.offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1/2 10 1
ES73 thermostat 76 hc1.holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp 6 1 1/2 58 1
ES73 thermostat 76 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
ES73 thermostat 76 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
ES73 thermostat 76 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
ES73 thermostat 76 hc1.holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode 6 1 1 59 1
ES73 thermostat 76 hc1.nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
ES73 thermostat 76 hc1.nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
ES73 thermostat 76 hc1.roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
ES73 thermostat 76 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
ES73 thermostat 76 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
ES73 thermostat 76 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset 6 1 1 60 1
ES73 thermostat 76 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
ES73 thermostat 76 hc1.reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
ES73 thermostat 76 hc1.controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
ES73 thermostat 76 hc1.control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
ES73 thermostat 76 hc1.holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays 6 1 1 61 13
ES73 thermostat 76 hc1.vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations 6 1 1 74 13
ES73 thermostat 76 hc1.program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
ES73 thermostat 76 hc1.pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause 6 1 1 87 1
ES73 thermostat 76 hc1.party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party 6 1 1 88 1
ES73 thermostat 76 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
ES73 thermostat 76 hc1.noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
ES73 thermostat 76 hc1.reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
ES73 thermostat 76 hc1.vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp 6 1 1 89 1
ES73 thermostat 76 hc1.vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode 6 1 1 90 1
ES73 thermostat 76 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
ES73 thermostat 76 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
ES73 thermostat 76 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
ES73 thermostat 76 hc1.switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1 6 1 1 91 8
ES73 thermostat 76 hc1.switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2 6 1 1 99 8
ES73 thermostat 76 dhw.mode operating mode enum [off|on|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
ES73 thermostat 76 dhw.circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
ES73 thermostat 76 dhw.progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode 6 9 1 13 1
ES73 thermostat 76 dhw.circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog 6 9 1 14 1
ES73 thermostat 76 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
ES73 thermostat 76 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
ES73 thermostat 76 dhw.disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour 6 9 1 15 1
ES73 thermostat 76 dhw.maxtemp maximum temperature uint8 (>=0<=254) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp 6 9 1 16 1
ES73 thermostat 76 dhw.onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey 6 9 1 17 1
ES73 thermostat 76 dhw.switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime 6 9 1 18 8
ES73 thermostat 76 dhw.circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime 6 9 1 26 8
ES73 thermostat 76 dhw.holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays 6 9 1 34 13
ES73 thermostat 76 dhw.vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations 6 9 1 47 13
ES72, RC20 thermostat 113 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
ES72, RC20 thermostat 113 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
ES72, RC20 thermostat 113 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
ES72, RC20 thermostat 113 minexttemp minimal external temperature int8 (>=-126<=126) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
ES72, RC20 thermostat 113 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
ES72, RC20 thermostat 113 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
ES72, RC20 thermostat 113 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
ES72, RC20 thermostat 113 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
ES72, RC20 thermostat 113 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
ES72, RC20 thermostat 113 hc1.daytemp day temperature uint8 (>=0<=127) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
ES72, RC20 thermostat 113 hc1.nighttemp night temperature uint8 (>=0<=127) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
ES72, RC20 thermostat 113 hc1.program program enum [family|morning|evening|am|pm|midday|singles|seniors] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
ES72, RC20 thermostat 113 hc1.minflowtemp min flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
ES72, RC20 thermostat 113 hc1.maxflowtemp max flow temperature uint8 (>=0<=254) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
ES72, RC20 thermostat 113 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=127) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
ES72, RC20 thermostat 113 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
ES72, RC20 thermostat 113 hc1.summertemp summer temperature uint8 (>=10<=30) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
ES72, RC20 thermostat 113 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
ES79 thermostat 156 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
ES79 thermostat 156 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
ES79 thermostat 156 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
ES79 thermostat 156 intoffset internal temperature offset int8 (>=-5<=5) C True number.thermostat_internal_temperature_offset number.thermostat_intoffset 6 0 1/10 46 1
ES79 thermostat 156 minexttemp minimal external temperature int8 (>=-30<=0) C True number.thermostat_minimal_external_temperature number.thermostat_minexttemp 6 0 1 51 1
ES79 thermostat 156 inttemp1 temperature sensor 1 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_1 sensor.thermostat_inttemp1 6 0 1/10 68 1
ES79 thermostat 156 inttemp2 temperature sensor 2 int16 (>=-3199<=3199) C False sensor.thermostat_temperature_sensor_2 sensor.thermostat_inttemp2 6 0 1/10 69 1
ES79 thermostat 156 damping damping outdoor temperature boolean True switch.thermostat_damping_outdoor_temperature switch.thermostat_damping 6 0 1 52 1
ES79 thermostat 156 dampedoutdoortemp damped outdoor temperature int8 (>=-126<=126) C False sensor.thermostat_damped_outdoor_temperature sensor.thermostat_dampedoutdoortemp 6 0 1 48 1
ES79 thermostat 156 building building type enum [light|medium|heavy] True select.thermostat_building_type select.thermostat_building 6 0 1 50 1
ES79 thermostat 156 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
ES79 thermostat 156 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
ES79 thermostat 156 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
ES79 thermostat 156 hc1.mode operating mode enum [night|day|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
ES79 thermostat 156 hc1.modetype mode type enum [night|day] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
ES79 thermostat 156 hc1.daytemp day temperature uint8 (>=10<=30) C True number.thermostat_hc1_day_temperature number.thermostat_hc1_daytemp 6 1 1/2 56 1
ES79 thermostat 156 hc1.nighttemp night temperature uint8 (>=10<=30) C True number.thermostat_hc1_night_temperature number.thermostat_hc1_nighttemp 6 1 1/2 57 1
ES79 thermostat 156 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
ES79 thermostat 156 hc1.offsettemp offset temperature int8 (>=-5<=5) C True number.thermostat_hc1_offset_temperature number.thermostat_hc1_offsettemp 6 1 1/2 10 1
ES79 thermostat 156 hc1.holidaytemp holiday temperature uint8 (>=5<=30) C True number.thermostat_hc1_holiday_temperature number.thermostat_hc1_holidaytemp 6 1 1/2 58 1
ES79 thermostat 156 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
ES79 thermostat 156 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1 8 1
ES79 thermostat 156 hc1.summermode summer mode enum [winter|summer] False sensor.thermostat_hc1_summer_mode sensor.thermostat_hc1_summermode 6 1 1 22 1
ES79 thermostat 156 hc1.holidaymode holiday mode boolean False binary_sensor.thermostat_hc1_holiday_mode binary_sensor.thermostat_hc1_holidaymode 6 1 1 59 1
ES79 thermostat 156 hc1.nofrosttemp nofrost temperature int8 (>=-20<=10) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1 17 1
ES79 thermostat 156 hc1.nofrostmode nofrost mode enum [off|outdoor|room] True select.thermostat_hc1_nofrost_mode select.thermostat_hc1_nofrostmode 6 1 1 16 1
ES79 thermostat 156 hc1.roominfluence room influence uint8 (>=0<=10) C True number.thermostat_hc1_room_influence number.thermostat_hc1_roominfluence 6 1 1 13 1
ES79 thermostat 156 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
ES79 thermostat 156 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
ES79 thermostat 156 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) C True number.thermostat_hc1_flow_temperature_offset_for_mixer number.thermostat_hc1_flowtempoffset 6 1 1 60 1
ES79 thermostat 156 hc1.heatingtype heating type enum [off|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
ES79 thermostat 156 hc1.reducemode reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_reduce_mode select.thermostat_hc1_reducemode 6 1 1 31 1
ES79 thermostat 156 hc1.controlmode control mode enum [outdoor|room] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
ES79 thermostat 156 hc1.control control device enum [off|RC20|RC3x] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
ES79 thermostat 156 hc1.holidays holiday dates string True sensor.thermostat_hc1_holiday_dates sensor.thermostat_hc1_holidays 6 1 1 61 13
ES79 thermostat 156 hc1.vacations vacation dates string True sensor.thermostat_hc1_vacation_dates sensor.thermostat_hc1_vacations 6 1 1 74 13
ES79 thermostat 156 hc1.program program enum [own 1|family|morning|evening|am|pm|midday|singles|seniors|new|own 2] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
ES79 thermostat 156 hc1.pause pause time uint8 (>=0<=99) hours True number.thermostat_hc1_pause_time number.thermostat_hc1_pause 6 1 1 87 1
ES79 thermostat 156 hc1.party party time uint8 (>=0<=99) hours True number.thermostat_hc1_party_time number.thermostat_hc1_party 6 1 1 88 1
ES79 thermostat 156 hc1.tempautotemp temporary set temperature automode uint8 (>=0<=30) C True number.thermostat_hc1_temporary_set_temperature_automode number.thermostat_hc1_tempautotemp 6 1 1/2 27 1
ES79 thermostat 156 hc1.noreducetemp no reduce below temperature int8 (>=-31<=10) C True number.thermostat_hc1_no_reduce_below_temperature number.thermostat_hc1_noreducetemp 6 1 1 32 1
ES79 thermostat 156 hc1.reducetemp off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_off/reduce_switch_temperature number.thermostat_hc1_reducetemp 6 1 1 33 1
ES79 thermostat 156 hc1.vacreducetemp vacations off/reduce switch temperature int8 (>=-20<=10) C True number.thermostat_hc1_vacations_off/reduce_switch_temperature number.thermostat_hc1_vacreducetemp 6 1 1 89 1
ES79 thermostat 156 hc1.vacreducemode vacations reduce mode enum [nofrost|reduce|room|outdoor] True select.thermostat_hc1_vacations_reduce_mode select.thermostat_hc1_vacreducemode 6 1 1 90 1
ES79 thermostat 156 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
ES79 thermostat 156 hc1.dhwprio dhw priority boolean True switch.thermostat_hc1_dhw_priority switch.thermostat_hc1_dhwprio 6 1 1 34 1
ES79 thermostat 156 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
ES79 thermostat 156 hc1.switchtime1 own1 program switchtime string True sensor.thermostat_hc1_own1_program_switchtime sensor.thermostat_hc1_switchtime1 6 1 1 91 8
ES79 thermostat 156 hc1.switchtime2 own2 program switchtime string True sensor.thermostat_hc1_own2_program_switchtime sensor.thermostat_hc1_switchtime2 6 1 1 99 8
ES79 thermostat 156 dhw.mode operating mode enum [off|on|auto] True select.thermostat_dhw_operating_mode select.thermostat_dhw_mode 6 9 1 0 1
ES79 thermostat 156 dhw.circmode circulation pump mode enum [off|on|auto] True select.thermostat_dhw_circulation_pump_mode select.thermostat_dhw_circmode 6 9 1 4 1
ES79 thermostat 156 dhw.progmode program enum [std prog|own prog] True select.thermostat_dhw_program select.thermostat_dhw_progmode 6 9 1 13 1
ES79 thermostat 156 dhw.circprog circulation program enum [std prog|own prog] True select.thermostat_dhw_circulation_program select.thermostat_dhw_circprog 6 9 1 14 1
ES79 thermostat 156 dhw.disinfecting disinfecting boolean True switch.thermostat_dhw_disinfecting switch.thermostat_dhw_disinfecting 6 9 1 8 1
ES79 thermostat 156 dhw.disinfectday disinfection day enum [mo|tu|we|th|fr|sa|su|all] True select.thermostat_dhw_disinfection_day select.thermostat_dhw_disinfectday 6 9 1 9 1
ES79 thermostat 156 dhw.disinfecthour disinfection hour uint8 (>=0<=23) True number.thermostat_dhw_disinfection_hour number.thermostat_dhw_disinfecthour 6 9 1 15 1
ES79 thermostat 156 dhw.maxtemp maximum temperature uint8 (>=60<=80) C True number.thermostat_dhw_maximum_temperature number.thermostat_dhw_maxtemp 6 9 1 16 1
ES79 thermostat 156 dhw.onetimekey one time key function boolean True switch.thermostat_dhw_one_time_key_function switch.thermostat_dhw_onetimekey 6 9 1 17 1
ES79 thermostat 156 dhw.switchtime program switchtime string True sensor.thermostat_dhw_program_switchtime sensor.thermostat_dhw_switchtime 6 9 1 18 8
ES79 thermostat 156 dhw.circswitchtime circulation program switchtime string True sensor.thermostat_dhw_circulation_program_switchtime sensor.thermostat_dhw_circswitchtime 6 9 1 26 8
ES79 thermostat 156 dhw.holidays holiday dates string True sensor.thermostat_dhw_holiday_dates sensor.thermostat_dhw_holidays 6 9 1 34 13
ES79 thermostat 156 dhw.vacations vacation dates string True sensor.thermostat_dhw_vacation_dates sensor.thermostat_dhw_vacations 6 9 1 47 13
FW100 thermostat 105 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FW100 thermostat 105 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FW100 thermostat 105 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FW100 thermostat 105 display display enum [dhw temperature|date|external temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
FW100 thermostat 105 language language enum [german|italian|french|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
FW100 thermostat 105 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FW100 thermostat 105 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FW100 thermostat 105 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FW100 thermostat 105 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FW100 thermostat 105 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FW100 thermostat 105 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FW100 thermostat 105 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FW100 thermostat 105 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FW100 thermostat 105 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FW100 thermostat 105 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FW100 thermostat 105 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FW100 thermostat 105 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FW100 thermostat 105 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FW100 thermostat 105 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FW100 thermostat 105 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FW100 thermostat 105 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FW100 thermostat 105 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FW100 thermostat 105 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FW100 thermostat 105 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FW100 thermostat 105 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FW100 thermostat 105 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FW100 thermostat 105 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FW100 thermostat 105 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FW100 thermostat 105 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FW100 thermostat 105 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FW100 thermostat 105 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FW100 thermostat 105 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FW100 thermostat 105 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FW100 thermostat 105 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FW100 thermostat 105 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FW100 thermostat 105 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FW100 thermostat 105 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FW200 thermostat 106 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FW200 thermostat 106 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FW200 thermostat 106 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FW200 thermostat 106 display display enum [dhw temperature|date|external temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
FW200 thermostat 106 language language enum [german|italian|french|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
FW200 thermostat 106 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FW200 thermostat 106 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FW200 thermostat 106 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FW200 thermostat 106 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FW200 thermostat 106 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FW200 thermostat 106 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FW200 thermostat 106 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FW200 thermostat 106 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FW200 thermostat 106 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FW200 thermostat 106 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FW200 thermostat 106 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FW200 thermostat 106 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FW200 thermostat 106 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FW200 thermostat 106 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FW200 thermostat 106 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FW200 thermostat 106 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FW200 thermostat 106 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FW200 thermostat 106 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FW200 thermostat 106 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FW200 thermostat 106 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FW200 thermostat 106 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FW200 thermostat 106 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FW200 thermostat 106 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FW200 thermostat 106 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FW200 thermostat 106 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FW200 thermostat 106 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FW200 thermostat 106 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FW200 thermostat 106 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FW200 thermostat 106 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FW200 thermostat 106 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FW200 thermostat 106 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FW200 thermostat 106 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FR100 thermostat 107 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FR100 thermostat 107 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FR100 thermostat 107 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FR100 thermostat 107 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FR100 thermostat 107 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FR100 thermostat 107 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FR100 thermostat 107 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FR100 thermostat 107 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FR100 thermostat 107 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FR100 thermostat 107 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FR100 thermostat 107 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FR100 thermostat 107 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FR100 thermostat 107 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FR100 thermostat 107 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FR100 thermostat 107 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FR100 thermostat 107 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FR100 thermostat 107 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FR100 thermostat 107 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FR100 thermostat 107 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FR100 thermostat 107 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FR100 thermostat 107 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FR100 thermostat 107 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FR100 thermostat 107 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FR100 thermostat 107 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FR100 thermostat 107 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FR100 thermostat 107 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FR100 thermostat 107 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FR100 thermostat 107 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FR100 thermostat 107 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FR100 thermostat 107 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FR100 thermostat 107 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FR100 thermostat 107 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FR100 thermostat 107 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FR100 thermostat 107 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FR100 thermostat 107 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FR110 thermostat 108 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FR110 thermostat 108 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FR110 thermostat 108 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FR110 thermostat 108 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FR110 thermostat 108 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FR110 thermostat 108 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FR110 thermostat 108 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FR110 thermostat 108 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FR110 thermostat 108 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FR110 thermostat 108 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FR110 thermostat 108 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FR110 thermostat 108 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FR110 thermostat 108 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FR110 thermostat 108 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FR110 thermostat 108 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FR110 thermostat 108 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FR110 thermostat 108 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FR110 thermostat 108 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FR110 thermostat 108 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FR110 thermostat 108 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FR110 thermostat 108 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FR110 thermostat 108 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FR110 thermostat 108 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FR110 thermostat 108 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FR110 thermostat 108 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FR110 thermostat 108 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FR110 thermostat 108 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FR110 thermostat 108 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FR110 thermostat 108 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FR110 thermostat 108 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FR110 thermostat 108 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FR110 thermostat 108 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FR110 thermostat 108 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FR110 thermostat 108 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FR110 thermostat 108 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FB10 thermostat 109 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FB10 thermostat 109 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FB10 thermostat 109 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FB10 thermostat 109 display display enum [dhw temperature|date|external temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
FB10 thermostat 109 language language enum [german|italian|french|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
FB10 thermostat 109 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FB10 thermostat 109 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FB10 thermostat 109 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FB10 thermostat 109 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FB10 thermostat 109 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FB10 thermostat 109 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FB10 thermostat 109 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FB10 thermostat 109 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FB10 thermostat 109 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FB10 thermostat 109 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FB10 thermostat 109 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FB10 thermostat 109 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FB10 thermostat 109 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FB10 thermostat 109 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FB10 thermostat 109 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FB10 thermostat 109 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FB10 thermostat 109 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FB10 thermostat 109 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FB10 thermostat 109 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FB10 thermostat 109 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FB10 thermostat 109 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FB10 thermostat 109 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FB10 thermostat 109 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FB10 thermostat 109 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FB10 thermostat 109 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FB10 thermostat 109 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FB10 thermostat 109 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FB10 thermostat 109 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FB10 thermostat 109 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FB10 thermostat 109 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FB10 thermostat 109 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FB10 thermostat 109 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FB100 thermostat 110 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FB100 thermostat 110 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FB100 thermostat 110 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FB100 thermostat 110 display display enum [dhw temperature|date|external temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
FB100 thermostat 110 language language enum [german|italian|french|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
FB100 thermostat 110 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FB100 thermostat 110 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FB100 thermostat 110 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FB100 thermostat 110 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FB100 thermostat 110 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FB100 thermostat 110 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FB100 thermostat 110 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FB100 thermostat 110 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FB100 thermostat 110 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FB100 thermostat 110 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FB100 thermostat 110 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FB100 thermostat 110 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FB100 thermostat 110 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FB100 thermostat 110 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FB100 thermostat 110 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FB100 thermostat 110 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FB100 thermostat 110 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FB100 thermostat 110 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FB100 thermostat 110 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FB100 thermostat 110 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FB100 thermostat 110 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FB100 thermostat 110 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FB100 thermostat 110 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FB100 thermostat 110 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FB100 thermostat 110 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FB100 thermostat 110 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FB100 thermostat 110 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FB100 thermostat 110 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FB100 thermostat 110 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FB100 thermostat 110 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FB100 thermostat 110 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FB100 thermostat 110 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FR10 thermostat 111 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FR10 thermostat 111 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FR10 thermostat 111 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FR10 thermostat 111 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FR10 thermostat 111 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FR10 thermostat 111 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FR10 thermostat 111 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FR10 thermostat 111 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FR10 thermostat 111 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FR10 thermostat 111 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FR10 thermostat 111 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FR10 thermostat 111 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FR10 thermostat 111 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FR10 thermostat 111 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FR10 thermostat 111 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FR10 thermostat 111 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FR10 thermostat 111 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FR10 thermostat 111 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FR10 thermostat 111 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FR10 thermostat 111 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FR10 thermostat 111 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FR10 thermostat 111 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FR10 thermostat 111 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FR10 thermostat 111 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FR10 thermostat 111 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FR10 thermostat 111 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FR10 thermostat 111 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FR10 thermostat 111 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FR10 thermostat 111 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FR10 thermostat 111 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FR10 thermostat 111 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FR10 thermostat 111 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FR10 thermostat 111 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FR10 thermostat 111 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FR10 thermostat 111 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FW500 thermostat 116 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FW500 thermostat 116 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FW500 thermostat 116 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FW500 thermostat 116 display display enum [dhw temperature|date|external temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
FW500 thermostat 116 language language enum [german|italian|french|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
FW500 thermostat 116 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FW500 thermostat 116 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FW500 thermostat 116 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FW500 thermostat 116 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FW500 thermostat 116 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FW500 thermostat 116 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FW500 thermostat 116 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FW500 thermostat 116 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FW500 thermostat 116 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FW500 thermostat 116 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FW500 thermostat 116 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FW500 thermostat 116 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FW500 thermostat 116 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FW500 thermostat 116 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FW500 thermostat 116 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FW500 thermostat 116 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FW500 thermostat 116 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FW500 thermostat 116 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FW500 thermostat 116 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FW500 thermostat 116 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FW500 thermostat 116 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FW500 thermostat 116 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FW500 thermostat 116 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FW500 thermostat 116 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FW500 thermostat 116 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FW500 thermostat 116 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FW500 thermostat 116 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FW500 thermostat 116 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FW500 thermostat 116 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FW500 thermostat 116 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FW500 thermostat 116 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FW500 thermostat 116 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FR50 thermostat 147 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FR50 thermostat 147 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FR50 thermostat 147 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FR50 thermostat 147 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FR50 thermostat 147 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FR50 thermostat 147 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FR50 thermostat 147 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FR50 thermostat 147 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FR50 thermostat 147 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FR50 thermostat 147 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FR50 thermostat 147 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FR50 thermostat 147 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FR50 thermostat 147 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FR50 thermostat 147 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FR50 thermostat 147 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FR50 thermostat 147 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FR50 thermostat 147 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FR50 thermostat 147 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FR50 thermostat 147 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FR50 thermostat 147 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FR50 thermostat 147 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FR50 thermostat 147 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FR50 thermostat 147 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FR50 thermostat 147 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FR50 thermostat 147 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FR50 thermostat 147 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FR50 thermostat 147 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FR50 thermostat 147 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FR50 thermostat 147 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FR50 thermostat 147 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FR50 thermostat 147 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FR50 thermostat 147 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FR50 thermostat 147 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FR50 thermostat 147 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FR50 thermostat 147 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FR120 thermostat 191 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FR120 thermostat 191 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FR120 thermostat 191 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FR120 thermostat 191 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FR120 thermostat 191 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FR120 thermostat 191 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FR120 thermostat 191 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FR120 thermostat 191 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FR120 thermostat 191 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FR120 thermostat 191 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FR120 thermostat 191 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FR120 thermostat 191 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FR120 thermostat 191 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FR120 thermostat 191 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FR120 thermostat 191 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FR120 thermostat 191 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FR120 thermostat 191 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FR120 thermostat 191 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FR120 thermostat 191 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FR120 thermostat 191 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FR120 thermostat 191 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FR120 thermostat 191 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FR120 thermostat 191 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FR120 thermostat 191 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FR120 thermostat 191 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FR120 thermostat 191 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FR120 thermostat 191 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FR120 thermostat 191 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FR120 thermostat 191 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FR120 thermostat 191 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FR120 thermostat 191 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FR120 thermostat 191 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FR120 thermostat 191 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FR120 thermostat 191 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FR120 thermostat 191 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
FW120 thermostat 192 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
FW120 thermostat 192 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
FW120 thermostat 192 datetime date/time string True sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
FW120 thermostat 192 display display enum [dhw temperature|date|external temperature] True select.thermostat_display select.thermostat_display 6 0 1 65 1
FW120 thermostat 192 language language enum [german|italian|french|dutch] True select.thermostat_language select.thermostat_language 6 0 1 66 1
FW120 thermostat 192 hybridstrategy hybrid control strategy enum [co2 optimized|cost optimized|outside temp switched|co2 cost mix] True select.thermostat_hybrid_control_strategy select.thermostat_hybridstrategy 6 0 1 54 1
FW120 thermostat 192 switchovertemp outside switchover temperature int8 (>=-20<=20) C True number.thermostat_outside_switchover_temperature number.thermostat_switchovertemp 6 0 1 55 1
FW120 thermostat 192 energycostratio energy cost ratio uint8 (>=0<=20) True number.thermostat_energy_cost_ratio number.thermostat_energycostratio 6 0 1/10 56 1
FW120 thermostat 192 fossilefactor fossile energy factor uint8 (>=0<=5) True number.thermostat_fossile_energy_factor number.thermostat_fossilefactor 6 0 1/10 57 1
FW120 thermostat 192 electricfactor electric energy factor uint8 (>=0<=5) True number.thermostat_electric_energy_factor number.thermostat_electricfactor 6 0 1/10 58 1
FW120 thermostat 192 delayboiler delay boiler support uint8 (>=5<=120) minutes True number.thermostat_delay_boiler_support number.thermostat_delayboiler 6 0 1 59 1
FW120 thermostat 192 tempdiffboiler temp diff boiler support uint8 (>=1<=99) C True number.thermostat_temp_diff_boiler_support number.thermostat_tempdiffboiler 6 0 1 60 1
FW120 thermostat 192 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/10 0 1
FW120 thermostat 192 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
FW120 thermostat 192 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
FW120 thermostat 192 hc1.mode operating mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_operating_mode select.thermostat_hc1_mode 6 1 1 3 1
FW120 thermostat 192 hc1.modetype mode type enum [nofrost|eco|heat] False sensor.thermostat_hc1_mode_type sensor.thermostat_hc1_modetype 6 1 1 4 1
FW120 thermostat 192 hc1.heattemp heat temperature uint8 (>=0<=127) C True number.thermostat_hc1_heat_temperature number.thermostat_hc1_heattemp 6 1 1/2 198 1
FW120 thermostat 192 hc1.ecotemp eco temperature uint8 (>=0<=127) C True number.thermostat_hc1_eco_temperature number.thermostat_hc1_ecotemp 6 1 1/2 5 1
FW120 thermostat 192 hc1.nofrosttemp nofrost temperature int8 (>=-63<=63) C True number.thermostat_hc1_nofrost_temperature number.thermostat_hc1_nofrosttemp 6 1 1/2 17 1
FW120 thermostat 192 hc1.control control device enum [off|FB10|FB100] True select.thermostat_hc1_control_device select.thermostat_hc1_control 6 1 1 41 1
FW120 thermostat 192 hc1.program program enum [prog a|prog b|prog c|prog d|prog e|prog f] True select.thermostat_hc1_program select.thermostat_hc1_program 6 1 1 26 1
FW120 thermostat 192 hc1.remotetemp room temperature from remote cmd [] (>=-1<=101) C True sensor.thermostat_hc1_room_temperature_from_remote sensor.thermostat_hc1_remotetemp 6 1 1/10 42 1
FW120 thermostat 192 hc1.targetflowtemp target flow temperature uint8 (>=0<=254) C False sensor.thermostat_hc1_target_flow_temperature sensor.thermostat_hc1_targetflowtemp 6 1 1 18 1
FW120 thermostat 192 hc1.summertemp summer temperature uint8 (>=9<=25) C True number.thermostat_hc1_summer_temperature number.thermostat_hc1_summertemp 6 1 1/2 8 1
FW120 thermostat 192 hc1.roomsensor room sensor enum [extern|intern|auto] True select.thermostat_hc1_room_sensor select.thermostat_hc1_roomsensor 6 1 1 199 1
FW120 thermostat 192 hc1.holidaymode holiday mode enum [nofrost|eco|heat|auto] True select.thermostat_hc1_holiday_mode select.thermostat_hc1_holidaymode 6 1 1 59 1
FW120 thermostat 192 hc1.switchonoptimization switch-on optimization boolean True switch.thermostat_hc1_switch-on_optimization switch.thermostat_hc1_switchonoptimization 6 1 1 30 1
FW120 thermostat 192 hc1.heatup heatup enum [slow|medium|fast] True select.thermostat_hc1_heatup select.thermostat_hc1_heatup 6 1 1 200 1
FW120 thermostat 192 hc1.minflowtemp min flow temperature uint8 (>=5<=70) C True number.thermostat_hc1_min_flow_temperature number.thermostat_hc1_minflowtemp 6 1 1 11 1
FW120 thermostat 192 hc1.maxflowtemp max flow temperature uint8 (>=30<=90) C True number.thermostat_hc1_max_flow_temperature number.thermostat_hc1_maxflowtemp 6 1 1 12 1
FW120 thermostat 192 hc1.designtemp design temperature uint8 (>=30<=90) C True number.thermostat_hc1_design_temperature number.thermostat_hc1_designtemp 6 1 1 9 1
FW120 thermostat 192 hc1.roominfluence room influence enum [off|intern|extern|auto] True select.thermostat_hc1_room_influence select.thermostat_hc1_roominfluence 6 1 1 13 1
FW120 thermostat 192 hc1.roominflfactor room influence factor uint8 (>=0<=100) % True number.thermostat_hc1_room_influence_factor number.thermostat_hc1_roominflfactor 6 1 10 14 1
FW120 thermostat 192 hc1.heatingtype heating type enum [off|heatingcurve|radiator|convector|floor] True select.thermostat_hc1_heating_type select.thermostat_hc1_heatingtype 6 1 1 19 1
FW120 thermostat 192 hc1.controlmode control mode enum [off|unmixed|unmixed IPM|mixed IPM] True select.thermostat_hc1_control_mode select.thermostat_hc1_controlmode 6 1 1 25 1
FW120 thermostat 192 dhw.charge charge boolean True switch.thermostat_dhw_charge switch.thermostat_dhw_charge 6 9 1 6 1
RT800, RC220 thermostat 3 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RT800, RC220 thermostat 3 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RT800, RC220 thermostat 3 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RT800, RC220 thermostat 3 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RT800, RC220 thermostat 3 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RT800, RC220 thermostat 3 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
RC100H, CR10H thermostat 200 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
RC100H, CR10H thermostat 200 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
RC100H, CR10H thermostat 200 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
RC100H, CR10H thermostat 200 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
RC100H, CR10H thermostat 200 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
RC100H, CR10H thermostat 200 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
TR120RF, CR20RF thermostat 249 errorcode error code string False sensor.thermostat_error_code sensor.thermostat_errorcode 6 0 1 0 8
TR120RF, CR20RF thermostat 249 lastcode last error code string False sensor.thermostat_last_error_code sensor.thermostat_lastcode 6 0 1 8 25
TR120RF, CR20RF thermostat 249 datetime date/time string False sensor.thermostat_date/time sensor.thermostat_datetime 6 0 1 33 13
TR120RF, CR20RF thermostat 249 hc1.seltemp selected room temperature int16 (>=0<=30) C True number.thermostat_hc1_selected_room_temperature number.thermostat_hc1_seltemp 6 1 1/2 0 1
TR120RF, CR20RF thermostat 249 hc1.currtemp current room temperature int16 (>=-3199<=3199) C False sensor.thermostat_hc1_current_room_temperature sensor.thermostat_hc1_currtemp 6 1 1/10 1 1
TR120RF, CR20RF thermostat 249 hc1.haclimate mqtt discovery current room temperature enum [selTemp|roomTemp] (>=5<=30) False sensor.thermostat_hc1_mqtt_discovery_current_room_temperature sensor.thermostat_hc1_haclimate 6 1 1 2 1
XCUMixer mixer 8 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
XCUMixer mixer 8 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
XCUMixer mixer 8 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
XCUMixer mixer 8 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
XCUMixer mixer 8 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
XCUMixer mixer 8 hc1.flow Durchfluss uint16 (>=0<=31999) l/h False sensor.mixer_hc1_Durchfluss sensor.mixer_hc1_flow 7 1 1 5 1
XCUMixer mixer 8 hc1.setdiffpress set differential pressure uint8 (>=0<=12700) mbar True number.mixer_hc1_set_differential_pressure number.mixer_hc1_setdiffpress 7 1 50 6 1
XCUMixer mixer 8 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
XCUMixer mixer 8 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset 7 1 1 8 1
MM10 mixer 69 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
MM10 mixer 69 hc1.valvestatus mixing valve actuator (VC1) int8 (>=-100<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
MM10 mixer 69 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
MM10 mixer 69 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
MM10 mixer 69 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
MM10 mixer 69 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
IPM mixer 100 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
IPM mixer 100 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
IPM mixer 100 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
IPM mixer 100 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
IPM mixer 100 hc1.flowtempvf flow temperature in header (T0/Vf) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) sensor.mixer_hc1_flowtempvf 7 1 1/10 9 1
IPM2 mixer 102 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
IPM2 mixer 102 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
IPM2 mixer 102 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
IPM2 mixer 102 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
IPM2 mixer 102 hc1.flowtempvf flow temperature in header (T0/Vf) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_in_header_(T0/Vf) sensor.mixer_hc1_flowtempvf 7 1 1/10 9 1
MM50 mixer 159 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
MM50 mixer 159 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
MM50 mixer 159 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
MM50 mixer 159 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
MM50 mixer 159 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
MM50 mixer 159 hc1.flow Durchfluss uint16 (>=0<=31999) l/h False sensor.mixer_hc1_Durchfluss sensor.mixer_hc1_flow 7 1 1 5 1
MM50 mixer 159 hc1.setdiffpress set differential pressure uint8 (>=0<=12700) mbar True number.mixer_hc1_set_differential_pressure number.mixer_hc1_setdiffpress 7 1 50 6 1
MM50 mixer 159 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
MM50 mixer 159 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset 7 1 1 8 1
MM100 mixer 160 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
MM100 mixer 160 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
MM100 mixer 160 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
MM100 mixer 160 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
MM100 mixer 160 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
MM100 mixer 160 hc1.flow Durchfluss uint16 (>=0<=31999) l/h False sensor.mixer_hc1_Durchfluss sensor.mixer_hc1_flow 7 1 1 5 1
MM100 mixer 160 hc1.setdiffpress set differential pressure uint8 (>=0<=12700) mbar True number.mixer_hc1_set_differential_pressure number.mixer_hc1_setdiffpress 7 1 50 6 1
MM100 mixer 160 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
MM100 mixer 160 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset 7 1 1 8 1
MM200 mixer 161 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
MM200 mixer 161 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
MM200 mixer 161 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
MM200 mixer 161 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
MM200 mixer 161 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
MM200 mixer 161 hc1.flow Durchfluss uint16 (>=0<=31999) l/h False sensor.mixer_hc1_Durchfluss sensor.mixer_hc1_flow 7 1 1 5 1
MM200 mixer 161 hc1.setdiffpress set differential pressure uint8 (>=0<=12700) mbar True number.mixer_hc1_set_differential_pressure number.mixer_hc1_setdiffpress 7 1 50 6 1
MM200 mixer 161 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
MM200 mixer 161 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset 7 1 1 8 1
MZ100 mixer 193 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
MZ100 mixer 193 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
MZ100 mixer 193 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
MZ100 mixer 193 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
MZ100 mixer 193 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
MZ100 mixer 193 hc1.flow Durchfluss uint16 (>=0<=31999) l/h False sensor.mixer_hc1_Durchfluss sensor.mixer_hc1_flow 7 1 1 5 1
MZ100 mixer 193 hc1.setdiffpress set differential pressure uint8 (>=0<=12700) mbar True number.mixer_hc1_set_differential_pressure number.mixer_hc1_setdiffpress 7 1 50 6 1
MZ100 mixer 193 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
MZ100 mixer 193 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset 7 1 1 8 1
HM210 mixer 248 hc1.flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.mixer_hc1_flow_temperature_(TC1) sensor.mixer_hc1_flowtemphc 7 1 1/10 0 1
HM210 mixer 248 hc1.valvestatus mixing valve actuator (VC1) uint8 (>=0<=100) % False sensor.mixer_hc1_mixing_valve_actuator_(VC1) sensor.mixer_hc1_valvestatus 7 1 1 1 1
HM210 mixer 248 hc1.flowsettemp setpoint flow temperature uint8 (>=0<=254) C True number.mixer_hc1_setpoint_flow_temperature number.mixer_hc1_flowsettemp 7 1 1 2 1
HM210 mixer 248 hc1.pumpstatus pump status (PC1) boolean True switch.mixer_hc1_pump_status_(PC1) switch.mixer_hc1_pumpstatus 7 1 1 3 1
HM210 mixer 248 hc1.activated activated boolean True switch.mixer_hc1_activated switch.mixer_hc1_activated 7 1 1 4 1
HM210 mixer 248 hc1.flow Durchfluss uint16 (>=0<=31999) l/h False sensor.mixer_hc1_Durchfluss sensor.mixer_hc1_flow 7 1 1 5 1
HM210 mixer 248 hc1.setdiffpress set differential pressure uint8 (>=0<=12700) mbar True number.mixer_hc1_set_differential_pressure number.mixer_hc1_setdiffpress 7 1 50 6 1
HM210 mixer 248 hc1.valvesettime time to set valve uint8 (>=10<=600) seconds True number.mixer_hc1_time_to_set_valve number.mixer_hc1_valvesettime 7 1 10 7 1
HM210 mixer 248 hc1.flowtempoffset flow temperature offset for mixer uint8 (>=0<=20) K True number.mixer_hc1_flow_temperature_offset_for_mixer number.mixer_hc1_flowtempoffset 7 1 1 8 1
SM10 solar 73 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp 8 0 1/10 0 1
SM10 solar 73 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp 8 0 1/10 1 1
SM10 solar 73 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump 8 0 1 2 1
SM10 solar 73 pumpworktime pump working time time (>=0<=16777214) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime 8 0 1 3 2
SM10 solar 73 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp 8 0 1 5 1
SM10 solar 73 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown 8 0 1 6 1
SM10 solar 73 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated 8 0 1 7 1
SM10 solar 73 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod 8 0 1 8 1
SM10 solar 73 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod 8 0 1 9 1
SM10 solar 73 turnondiff pump turn on difference uint8 (>=0<=254) C True number.solar_pump_turn_on_difference number.solar_turnondiff 8 0 1 10 1
SM10 solar 73 turnoffdiff pump turn off difference uint8 (>=0<=254) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff 8 0 1 11 1
SM10 solar 73 solarpower actual solar power int16 (>=-31999<=31999) W False sensor.solar_actual_solar_power sensor.solar_solarpower 8 0 1 12 1
SM10 solar 73 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour 8 0 1/10 13 2
SM10 solar 73 maxflow maximum solar flow uint8 (>=0<=25) l/min True number.solar_maximum_solar_flow number.solar_maxflow 8 0 1/10 15 1
SM10 solar 73 dhw.mintemp minimum temperature uint8 (>=0<=254) C True number.solar_dhw_minimum_temperature number.solar_dhw_mintemp 8 9 1 0 1
SM10 solar 73 solarenabled solarmodule enabled boolean True switch.solar_solarmodule_enabled switch.solar_solarenabled 8 0 1 16 1
ISM1 solar 101 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp 8 0 1/10 0 1
ISM1 solar 101 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp 8 0 1/10 1 1
ISM1 solar 101 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump 8 0 1 2 1
ISM1 solar 101 pumpworktime pump working time time (>=0<=16777214) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime 8 0 1 3 2
ISM1 solar 101 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp 8 0 1 5 1
ISM1 solar 101 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown 8 0 1 6 1
ISM1 solar 101 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated 8 0 1 7 1
ISM1 solar 101 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp 8 0 1/10 17 1
ISM1 solar 101 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist 8 0 1/10 18 1
ISM1 solar 101 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve 8 0 1 19 1
ISM1 solar 101 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour 8 0 1/10 13 2
ISM2 solar 103 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp 8 0 1/10 0 1
ISM2 solar 103 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp 8 0 1/10 1 1
ISM2 solar 103 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump 8 0 1 2 1
ISM2 solar 103 pumpworktime pump working time time (>=0<=16777214) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime 8 0 1 3 2
ISM2 solar 103 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp 8 0 1 5 1
ISM2 solar 103 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown 8 0 1 6 1
ISM2 solar 103 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated 8 0 1 7 1
ISM2 solar 103 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp 8 0 1/10 17 1
ISM2 solar 103 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist 8 0 1/10 18 1
ISM2 solar 103 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve 8 0 1 19 1
ISM2 solar 103 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour 8 0 1/10 13 2
SM50 solar 162 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp 8 0 1/10 0 1
SM50 solar 162 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp 8 0 1/10 1 1
SM50 solar 162 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump 8 0 1 2 1
SM50 solar 162 pumpworktime pump working time time (>=0<=16777214) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime 8 0 1 3 2
SM50 solar 162 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp 8 0 1 5 1
SM50 solar 162 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown 8 0 1 6 1
SM50 solar 162 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated 8 0 1 7 1
SM50 solar 162 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod 8 0 1 8 1
SM50 solar 162 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod 8 0 5 9 1
SM50 solar 162 turnondiff pump turn on difference uint8 (>=0<=25) C True number.solar_pump_turn_on_difference number.solar_turnondiff 8 0 1/10 10 1
SM50 solar 162 turnoffdiff pump turn off difference uint8 (>=0<=25) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff 8 0 1/10 11 1
SM50 solar 162 collector2temp collector 2 temperature (TS7) int16 (>=-3199<=3199) C False sensor.solar_collector_2_temperature_(TS7) sensor.solar_collector2temp 8 0 1/10 20 1
SM50 solar 162 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp 8 0 1/10 17 1
SM50 solar 162 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist 8 0 1/10 18 1
SM50 solar 162 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve 8 0 1 19 1
SM50 solar 162 heatassistpower heat assistance valve power (M1) uint8 (>=0<=100) % False sensor.solar_heat_assistance_valve_power_(M1) sensor.solar_heatassistpower 8 0 1 21 1
SM50 solar 162 solarpump2 pump 2 (PS4) boolean False binary_sensor.solar_pump_2_(PS4) binary_sensor.solar_solarpump2 8 0 1 22 1
SM50 solar 162 solarpump2mod pump 2 modulation (PS4) uint8 (>=0<=100) % False sensor.solar_pump_2_modulation_(PS4) sensor.solar_solarpump2mod 8 0 1 23 1
SM50 solar 162 cyl2bottomtemp second cylinder bottom temperature (TS5) int16 (>=-3199<=3199) C False sensor.solar_second_cylinder_bottom_temperature_(TS5) sensor.solar_cyl2bottomtemp 8 0 1/10 24 1
SM50 solar 162 cyl3bottomtemp third cylinder bottom temperature (TS11) int16 (>=-3199<=3199) C False sensor.solar_third_cylinder_bottom_temperature_(TS11) sensor.solar_cyl3bottomtemp 8 0 1/10 25 1
SM50 solar 162 cyltoptemp cylinder top temperature (TS10) int16 (>=-3199<=3199) C False sensor.solar_cylinder_top_temperature_(TS10) sensor.solar_cyltoptemp 8 0 1/10 26 1
SM50 solar 162 heatexchangertemp heat exchanger temperature (TS6) int16 (>=-3199<=3199) C False sensor.solar_heat_exchanger_temperature_(TS6) sensor.solar_heatexchangertemp 8 0 1/10 27 1
SM50 solar 162 cylpumpmod cylinder pump modulation (PS5) uint8 (>=0<=100) % False sensor.solar_cylinder_pump_modulation_(PS5) sensor.solar_cylpumpmod 8 0 1 28 1
SM50 solar 162 valvestatus valve status boolean False binary_sensor.solar_valve_status binary_sensor.solar_valvestatus 8 0 1 29 1
SM50 solar 162 vs1status valve status VS1 boolean False binary_sensor.solar_valve_status_VS1 binary_sensor.solar_vs1status 8 0 1 30 1
SM50 solar 162 vs3status valve status VS3 boolean False binary_sensor.solar_valve_status_VS3 binary_sensor.solar_vs3status 8 0 1 31 1
SM50 solar 162 transferpump transfer pump boolean False binary_sensor.solar_transfer_pump binary_sensor.solar_transferpump 8 0 1 32 1
SM50 solar 162 transferpumpmod transfer pump modulation uint8 (>=0<=100) % False sensor.solar_transfer_pump_modulation sensor.solar_transferpumpmod 8 0 1 33 1
SM50 solar 162 collectormaxtemp maximum collector temperature uint8 (>=0<=254) C True number.solar_maximum_collector_temperature number.solar_collectormaxtemp 8 0 1 34 1
SM50 solar 162 collectormintemp minimum collector temperature uint8 (>=0<=254) C True number.solar_minimum_collector_temperature number.solar_collectormintemp 8 0 1 35 1
SM50 solar 162 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour 8 0 1/10 13 2
SM50 solar 162 energytoday total energy today uint24 (>=0<=16777214) Wh False sensor.solar_total_energy_today sensor.solar_energytoday 8 0 1 36 2
SM50 solar 162 energytotal total energy uint24 (>=0<=1677721) kWh False sensor.solar_total_energy sensor.solar_energytotal 8 0 1/10 38 2
SM50 solar 162 pump2worktime pump 2 working time time (>=0<=16777214) minutes False sensor.solar_pump_2_working_time sensor.solar_pump2worktime 8 0 1 40 2
SM50 solar 162 m1worktime differential control working time time (>=0<=16777214) minutes False sensor.solar_differential_control_working_time sensor.solar_m1worktime 8 0 1 42 2
SM50 solar 162 heattransfersystem heattransfer system boolean True switch.solar_heattransfer_system switch.solar_heattransfersystem 8 0 1 44 1
SM50 solar 162 externalcyl external cylinder boolean True switch.solar_external_cylinder switch.solar_externalcyl 8 0 1 45 1
SM50 solar 162 thermaldisinfect thermal disinfection boolean True switch.solar_thermal_disinfection switch.solar_thermaldisinfect 8 0 1 46 1
SM50 solar 162 heatmetering heatmetering boolean True switch.solar_heatmetering switch.solar_heatmetering 8 0 1 47 1
SM50 solar 162 activated activated boolean True switch.solar_activated switch.solar_activated 8 0 1 48 1
SM50 solar 162 solarpumpmode solar pump mode enum [constant|pwm|analog] True select.solar_solar_pump_mode select.solar_solarpumpmode 8 0 1 49 1
SM50 solar 162 solarpumpkick solar pump kick boolean True switch.solar_solar_pump_kick switch.solar_solarpumpkick 8 0 1 50 1
SM50 solar 162 plainwatermode plain water mode boolean True switch.solar_plain_water_mode switch.solar_plainwatermode 8 0 1 51 1
SM50 solar 162 doublematchflow doublematchflow boolean True switch.solar_doublematchflow switch.solar_doublematchflow 8 0 1 52 1
SM50 solar 162 pump2minmod minimum pump 2 modulation uint8 (>=0<=100) % True number.solar_minimum_pump_2_modulation number.solar_pump2minmod 8 0 1 53 1
SM50 solar 162 turnondiff2 pump 2 turn on difference uint8 (>=0<=25) C True number.solar_pump_2_turn_on_difference number.solar_turnondiff2 8 0 1/10 54 1
SM50 solar 162 turnoffdiff2 pump 2 turn off difference uint8 (>=0<=25) C True number.solar_pump_2_turn_off_difference number.solar_turnoffdiff2 8 0 1/10 55 1
SM50 solar 162 pump2kick pump kick 2 boolean True switch.solar_pump_kick_2 switch.solar_pump2kick 8 0 1 56 1
SM50 solar 162 climatezone climate zone uint8 (>=0<=254) True number.solar_climate_zone number.solar_climatezone 8 0 1 57 1
SM50 solar 162 collector1area collector 1 area uint16 (>=0<=3199) m² True number.solar_collector_1_area number.solar_collector1area 8 0 1/10 58 1
SM50 solar 162 collector1type collector 1 type enum [flat|vacuum] True select.solar_collector_1_type select.solar_collector1type 8 0 1 59 1
SM50 solar 162 collector2area collector 2 area uint16 (>=0<=3199) m² True number.solar_collector_2_area number.solar_collector2area 8 0 1/10 60 1
SM50 solar 162 collector2type collector 2 type enum [flat|vacuum] True select.solar_collector_2_type select.solar_collector2type 8 0 1 61 1
SM50 solar 162 cylpriority cylinder priority enum [cyl 1|cyl 2] True select.solar_cylinder_priority select.solar_cylpriority 8 0 1 62 1
SM50 solar 162 heatcntflowtemp heat counter flow temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_flow_temperature sensor.solar_heatcntflowtemp 8 0 1/10 63 1
SM50 solar 162 heatcntrettemp heat counter return temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_return_temperature sensor.solar_heatcntrettemp 8 0 1/10 64 1
SM50 solar 162 heatcnt heat counter impulses uint8 (>=0<=254) False sensor.solar_heat_counter_impulses sensor.solar_heatcnt 8 0 1 65 1
SM50 solar 162 swapflowtemp swap flow temperature (TS14) uint16 (>=0<=3199) C False sensor.solar_swap_flow_temperature_(TS14) sensor.solar_swapflowtemp 8 0 1/10 66 1
SM50 solar 162 swaprettemp swap return temperature (TS15) uint16 (>=0<=3199) C False sensor.solar_swap_return_temperature_(TS15) sensor.solar_swaprettemp 8 0 1/10 67 1
SM100, MS100 solar 163 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp 8 0 1/10 0 1
SM100, MS100 solar 163 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp 8 0 1/10 1 1
SM100, MS100 solar 163 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump 8 0 1 2 1
SM100, MS100 solar 163 pumpworktime pump working time time (>=0<=16777214) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime 8 0 1 3 2
SM100, MS100 solar 163 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp 8 0 1 5 1
SM100, MS100 solar 163 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown 8 0 1 6 1
SM100, MS100 solar 163 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated 8 0 1 7 1
SM100, MS100 solar 163 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod 8 0 1 8 1
SM100, MS100 solar 163 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod 8 0 5 9 1
SM100, MS100 solar 163 turnondiff pump turn on difference uint8 (>=0<=25) C True number.solar_pump_turn_on_difference number.solar_turnondiff 8 0 1/10 10 1
SM100, MS100 solar 163 turnoffdiff pump turn off difference uint8 (>=0<=25) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff 8 0 1/10 11 1
SM100, MS100 solar 163 collector2temp collector 2 temperature (TS7) int16 (>=-3199<=3199) C False sensor.solar_collector_2_temperature_(TS7) sensor.solar_collector2temp 8 0 1/10 20 1
SM100, MS100 solar 163 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp 8 0 1/10 17 1
SM100, MS100 solar 163 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist 8 0 1/10 18 1
SM100, MS100 solar 163 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve 8 0 1 19 1
SM100, MS100 solar 163 heatassistpower heat assistance valve power (M1) uint8 (>=0<=100) % False sensor.solar_heat_assistance_valve_power_(M1) sensor.solar_heatassistpower 8 0 1 21 1
SM100, MS100 solar 163 solarpump2 pump 2 (PS4) boolean False binary_sensor.solar_pump_2_(PS4) binary_sensor.solar_solarpump2 8 0 1 22 1
SM100, MS100 solar 163 solarpump2mod pump 2 modulation (PS4) uint8 (>=0<=100) % False sensor.solar_pump_2_modulation_(PS4) sensor.solar_solarpump2mod 8 0 1 23 1
SM100, MS100 solar 163 cyl2bottomtemp second cylinder bottom temperature (TS5) int16 (>=-3199<=3199) C False sensor.solar_second_cylinder_bottom_temperature_(TS5) sensor.solar_cyl2bottomtemp 8 0 1/10 24 1
SM100, MS100 solar 163 cyl3bottomtemp third cylinder bottom temperature (TS11) int16 (>=-3199<=3199) C False sensor.solar_third_cylinder_bottom_temperature_(TS11) sensor.solar_cyl3bottomtemp 8 0 1/10 25 1
SM100, MS100 solar 163 cyltoptemp cylinder top temperature (TS10) int16 (>=-3199<=3199) C False sensor.solar_cylinder_top_temperature_(TS10) sensor.solar_cyltoptemp 8 0 1/10 26 1
SM100, MS100 solar 163 heatexchangertemp heat exchanger temperature (TS6) int16 (>=-3199<=3199) C False sensor.solar_heat_exchanger_temperature_(TS6) sensor.solar_heatexchangertemp 8 0 1/10 27 1
SM100, MS100 solar 163 cylpumpmod cylinder pump modulation (PS5) uint8 (>=0<=100) % False sensor.solar_cylinder_pump_modulation_(PS5) sensor.solar_cylpumpmod 8 0 1 28 1
SM100, MS100 solar 163 valvestatus valve status boolean False binary_sensor.solar_valve_status binary_sensor.solar_valvestatus 8 0 1 29 1
SM100, MS100 solar 163 vs1status valve status VS1 boolean False binary_sensor.solar_valve_status_VS1 binary_sensor.solar_vs1status 8 0 1 30 1
SM100, MS100 solar 163 vs3status valve status VS3 boolean False binary_sensor.solar_valve_status_VS3 binary_sensor.solar_vs3status 8 0 1 31 1
SM100, MS100 solar 163 transferpump transfer pump boolean False binary_sensor.solar_transfer_pump binary_sensor.solar_transferpump 8 0 1 32 1
SM100, MS100 solar 163 transferpumpmod transfer pump modulation uint8 (>=0<=100) % False sensor.solar_transfer_pump_modulation sensor.solar_transferpumpmod 8 0 1 33 1
SM100, MS100 solar 163 collectormaxtemp maximum collector temperature uint8 (>=0<=254) C True number.solar_maximum_collector_temperature number.solar_collectormaxtemp 8 0 1 34 1
SM100, MS100 solar 163 collectormintemp minimum collector temperature uint8 (>=0<=254) C True number.solar_minimum_collector_temperature number.solar_collectormintemp 8 0 1 35 1
SM100, MS100 solar 163 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour 8 0 1/10 13 2
SM100, MS100 solar 163 energytoday total energy today uint24 (>=0<=16777214) Wh False sensor.solar_total_energy_today sensor.solar_energytoday 8 0 1 36 2
SM100, MS100 solar 163 energytotal total energy uint24 (>=0<=1677721) kWh False sensor.solar_total_energy sensor.solar_energytotal 8 0 1/10 38 2
SM100, MS100 solar 163 pump2worktime pump 2 working time time (>=0<=16777214) minutes False sensor.solar_pump_2_working_time sensor.solar_pump2worktime 8 0 1 40 2
SM100, MS100 solar 163 m1worktime differential control working time time (>=0<=16777214) minutes False sensor.solar_differential_control_working_time sensor.solar_m1worktime 8 0 1 42 2
SM100, MS100 solar 163 heattransfersystem heattransfer system boolean True switch.solar_heattransfer_system switch.solar_heattransfersystem 8 0 1 44 1
SM100, MS100 solar 163 externalcyl external cylinder boolean True switch.solar_external_cylinder switch.solar_externalcyl 8 0 1 45 1
SM100, MS100 solar 163 thermaldisinfect thermal disinfection boolean True switch.solar_thermal_disinfection switch.solar_thermaldisinfect 8 0 1 46 1
SM100, MS100 solar 163 heatmetering heatmetering boolean True switch.solar_heatmetering switch.solar_heatmetering 8 0 1 47 1
SM100, MS100 solar 163 activated activated boolean True switch.solar_activated switch.solar_activated 8 0 1 48 1
SM100, MS100 solar 163 solarpumpmode solar pump mode enum [constant|pwm|analog] True select.solar_solar_pump_mode select.solar_solarpumpmode 8 0 1 49 1
SM100, MS100 solar 163 solarpumpkick solar pump kick boolean True switch.solar_solar_pump_kick switch.solar_solarpumpkick 8 0 1 50 1
SM100, MS100 solar 163 plainwatermode plain water mode boolean True switch.solar_plain_water_mode switch.solar_plainwatermode 8 0 1 51 1
SM100, MS100 solar 163 doublematchflow doublematchflow boolean True switch.solar_doublematchflow switch.solar_doublematchflow 8 0 1 52 1
SM100, MS100 solar 163 pump2minmod minimum pump 2 modulation uint8 (>=0<=100) % True number.solar_minimum_pump_2_modulation number.solar_pump2minmod 8 0 1 53 1
SM100, MS100 solar 163 turnondiff2 pump 2 turn on difference uint8 (>=0<=25) C True number.solar_pump_2_turn_on_difference number.solar_turnondiff2 8 0 1/10 54 1
SM100, MS100 solar 163 turnoffdiff2 pump 2 turn off difference uint8 (>=0<=25) C True number.solar_pump_2_turn_off_difference number.solar_turnoffdiff2 8 0 1/10 55 1
SM100, MS100 solar 163 pump2kick pump kick 2 boolean True switch.solar_pump_kick_2 switch.solar_pump2kick 8 0 1 56 1
SM100, MS100 solar 163 climatezone climate zone uint8 (>=0<=254) True number.solar_climate_zone number.solar_climatezone 8 0 1 57 1
SM100, MS100 solar 163 collector1area collector 1 area uint16 (>=0<=3199) m² True number.solar_collector_1_area number.solar_collector1area 8 0 1/10 58 1
SM100, MS100 solar 163 collector1type collector 1 type enum [flat|vacuum] True select.solar_collector_1_type select.solar_collector1type 8 0 1 59 1
SM100, MS100 solar 163 collector2area collector 2 area uint16 (>=0<=3199) m² True number.solar_collector_2_area number.solar_collector2area 8 0 1/10 60 1
SM100, MS100 solar 163 collector2type collector 2 type enum [flat|vacuum] True select.solar_collector_2_type select.solar_collector2type 8 0 1 61 1
SM100, MS100 solar 163 cylpriority cylinder priority enum [cyl 1|cyl 2] True select.solar_cylinder_priority select.solar_cylpriority 8 0 1 62 1
SM100, MS100 solar 163 heatcntflowtemp heat counter flow temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_flow_temperature sensor.solar_heatcntflowtemp 8 0 1/10 63 1
SM100, MS100 solar 163 heatcntrettemp heat counter return temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_return_temperature sensor.solar_heatcntrettemp 8 0 1/10 64 1
SM100, MS100 solar 163 heatcnt heat counter impulses uint8 (>=0<=254) False sensor.solar_heat_counter_impulses sensor.solar_heatcnt 8 0 1 65 1
SM100, MS100 solar 163 swapflowtemp swap flow temperature (TS14) uint16 (>=0<=3199) C False sensor.solar_swap_flow_temperature_(TS14) sensor.solar_swapflowtemp 8 0 1/10 66 1
SM100, MS100 solar 163 swaprettemp swap return temperature (TS15) uint16 (>=0<=3199) C False sensor.solar_swap_return_temperature_(TS15) sensor.solar_swaprettemp 8 0 1/10 67 1
SM200, MS200 solar 164 collectortemp collector temperature (TS1) int16 (>=-3199<=3199) C False sensor.solar_collector_temperature_(TS1) sensor.solar_collectortemp 8 0 1/10 0 1
SM200, MS200 solar 164 cylbottomtemp cylinder bottom temperature (TS2) int16 (>=-3199<=3199) C False sensor.solar_cylinder_bottom_temperature_(TS2) sensor.solar_cylbottomtemp 8 0 1/10 1 1
SM200, MS200 solar 164 solarpump pump (PS1) boolean False binary_sensor.solar_pump_(PS1) binary_sensor.solar_solarpump 8 0 1 2 1
SM200, MS200 solar 164 pumpworktime pump working time time (>=0<=16777214) minutes False sensor.solar_pump_working_time sensor.solar_pumpworktime 8 0 1 3 2
SM200, MS200 solar 164 cylmaxtemp maximum cylinder temperature uint8 (>=0<=254) C True number.solar_maximum_cylinder_temperature number.solar_cylmaxtemp 8 0 1 5 1
SM200, MS200 solar 164 collectorshutdown collector shutdown boolean False binary_sensor.solar_collector_shutdown binary_sensor.solar_collectorshutdown 8 0 1 6 1
SM200, MS200 solar 164 cylheated cyl heated boolean False binary_sensor.solar_cyl_heated binary_sensor.solar_cylheated 8 0 1 7 1
SM200, MS200 solar 164 solarpumpmod pump modulation (PS1) uint8 (>=0<=100) % False sensor.solar_pump_modulation_(PS1) sensor.solar_solarpumpmod 8 0 1 8 1
SM200, MS200 solar 164 pumpminmod minimum pump modulation uint8 (>=0<=100) % True number.solar_minimum_pump_modulation number.solar_pumpminmod 8 0 5 9 1
SM200, MS200 solar 164 turnondiff pump turn on difference uint8 (>=0<=25) C True number.solar_pump_turn_on_difference number.solar_turnondiff 8 0 1/10 10 1
SM200, MS200 solar 164 turnoffdiff pump turn off difference uint8 (>=0<=25) C True number.solar_pump_turn_off_difference number.solar_turnoffdiff 8 0 1/10 11 1
SM200, MS200 solar 164 collector2temp collector 2 temperature (TS7) int16 (>=-3199<=3199) C False sensor.solar_collector_2_temperature_(TS7) sensor.solar_collector2temp 8 0 1/10 20 1
SM200, MS200 solar 164 cylmiddletemp cylinder middle temperature (TS3) int16 (>=-3199<=3199) C False sensor.solar_cylinder_middle_temperature_(TS3) sensor.solar_cylmiddletemp 8 0 1/10 17 1
SM200, MS200 solar 164 retheatassist return temperature heat assistance (TS4) int16 (>=-3199<=3199) C False sensor.solar_return_temperature_heat_assistance_(TS4) sensor.solar_retheatassist 8 0 1/10 18 1
SM200, MS200 solar 164 heatassistvalve heat assistance valve (M1) boolean False binary_sensor.solar_heat_assistance_valve_(M1) binary_sensor.solar_heatassistvalve 8 0 1 19 1
SM200, MS200 solar 164 heatassistpower heat assistance valve power (M1) uint8 (>=0<=100) % False sensor.solar_heat_assistance_valve_power_(M1) sensor.solar_heatassistpower 8 0 1 21 1
SM200, MS200 solar 164 solarpump2 pump 2 (PS4) boolean False binary_sensor.solar_pump_2_(PS4) binary_sensor.solar_solarpump2 8 0 1 22 1
SM200, MS200 solar 164 solarpump2mod pump 2 modulation (PS4) uint8 (>=0<=100) % False sensor.solar_pump_2_modulation_(PS4) sensor.solar_solarpump2mod 8 0 1 23 1
SM200, MS200 solar 164 cyl2bottomtemp second cylinder bottom temperature (TS5) int16 (>=-3199<=3199) C False sensor.solar_second_cylinder_bottom_temperature_(TS5) sensor.solar_cyl2bottomtemp 8 0 1/10 24 1
SM200, MS200 solar 164 cyl3bottomtemp third cylinder bottom temperature (TS11) int16 (>=-3199<=3199) C False sensor.solar_third_cylinder_bottom_temperature_(TS11) sensor.solar_cyl3bottomtemp 8 0 1/10 25 1
SM200, MS200 solar 164 cyltoptemp cylinder top temperature (TS10) int16 (>=-3199<=3199) C False sensor.solar_cylinder_top_temperature_(TS10) sensor.solar_cyltoptemp 8 0 1/10 26 1
SM200, MS200 solar 164 heatexchangertemp heat exchanger temperature (TS6) int16 (>=-3199<=3199) C False sensor.solar_heat_exchanger_temperature_(TS6) sensor.solar_heatexchangertemp 8 0 1/10 27 1
SM200, MS200 solar 164 cylpumpmod cylinder pump modulation (PS5) uint8 (>=0<=100) % False sensor.solar_cylinder_pump_modulation_(PS5) sensor.solar_cylpumpmod 8 0 1 28 1
SM200, MS200 solar 164 valvestatus valve status boolean False binary_sensor.solar_valve_status binary_sensor.solar_valvestatus 8 0 1 29 1
SM200, MS200 solar 164 vs1status valve status VS1 boolean False binary_sensor.solar_valve_status_VS1 binary_sensor.solar_vs1status 8 0 1 30 1
SM200, MS200 solar 164 vs3status valve status VS3 boolean False binary_sensor.solar_valve_status_VS3 binary_sensor.solar_vs3status 8 0 1 31 1
SM200, MS200 solar 164 transferpump transfer pump boolean False binary_sensor.solar_transfer_pump binary_sensor.solar_transferpump 8 0 1 32 1
SM200, MS200 solar 164 transferpumpmod transfer pump modulation uint8 (>=0<=100) % False sensor.solar_transfer_pump_modulation sensor.solar_transferpumpmod 8 0 1 33 1
SM200, MS200 solar 164 collectormaxtemp maximum collector temperature uint8 (>=0<=254) C True number.solar_maximum_collector_temperature number.solar_collectormaxtemp 8 0 1 34 1
SM200, MS200 solar 164 collectormintemp minimum collector temperature uint8 (>=0<=254) C True number.solar_minimum_collector_temperature number.solar_collectormintemp 8 0 1 35 1
SM200, MS200 solar 164 energylasthour energy last hour uint24 (>=0<=1677721) Wh False sensor.solar_energy_last_hour sensor.solar_energylasthour 8 0 1/10 13 2
SM200, MS200 solar 164 energytoday total energy today uint24 (>=0<=16777214) Wh False sensor.solar_total_energy_today sensor.solar_energytoday 8 0 1 36 2
SM200, MS200 solar 164 energytotal total energy uint24 (>=0<=1677721) kWh False sensor.solar_total_energy sensor.solar_energytotal 8 0 1/10 38 2
SM200, MS200 solar 164 pump2worktime pump 2 working time time (>=0<=16777214) minutes False sensor.solar_pump_2_working_time sensor.solar_pump2worktime 8 0 1 40 2
SM200, MS200 solar 164 m1worktime differential control working time time (>=0<=16777214) minutes False sensor.solar_differential_control_working_time sensor.solar_m1worktime 8 0 1 42 2
SM200, MS200 solar 164 heattransfersystem heattransfer system boolean True switch.solar_heattransfer_system switch.solar_heattransfersystem 8 0 1 44 1
SM200, MS200 solar 164 externalcyl external cylinder boolean True switch.solar_external_cylinder switch.solar_externalcyl 8 0 1 45 1
SM200, MS200 solar 164 thermaldisinfect thermal disinfection boolean True switch.solar_thermal_disinfection switch.solar_thermaldisinfect 8 0 1 46 1
SM200, MS200 solar 164 heatmetering heatmetering boolean True switch.solar_heatmetering switch.solar_heatmetering 8 0 1 47 1
SM200, MS200 solar 164 activated activated boolean True switch.solar_activated switch.solar_activated 8 0 1 48 1
SM200, MS200 solar 164 solarpumpmode solar pump mode enum [constant|pwm|analog] True select.solar_solar_pump_mode select.solar_solarpumpmode 8 0 1 49 1
SM200, MS200 solar 164 solarpumpkick solar pump kick boolean True switch.solar_solar_pump_kick switch.solar_solarpumpkick 8 0 1 50 1
SM200, MS200 solar 164 plainwatermode plain water mode boolean True switch.solar_plain_water_mode switch.solar_plainwatermode 8 0 1 51 1
SM200, MS200 solar 164 doublematchflow doublematchflow boolean True switch.solar_doublematchflow switch.solar_doublematchflow 8 0 1 52 1
SM200, MS200 solar 164 pump2minmod minimum pump 2 modulation uint8 (>=0<=100) % True number.solar_minimum_pump_2_modulation number.solar_pump2minmod 8 0 1 53 1
SM200, MS200 solar 164 turnondiff2 pump 2 turn on difference uint8 (>=0<=25) C True number.solar_pump_2_turn_on_difference number.solar_turnondiff2 8 0 1/10 54 1
SM200, MS200 solar 164 turnoffdiff2 pump 2 turn off difference uint8 (>=0<=25) C True number.solar_pump_2_turn_off_difference number.solar_turnoffdiff2 8 0 1/10 55 1
SM200, MS200 solar 164 pump2kick pump kick 2 boolean True switch.solar_pump_kick_2 switch.solar_pump2kick 8 0 1 56 1
SM200, MS200 solar 164 climatezone climate zone uint8 (>=0<=254) True number.solar_climate_zone number.solar_climatezone 8 0 1 57 1
SM200, MS200 solar 164 collector1area collector 1 area uint16 (>=0<=3199) m² True number.solar_collector_1_area number.solar_collector1area 8 0 1/10 58 1
SM200, MS200 solar 164 collector1type collector 1 type enum [flat|vacuum] True select.solar_collector_1_type select.solar_collector1type 8 0 1 59 1
SM200, MS200 solar 164 collector2area collector 2 area uint16 (>=0<=3199) m² True number.solar_collector_2_area number.solar_collector2area 8 0 1/10 60 1
SM200, MS200 solar 164 collector2type collector 2 type enum [flat|vacuum] True select.solar_collector_2_type select.solar_collector2type 8 0 1 61 1
SM200, MS200 solar 164 cylpriority cylinder priority enum [cyl 1|cyl 2] True select.solar_cylinder_priority select.solar_cylpriority 8 0 1 62 1
SM200, MS200 solar 164 heatcntflowtemp heat counter flow temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_flow_temperature sensor.solar_heatcntflowtemp 8 0 1/10 63 1
SM200, MS200 solar 164 heatcntrettemp heat counter return temperature uint16 (>=0<=3199) C False sensor.solar_heat_counter_return_temperature sensor.solar_heatcntrettemp 8 0 1/10 64 1
SM200, MS200 solar 164 heatcnt heat counter impulses uint8 (>=0<=254) False sensor.solar_heat_counter_impulses sensor.solar_heatcnt 8 0 1 65 1
SM200, MS200 solar 164 swapflowtemp swap flow temperature (TS14) uint16 (>=0<=3199) C False sensor.solar_swap_flow_temperature_(TS14) sensor.solar_swapflowtemp 8 0 1/10 66 1
SM200, MS200 solar 164 swaprettemp swap return temperature (TS15) uint16 (>=0<=3199) C False sensor.solar_swap_return_temperature_(TS15) sensor.solar_swaprettemp 8 0 1/10 67 1
HP Module heatpump 252 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.heatpump_relative_air_humidity sensor.heatpump_airhumidity 9 0 1 0 1
HP Module heatpump 252 dewtemperature dew point temperature uint8 (>=0<=254) C False sensor.heatpump_dew_point_temperature sensor.heatpump_dewtemperature 9 0 1 1 1
HP Module heatpump 252 curflowtemp current flow temperature int16 (>=-3199<=3199) C False sensor.heatpump_current_flow_temperature sensor.heatpump_curflowtemp 9 0 1/10 2 1
HP Module heatpump 252 rettemp return temperature int16 (>=-3199<=3199) C False sensor.heatpump_return_temperature sensor.heatpump_rettemp 9 0 1/10 3 1
HP Module heatpump 252 sysrettemp system return temperature int16 (>=-3199<=3199) C False sensor.heatpump_system_return_temperature sensor.heatpump_sysrettemp 9 0 1/10 4 1
HP Module heatpump 252 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.heatpump_drain_pan_temp_(TA4) sensor.heatpump_hpta4 9 0 1/10 5 1
HP Module heatpump 252 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_temperature_(TR1) sensor.heatpump_hptr1 9 0 1/10 6 1
HP Module heatpump 252 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.heatpump_hptr3 9 0 1/10 7 1
HP Module heatpump 252 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.heatpump_evaporator_inlet_temperature_(TR4) sensor.heatpump_hptr4 9 0 1/10 8 1
HP Module heatpump 252 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_inlet_temperature_(TR5) sensor.heatpump_hptr5 9 0 1/10 9 1
HP Module heatpump 252 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_outlet_temperature_(TR6) sensor.heatpump_hptr6 9 0 1/10 10 1
HP Module heatpump 252 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.heatpump_air_inlet_temperature_(TL2) sensor.heatpump_hptl2 9 0 1/10 11 1
HP Module heatpump 252 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.heatpump_low_pressure_side_temperature_(PL1) sensor.heatpump_hppl1 9 0 1/10 12 1
HP Module heatpump 252 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.heatpump_high_pressure_side_temperature_(PH1) sensor.heatpump_hpph1 9 0 1/10 13 1
HP Module heatpump 252 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.heatpump_heating_pump_modulation sensor.heatpump_heatingpumpmod 9 0 1 14 1
HP Module heatpump 252 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.heatpump_compressor_speed sensor.heatpump_hpcompspd 9 0 1 15 1
HP Module heatpump 252 hybridstrategy hybrid control strategy enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump preferred|boiler only] True select.heatpump_hybrid_control_strategy select.heatpump_hybridstrategy 9 0 1 16 1
HP Module heatpump 252 lownoisemode low noise mode enum [off|reduced output|switch off hp|perm. reduced] True select.heatpump_low_noise_mode select.heatpump_lownoisemode 9 0 1 17 1
HP Module heatpump 252 lownoisestart low noise starttime uint8 (>=0<=23) hours True number.heatpump_low_noise_starttime number.heatpump_lownoisestart 9 0 1 18 1
HP Module heatpump 252 lownoisestop low noise stoptime uint8 (>=0<=23) hours True number.heatpump_low_noise_stoptime number.heatpump_lownoisestop 9 0 1 19 1
HP Module heatpump 252 dhw.hybriddhw hybrid DHW enum [eco|high comfort] True select.heatpump_dhw_hybrid_DHW select.heatpump_dhw_hybriddhw 9 9 1 0 1
HP Module heatpump 252 energypricegas energy price gas uint8 (>=0<=254) ct/kWh True number.heatpump_energy_price_gas number.heatpump_energypricegas 9 0 1 20 1
HP Module heatpump 252 energypriceel energy price electric uint8 (>=0<=254) ct/kWh True number.heatpump_energy_price_electric number.heatpump_energypriceel 9 0 1 21 1
HP Module heatpump 252 energyfeedpv feed in PV uint8 (>=0<=254) ct/kWh True number.heatpump_feed_in_PV number.heatpump_energyfeedpv 9 0 1 22 1
HP Module heatpump 252 switchovertemp outside switchover temperature int8 (>=-126<=126) C True number.heatpump_outside_switchover_temperature number.heatpump_switchovertemp 9 0 1 23 1
HP Module heatpump 252 airpurgemode air purge mode boolean True switch.heatpump_air_purge_mode switch.heatpump_airpurgemode 9 0 1 24 1
HP Module heatpump 252 heatpumpoutput heatpump output uint8 (>=0<=100) % True number.heatpump_heatpump_output number.heatpump_heatpumpoutput 9 0 1 25 1
HP Module heatpump 252 coolingcircuit cooling circuit boolean True switch.heatpump_cooling_circuit switch.heatpump_coolingcircuit 9 0 1 26 1
HP Module heatpump 252 compstartmod compressor start modulation uint8 (>=0<=100) % True number.heatpump_compressor_start_modulation number.heatpump_compstartmod 9 0 1 27 1
HP Module heatpump 252 heatdrainpan heat drain pan boolean True switch.heatpump_heat_drain_pan switch.heatpump_heatdrainpan 9 0 1 28 1
HP Module heatpump 252 heatcable heating cable boolean True switch.heatpump_heating_cable switch.heatpump_heatcable 9 0 1 29 1
HP Module heatpump 252 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.heatpump_total_energy sensor.heatpump_nrgtotal 9 0 1/100 30 2
HP Module heatpump 252 dhw.nrg energy uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_energy sensor.heatpump_dhw_nrg 9 9 1/100 1 2
HP Module heatpump 252 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.heatpump_energy_heating sensor.heatpump_nrgheat 9 0 1/100 32 2
HP Module heatpump 252 metertotal meter total uint24 (>=0<=167772) kWh False sensor.heatpump_meter_total sensor.heatpump_metertotal 9 0 1/100 34 2
HP Module heatpump 252 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.heatpump_meter_compressor sensor.heatpump_metercomp 9 0 1/100 36 2
HP Module heatpump 252 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.heatpump_meter_e-heater sensor.heatpump_metereheat 9 0 1/100 38 2
HP Module heatpump 252 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.heatpump_meter_heating sensor.heatpump_meterheat 9 0 1/100 40 2
HP Module heatpump 252 dhw.meter meter uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_meter sensor.heatpump_dhw_meter 9 9 1/100 3 2
HP Module heatpump 252 heatingstarts heating control starts uint24 (>=0<=16777214) False sensor.heatpump_heating_control_starts sensor.heatpump_heatingstarts 9 0 1 42 2
HP Module heatpump 252 dhw.startshp starts hp uint24 (>=0<=16777214) False sensor.heatpump_dhw_starts_hp sensor.heatpump_dhw_startshp 9 9 1 5 2
HP Module heatpump 252 fuelheat fuel consumption heating uint32 (>=0<=1677721) kWh False sensor.heatpump_fuel_consumption_heating sensor.heatpump_fuelheat 9 0 1/10 44 2
HP Module heatpump 252 dhw.fueldhw fuel consumption uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_fuel_consumption sensor.heatpump_dhw_fueldhw 9 9 1/10 7 2
HP Module heatpump 252 elheat el. consumption heating uint32 (>=0<=1677721) kWh False sensor.heatpump_el._consumption_heating sensor.heatpump_elheat 9 0 1/10 46 2
HP Module heatpump 252 dhw.eldhw el. consumption uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_el._consumption sensor.heatpump_dhw_eldhw 9 9 1/10 9 2
HP Module heatpump 252 elgenheat el. generation heating uint32 (>=0<=1677721) kWh False sensor.heatpump_el._generation_heating sensor.heatpump_elgenheat 9 0 1/10 48 2
HP Module heatpump 252 dhw.elgendhw el generation uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_el_generation sensor.heatpump_dhw_elgendhw 9 9 1/10 11 2
Hybrid Manager HM200 heatpump 248 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.heatpump_relative_air_humidity sensor.heatpump_airhumidity 9 0 1 0 1
Hybrid Manager HM200 heatpump 248 dewtemperature dew point temperature uint8 (>=0<=254) C False sensor.heatpump_dew_point_temperature sensor.heatpump_dewtemperature 9 0 1 1 1
Hybrid Manager HM200 heatpump 248 curflowtemp current flow temperature int16 (>=-3199<=3199) C False sensor.heatpump_current_flow_temperature sensor.heatpump_curflowtemp 9 0 1/10 2 1
Hybrid Manager HM200 heatpump 248 rettemp return temperature int16 (>=-3199<=3199) C False sensor.heatpump_return_temperature sensor.heatpump_rettemp 9 0 1/10 3 1
Hybrid Manager HM200 heatpump 248 sysrettemp system return temperature int16 (>=-3199<=3199) C False sensor.heatpump_system_return_temperature sensor.heatpump_sysrettemp 9 0 1/10 4 1
Hybrid Manager HM200 heatpump 248 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.heatpump_drain_pan_temp_(TA4) sensor.heatpump_hpta4 9 0 1/10 5 1
Hybrid Manager HM200 heatpump 248 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_temperature_(TR1) sensor.heatpump_hptr1 9 0 1/10 6 1
Hybrid Manager HM200 heatpump 248 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.heatpump_hptr3 9 0 1/10 7 1
Hybrid Manager HM200 heatpump 248 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.heatpump_evaporator_inlet_temperature_(TR4) sensor.heatpump_hptr4 9 0 1/10 8 1
Hybrid Manager HM200 heatpump 248 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_inlet_temperature_(TR5) sensor.heatpump_hptr5 9 0 1/10 9 1
Hybrid Manager HM200 heatpump 248 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_outlet_temperature_(TR6) sensor.heatpump_hptr6 9 0 1/10 10 1
Hybrid Manager HM200 heatpump 248 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.heatpump_air_inlet_temperature_(TL2) sensor.heatpump_hptl2 9 0 1/10 11 1
Hybrid Manager HM200 heatpump 248 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.heatpump_low_pressure_side_temperature_(PL1) sensor.heatpump_hppl1 9 0 1/10 12 1
Hybrid Manager HM200 heatpump 248 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.heatpump_high_pressure_side_temperature_(PH1) sensor.heatpump_hpph1 9 0 1/10 13 1
Hybrid Manager HM200 heatpump 248 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.heatpump_heating_pump_modulation sensor.heatpump_heatingpumpmod 9 0 1 14 1
Hybrid Manager HM200 heatpump 248 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.heatpump_compressor_speed sensor.heatpump_hpcompspd 9 0 1 15 1
Hybrid Manager HM200 heatpump 248 hybridstrategy hybrid control strategy enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump preferred|boiler only] True select.heatpump_hybrid_control_strategy select.heatpump_hybridstrategy 9 0 1 16 1
Hybrid Manager HM200 heatpump 248 lownoisemode low noise mode enum [off|reduced output|switch off hp|perm. reduced] True select.heatpump_low_noise_mode select.heatpump_lownoisemode 9 0 1 17 1
Hybrid Manager HM200 heatpump 248 lownoisestart low noise starttime uint8 (>=0<=23) hours True number.heatpump_low_noise_starttime number.heatpump_lownoisestart 9 0 1 18 1
Hybrid Manager HM200 heatpump 248 lownoisestop low noise stoptime uint8 (>=0<=23) hours True number.heatpump_low_noise_stoptime number.heatpump_lownoisestop 9 0 1 19 1
Hybrid Manager HM200 heatpump 248 dhw.hybriddhw hybrid DHW enum [eco|high comfort] True select.heatpump_dhw_hybrid_DHW select.heatpump_dhw_hybriddhw 9 9 1 0 1
Hybrid Manager HM200 heatpump 248 energypricegas energy price gas uint8 (>=0<=254) ct/kWh True number.heatpump_energy_price_gas number.heatpump_energypricegas 9 0 1 20 1
Hybrid Manager HM200 heatpump 248 energypriceel energy price electric uint8 (>=0<=254) ct/kWh True number.heatpump_energy_price_electric number.heatpump_energypriceel 9 0 1 21 1
Hybrid Manager HM200 heatpump 248 energyfeedpv feed in PV uint8 (>=0<=254) ct/kWh True number.heatpump_feed_in_PV number.heatpump_energyfeedpv 9 0 1 22 1
Hybrid Manager HM200 heatpump 248 switchovertemp outside switchover temperature int8 (>=-126<=126) C True number.heatpump_outside_switchover_temperature number.heatpump_switchovertemp 9 0 1 23 1
Hybrid Manager HM200 heatpump 248 airpurgemode air purge mode boolean True switch.heatpump_air_purge_mode switch.heatpump_airpurgemode 9 0 1 24 1
Hybrid Manager HM200 heatpump 248 heatpumpoutput heatpump output uint8 (>=0<=100) % True number.heatpump_heatpump_output number.heatpump_heatpumpoutput 9 0 1 25 1
Hybrid Manager HM200 heatpump 248 coolingcircuit cooling circuit boolean True switch.heatpump_cooling_circuit switch.heatpump_coolingcircuit 9 0 1 26 1
Hybrid Manager HM200 heatpump 248 compstartmod compressor start modulation uint8 (>=0<=100) % True number.heatpump_compressor_start_modulation number.heatpump_compstartmod 9 0 1 27 1
Hybrid Manager HM200 heatpump 248 heatdrainpan heat drain pan boolean True switch.heatpump_heat_drain_pan switch.heatpump_heatdrainpan 9 0 1 28 1
Hybrid Manager HM200 heatpump 248 heatcable heating cable boolean True switch.heatpump_heating_cable switch.heatpump_heatcable 9 0 1 29 1
Hybrid Manager HM200 heatpump 248 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.heatpump_total_energy sensor.heatpump_nrgtotal 9 0 1/100 30 2
Hybrid Manager HM200 heatpump 248 dhw.nrg energy uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_energy sensor.heatpump_dhw_nrg 9 9 1/100 1 2
Hybrid Manager HM200 heatpump 248 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.heatpump_energy_heating sensor.heatpump_nrgheat 9 0 1/100 32 2
Hybrid Manager HM200 heatpump 248 metertotal meter total uint24 (>=0<=167772) kWh False sensor.heatpump_meter_total sensor.heatpump_metertotal 9 0 1/100 34 2
Hybrid Manager HM200 heatpump 248 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.heatpump_meter_compressor sensor.heatpump_metercomp 9 0 1/100 36 2
Hybrid Manager HM200 heatpump 248 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.heatpump_meter_e-heater sensor.heatpump_metereheat 9 0 1/100 38 2
Hybrid Manager HM200 heatpump 248 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.heatpump_meter_heating sensor.heatpump_meterheat 9 0 1/100 40 2
Hybrid Manager HM200 heatpump 248 dhw.meter meter uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_meter sensor.heatpump_dhw_meter 9 9 1/100 3 2
Hybrid Manager HM200 heatpump 248 heatingstarts heating control starts uint24 (>=0<=16777214) False sensor.heatpump_heating_control_starts sensor.heatpump_heatingstarts 9 0 1 42 2
Hybrid Manager HM200 heatpump 248 dhw.startshp starts hp uint24 (>=0<=16777214) False sensor.heatpump_dhw_starts_hp sensor.heatpump_dhw_startshp 9 9 1 5 2
Hybrid Manager HM200 heatpump 248 fuelheat fuel consumption heating uint32 (>=0<=1677721) kWh False sensor.heatpump_fuel_consumption_heating sensor.heatpump_fuelheat 9 0 1/10 44 2
Hybrid Manager HM200 heatpump 248 dhw.fueldhw fuel consumption uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_fuel_consumption sensor.heatpump_dhw_fueldhw 9 9 1/10 7 2
Hybrid Manager HM200 heatpump 248 elheat el. consumption heating uint32 (>=0<=1677721) kWh False sensor.heatpump_el._consumption_heating sensor.heatpump_elheat 9 0 1/10 46 2
Hybrid Manager HM200 heatpump 248 dhw.eldhw el. consumption uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_el._consumption sensor.heatpump_dhw_eldhw 9 9 1/10 9 2
Hybrid Manager HM200 heatpump 248 elgenheat el. generation heating uint32 (>=0<=1677721) kWh False sensor.heatpump_el._generation_heating sensor.heatpump_elgenheat 9 0 1/10 48 2
Hybrid Manager HM200 heatpump 248 dhw.elgendhw el generation uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_el_generation sensor.heatpump_dhw_elgendhw 9 9 1/10 11 2
CSH5800iG heatpump 16 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.heatpump_relative_air_humidity sensor.heatpump_airhumidity 9 0 1 0 1
CSH5800iG heatpump 16 dewtemperature dew point temperature uint8 (>=0<=254) C False sensor.heatpump_dew_point_temperature sensor.heatpump_dewtemperature 9 0 1 1 1
CSH5800iG heatpump 16 curflowtemp current flow temperature int16 (>=-3199<=3199) C False sensor.heatpump_current_flow_temperature sensor.heatpump_curflowtemp 9 0 1/10 2 1
CSH5800iG heatpump 16 rettemp return temperature int16 (>=-3199<=3199) C False sensor.heatpump_return_temperature sensor.heatpump_rettemp 9 0 1/10 3 1
CSH5800iG heatpump 16 sysrettemp system return temperature int16 (>=-3199<=3199) C False sensor.heatpump_system_return_temperature sensor.heatpump_sysrettemp 9 0 1/10 4 1
CSH5800iG heatpump 16 hpta4 drain pan temp (TA4) int16 (>=-3199<=3199) C False sensor.heatpump_drain_pan_temp_(TA4) sensor.heatpump_hpta4 9 0 1/10 5 1
CSH5800iG heatpump 16 hptr1 compressor temperature (TR1) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_temperature_(TR1) sensor.heatpump_hptr1 9 0 1/10 6 1
CSH5800iG heatpump 16 hptr3 refrigerant temperature liquid side (condenser output) (TR3) int16 (>=-3199<=3199) C False sensor.heatpump_refrigerant_temperature_liquid_side_(condenser_output)_(TR3) sensor.heatpump_hptr3 9 0 1/10 7 1
CSH5800iG heatpump 16 hptr4 evaporator inlet temperature (TR4) int16 (>=-3199<=3199) C False sensor.heatpump_evaporator_inlet_temperature_(TR4) sensor.heatpump_hptr4 9 0 1/10 8 1
CSH5800iG heatpump 16 hptr5 compressor inlet temperature (TR5) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_inlet_temperature_(TR5) sensor.heatpump_hptr5 9 0 1/10 9 1
CSH5800iG heatpump 16 hptr6 compressor outlet temperature (TR6) int16 (>=-3199<=3199) C False sensor.heatpump_compressor_outlet_temperature_(TR6) sensor.heatpump_hptr6 9 0 1/10 10 1
CSH5800iG heatpump 16 hptl2 air inlet temperature (TL2) int16 (>=-3199<=3199) C False sensor.heatpump_air_inlet_temperature_(TL2) sensor.heatpump_hptl2 9 0 1/10 11 1
CSH5800iG heatpump 16 hppl1 low pressure side temperature (PL1) int16 (>=-3199<=3199) C False sensor.heatpump_low_pressure_side_temperature_(PL1) sensor.heatpump_hppl1 9 0 1/10 12 1
CSH5800iG heatpump 16 hpph1 high pressure side temperature (PH1) int16 (>=-3199<=3199) C False sensor.heatpump_high_pressure_side_temperature_(PH1) sensor.heatpump_hpph1 9 0 1/10 13 1
CSH5800iG heatpump 16 heatingpumpmod heating pump modulation uint8 (>=0<=100) % False sensor.heatpump_heating_pump_modulation sensor.heatpump_heatingpumpmod 9 0 1 14 1
CSH5800iG heatpump 16 hpcompspd compressor speed uint8 (>=0<=100) % False sensor.heatpump_compressor_speed sensor.heatpump_hpcompspd 9 0 1 15 1
CSH5800iG heatpump 16 hybridstrategy hybrid control strategy enum [cost optimized|co2 optimized|outside temperature alt.|outside temperature parallel|heatpump preferred|boiler only] True select.heatpump_hybrid_control_strategy select.heatpump_hybridstrategy 9 0 1 16 1
CSH5800iG heatpump 16 lownoisemode low noise mode enum [off|reduced output|switch off hp|perm. reduced] True select.heatpump_low_noise_mode select.heatpump_lownoisemode 9 0 1 17 1
CSH5800iG heatpump 16 lownoisestart low noise starttime uint8 (>=0<=23) hours True number.heatpump_low_noise_starttime number.heatpump_lownoisestart 9 0 1 18 1
CSH5800iG heatpump 16 lownoisestop low noise stoptime uint8 (>=0<=23) hours True number.heatpump_low_noise_stoptime number.heatpump_lownoisestop 9 0 1 19 1
CSH5800iG heatpump 16 dhw.hybriddhw hybrid DHW enum [eco|high comfort] True select.heatpump_dhw_hybrid_DHW select.heatpump_dhw_hybriddhw 9 9 1 0 1
CSH5800iG heatpump 16 energypricegas energy price gas uint8 (>=0<=254) ct/kWh True number.heatpump_energy_price_gas number.heatpump_energypricegas 9 0 1 20 1
CSH5800iG heatpump 16 energypriceel energy price electric uint8 (>=0<=254) ct/kWh True number.heatpump_energy_price_electric number.heatpump_energypriceel 9 0 1 21 1
CSH5800iG heatpump 16 energyfeedpv feed in PV uint8 (>=0<=254) ct/kWh True number.heatpump_feed_in_PV number.heatpump_energyfeedpv 9 0 1 22 1
CSH5800iG heatpump 16 switchovertemp outside switchover temperature int8 (>=-126<=126) C True number.heatpump_outside_switchover_temperature number.heatpump_switchovertemp 9 0 1 23 1
CSH5800iG heatpump 16 airpurgemode air purge mode boolean True switch.heatpump_air_purge_mode switch.heatpump_airpurgemode 9 0 1 24 1
CSH5800iG heatpump 16 heatpumpoutput heatpump output uint8 (>=0<=100) % True number.heatpump_heatpump_output number.heatpump_heatpumpoutput 9 0 1 25 1
CSH5800iG heatpump 16 coolingcircuit cooling circuit boolean True switch.heatpump_cooling_circuit switch.heatpump_coolingcircuit 9 0 1 26 1
CSH5800iG heatpump 16 compstartmod compressor start modulation uint8 (>=0<=100) % True number.heatpump_compressor_start_modulation number.heatpump_compstartmod 9 0 1 27 1
CSH5800iG heatpump 16 heatdrainpan heat drain pan boolean True switch.heatpump_heat_drain_pan switch.heatpump_heatdrainpan 9 0 1 28 1
CSH5800iG heatpump 16 heatcable heating cable boolean True switch.heatpump_heating_cable switch.heatpump_heatcable 9 0 1 29 1
CSH5800iG heatpump 16 nrgtotal total energy uint24 (>=0<=167772) kWh False sensor.heatpump_total_energy sensor.heatpump_nrgtotal 9 0 1/100 30 2
CSH5800iG heatpump 16 dhw.nrg energy uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_energy sensor.heatpump_dhw_nrg 9 9 1/100 1 2
CSH5800iG heatpump 16 nrgheat energy heating uint24 (>=0<=167772) kWh False sensor.heatpump_energy_heating sensor.heatpump_nrgheat 9 0 1/100 32 2
CSH5800iG heatpump 16 metertotal meter total uint24 (>=0<=167772) kWh False sensor.heatpump_meter_total sensor.heatpump_metertotal 9 0 1/100 34 2
CSH5800iG heatpump 16 metercomp meter compressor uint24 (>=0<=167772) kWh False sensor.heatpump_meter_compressor sensor.heatpump_metercomp 9 0 1/100 36 2
CSH5800iG heatpump 16 metereheat meter e-heater uint24 (>=0<=167772) kWh False sensor.heatpump_meter_e-heater sensor.heatpump_metereheat 9 0 1/100 38 2
CSH5800iG heatpump 16 meterheat meter heating uint24 (>=0<=167772) kWh False sensor.heatpump_meter_heating sensor.heatpump_meterheat 9 0 1/100 40 2
CSH5800iG heatpump 16 dhw.meter meter uint24 (>=0<=167772) kWh False sensor.heatpump_dhw_meter sensor.heatpump_dhw_meter 9 9 1/100 3 2
CSH5800iG heatpump 16 heatingstarts heating control starts uint24 (>=0<=16777214) False sensor.heatpump_heating_control_starts sensor.heatpump_heatingstarts 9 0 1 42 2
CSH5800iG heatpump 16 dhw.startshp starts hp uint24 (>=0<=16777214) False sensor.heatpump_dhw_starts_hp sensor.heatpump_dhw_startshp 9 9 1 5 2
CSH5800iG heatpump 16 fuelheat fuel consumption heating uint32 (>=0<=1677721) kWh False sensor.heatpump_fuel_consumption_heating sensor.heatpump_fuelheat 9 0 1/10 44 2
CSH5800iG heatpump 16 dhw.fueldhw fuel consumption uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_fuel_consumption sensor.heatpump_dhw_fueldhw 9 9 1/10 7 2
CSH5800iG heatpump 16 elheat el. consumption heating uint32 (>=0<=1677721) kWh False sensor.heatpump_el._consumption_heating sensor.heatpump_elheat 9 0 1/10 46 2
CSH5800iG heatpump 16 dhw.eldhw el. consumption uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_el._consumption sensor.heatpump_dhw_eldhw 9 9 1/10 9 2
CSH5800iG heatpump 16 elgenheat el. generation heating uint32 (>=0<=1677721) kWh False sensor.heatpump_el._generation_heating sensor.heatpump_elgenheat 9 0 1/10 48 2
CSH5800iG heatpump 16 dhw.elgendhw el generation uint32 (>=0<=1677721) kWh False sensor.heatpump_dhw_el_generation sensor.heatpump_dhw_elgendhw 9 9 1/10 11 2
WM10 switch 71 activated activated boolean False binary_sensor.switch_activated binary_sensor.switch_activated 11 0 1 0 1
WM10 switch 71 flowtemphc flow temperature (TC1) uint16 (>=0<=3199) C False sensor.switch_flow_temperature_(TC1) sensor.switch_flowtemphc 11 0 1/10 1 1
WM10 switch 71 status status int8 (>=-126<=126) False sensor.switch_status sensor.switch_status 11 0 1 2 1
Rego 3000 controller 240 datetime date/time string False sensor.controller_date/time sensor.controller_datetime 12 0 1 0 13
MX400 connect 17 datetime date/time string False sensor.connect_date/time sensor.connect_datetime 13 0 1 0 13
MX400 connect 17 outdoortemp outside temperature int16 (>=-3199<=3199) C False sensor.connect_outside_temperature sensor.connect_outdoortemp 13 0 1/10 13 1
EM10 alert 74 setflowtemp set flow temperature uint8 (>=0<=254) C False sensor.alert_set_flow_temperature sensor.alert_setflowtemp 14 0 1 0 1
EM10 alert 74 setburnpow burner set power uint8 (>=0<=100) % False sensor.alert_burner_set_power sensor.alert_setburnpow 14 0 1 1 1
EM10, EM100 extension 243 flowtempvf flow temperature in header (T0/Vf) int16 (>=-3199<=3199) C False sensor.extension_flow_temperature_in_header_(T0/Vf) sensor.extension_flowtempvf 15 0 1/10 0 1
EM10, EM100 extension 243 input input uint8 (>=0<=25) V False sensor.extension_input sensor.extension_input 15 0 1/10 1 1
EM10, EM100 extension 243 outpow output IO1 uint8 (>=0<=100) % False sensor.extension_output_IO1 sensor.extension_outpow 15 0 1 2 1
EM10, EM100 extension 243 setpower request power uint8 (>=0<=100) % False sensor.extension_request_power sensor.extension_setpower 15 0 1 3 1
EM10, EM100 extension 243 setpoint set temp. uint8 (>=0<=254) C False sensor.extension_set_temp. sensor.extension_setpoint 15 0 1 4 1
EM10, EM100 extension 243 minv min volt. uint8 (>=0<=25) V True number.extension_min_volt. number.extension_minv 15 0 1/10 5 1
EM10, EM100 extension 243 maxv max volt. uint8 (>=0<=25) V True number.extension_max_volt. number.extension_maxv 15 0 1/10 6 1
EM10, EM100 extension 243 mint min temp. uint8 (>=0<=254) C True number.extension_min_temp. number.extension_mint 15 0 1 7 1
EM10, EM100 extension 243 maxt max temp. uint8 (>=0<=254) C True number.extension_max_temp. number.extension_maxt 15 0 1 8 1
EM10, EM100 extension 243 mode operating mode uint8 (>=0<=254) False sensor.extension_operating_mode sensor.extension_mode 15 0 1 9 1
T1RF extension 220 flowtempvf flow temperature in header (T0/Vf) int16 (>=-3199<=3199) C False sensor.extension_flow_temperature_in_header_(T0/Vf) sensor.extension_flowtempvf 15 0 1/10 0 1
T1RF extension 220 input input uint8 (>=0<=25) V False sensor.extension_input sensor.extension_input 15 0 1/10 1 1
T1RF extension 220 outpow output IO1 uint8 (>=0<=100) % False sensor.extension_output_IO1 sensor.extension_outpow 15 0 1 2 1
T1RF extension 220 setpower request power uint8 (>=0<=100) % False sensor.extension_request_power sensor.extension_setpower 15 0 1 3 1
T1RF extension 220 setpoint set temp. uint8 (>=0<=254) C False sensor.extension_set_temp. sensor.extension_setpoint 15 0 1 4 1
T1RF extension 220 minv min volt. uint8 (>=0<=25) V True number.extension_min_volt. number.extension_minv 15 0 1/10 5 1
T1RF extension 220 maxv max volt. uint8 (>=0<=25) V True number.extension_max_volt. number.extension_maxv 15 0 1/10 6 1
T1RF extension 220 mint min temp. uint8 (>=0<=254) C True number.extension_min_temp. number.extension_mint 15 0 1 7 1
T1RF extension 220 maxt max temp. uint8 (>=0<=254) C True number.extension_max_temp. number.extension_maxt 15 0 1 8 1
T1RF extension 220 mode operating mode uint8 (>=0<=254) False sensor.extension_operating_mode sensor.extension_mode 15 0 1 9 1
AM200 heatsource 228 ahs1.sysflowtemp system flow temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_system_flow_temperature sensor.heatsource_ahs1_sysflowtemp 17 19 1/10 0 1
AM200 heatsource 228 ahs1.sysrettemp system return temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_system_return_temperature sensor.heatsource_ahs1_sysrettemp 17 19 1/10 1 1
AM200 heatsource 228 ahs1.altflowtemp alternative hs flow temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_alternative_hs_flow_temperature sensor.heatsource_ahs1_altflowtemp 17 19 1/10 2 1
AM200 heatsource 228 ahs1.altrettemp alternative hs return temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_alternative_hs_return_temperature sensor.heatsource_ahs1_altrettemp 17 19 1/10 3 1
AM200 heatsource 228 ahs1.cyltoptemp cylinder top temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_cylinder_top_temperature sensor.heatsource_ahs1_cyltoptemp 17 19 1/10 4 1
AM200 heatsource 228 ahs1.cylcentertemp cylinder center temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_cylinder_center_temperature sensor.heatsource_ahs1_cylcentertemp 17 19 1/10 5 1
AM200 heatsource 228 ahs1.cylbottomtemp cylinder bottom temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_cylinder_bottom_temperature sensor.heatsource_ahs1_cylbottomtemp 17 19 1/10 6 1
AM200 heatsource 228 ahs1.fluegastemp flue gas temperature int16 (>=-3199<=3199) C False sensor.heatsource_ahs1_flue_gas_temperature sensor.heatsource_ahs1_fluegastemp 17 19 1/10 7 1
AM200 heatsource 228 ahs1.valvebuffer buffer valve uint8 (>=0<=100) % False sensor.heatsource_ahs1_buffer_valve sensor.heatsource_ahs1_valvebuffer 17 19 1 8 1
AM200 heatsource 228 ahs1.valvereturn return valve uint8 (>=0<=100) % False sensor.heatsource_ahs1_return_valve sensor.heatsource_ahs1_valvereturn 17 19 1 9 1
AM200 heatsource 228 ahs1.apumpmod alternative hs pump modulation uint8 (>=0<=100) % False sensor.heatsource_ahs1_alternative_hs_pump_modulation sensor.heatsource_ahs1_apumpmod 17 19 1 10 1
AM200 heatsource 228 ahs1.vr2config vr2 configuration enum [off|bypass] True select.heatsource_ahs1_vr2_configuration select.heatsource_ahs1_vr2config 17 19 1 11 1
AM200 heatsource 228 ahs1.ahsactivated alternate heat source activation boolean True switch.heatsource_ahs1_alternate_heat_source_activation switch.heatsource_ahs1_ahsactivated 17 19 1 12 1
AM200 heatsource 228 ahs1.apumpconfig primary pump config boolean True switch.heatsource_ahs1_primary_pump_config switch.heatsource_ahs1_apumpconfig 17 19 1 13 1
AM200 heatsource 228 ahs1.apumpsignal output for pr1 pump enum [off|pwm|pwm inverse] True select.heatsource_ahs1_output_for_pr1_pump select.heatsource_ahs1_apumpsignal 17 19 1 14 1
AM200 heatsource 228 ahs1.apumpmin min output pump pr1 uint8 (>=12<=50) % True number.heatsource_ahs1_min_output_pump_pr1 number.heatsource_ahs1_apumpmin 17 19 1 15 1
AM200 heatsource 228 ahs1.temprise ahs return temp rise boolean True switch.heatsource_ahs1_ahs_return_temp_rise switch.heatsource_ahs1_temprise 17 19 1 16 1
AM200 heatsource 228 ahs1.setreturntemp set temp return uint8 (>=40<=75) C True number.heatsource_ahs1_set_temp_return number.heatsource_ahs1_setreturntemp 17 19 1 17 1
AM200 heatsource 228 ahs1.mixruntime mixer run time uint16 (>=0<=600) seconds True number.heatsource_ahs1_mixer_run_time number.heatsource_ahs1_mixruntime 17 19 1 18 1
AM200 heatsource 228 ahs1.setflowtemp set flow temperature uint8 (>=40<=75) C True number.heatsource_ahs1_set_flow_temperature number.heatsource_ahs1_setflowtemp 17 19 1 19 1
AM200 heatsource 228 ahs1.bufbypass buffer bypass config enum [no|mixer|valve] True select.heatsource_ahs1_buffer_bypass_config select.heatsource_ahs1_bufbypass 17 19 1 20 1
AM200 heatsource 228 ahs1.bufmixruntime bypass mixer run time uint16 (>=0<=600) seconds True number.heatsource_ahs1_bypass_mixer_run_time number.heatsource_ahs1_bufmixruntime 17 19 1 21 1
AM200 heatsource 228 ahs1.bufconfig dhw buffer config enum [off|monovalent|bivalent] True select.heatsource_ahs1_dhw_buffer_config select.heatsource_ahs1_bufconfig 17 19 1 22 1
AM200 heatsource 228 ahs1.blockmode config htg. blocking mode enum [off|auto|blocking] True select.heatsource_ahs1_config_htg._blocking_mode select.heatsource_ahs1_blockmode 17 19 1 23 1
AM200 heatsource 228 ahs1.blockterm config of block terminal enum [n_o|n_c] True select.heatsource_ahs1_config_of_block_terminal select.heatsource_ahs1_blockterm 17 19 1 24 1
AM200 heatsource 228 ahs1.blockhyst hyst. for boiler block int8 (>=0<=50) C True number.heatsource_ahs1_hyst._for_boiler_block number.heatsource_ahs1_blockhyst 17 19 1 25 1
AM200 heatsource 228 ahs1.releasewait boiler release wait time uint8 (>=0<=240) minutes True number.heatsource_ahs1_boiler_release_wait_time number.heatsource_ahs1_releasewait 17 19 1 26 1
AM200 heatsource 228 ahs1.burner burner boolean False binary_sensor.heatsource_ahs1_burner binary_sensor.heatsource_ahs1_burner 17 19 1 27 1
AM200 heatsource 228 ahs1.apump alternative hs pump boolean False binary_sensor.heatsource_ahs1_alternative_hs_pump binary_sensor.heatsource_ahs1_apump 17 19 1 28 1
AM200 heatsource 228 ahs1.heatrequest heat request uint8 (>=0<=100) % False sensor.heatsource_ahs1_heat_request sensor.heatsource_ahs1_heatrequest 17 19 1 29 1
AM200 heatsource 228 ahs1.blockremain remaining blocktime uint8 (>=0<=254) minutes False sensor.heatsource_ahs1_remaining_blocktime sensor.heatsource_ahs1_blockremain 17 19 1 30 1
AM200 heatsource 228 ahs1.blockremaindhw remaining blocktime dhw uint8 (>=0<=254) minutes False sensor.heatsource_ahs1_remaining_blocktime_dhw sensor.heatsource_ahs1_blockremaindhw 17 19 1 31 1
HRV176, HRV156, 5000c, MV200 ventilation 231 outfresh outdoor fresh air int16 (>=-3199<=3199) C False sensor.ventilation_outdoor_fresh_air sensor.ventilation_outfresh 18 0 1/10 0 1
HRV176, HRV156, 5000c, MV200 ventilation 231 infresh indoor fresh air int16 (>=-3199<=3199) C False sensor.ventilation_indoor_fresh_air sensor.ventilation_infresh 18 0 1/10 1 1
HRV176, HRV156, 5000c, MV200 ventilation 231 outexhaust outdoor exhaust air int16 (>=-3199<=3199) C False sensor.ventilation_outdoor_exhaust_air sensor.ventilation_outexhaust 18 0 1/10 2 1
HRV176, HRV156, 5000c, MV200 ventilation 231 inexhaust indoor exhaust air int16 (>=-3199<=3199) C False sensor.ventilation_indoor_exhaust_air sensor.ventilation_inexhaust 18 0 1/10 3 1
HRV176, HRV156, 5000c, MV200 ventilation 231 ventinspeed in blower speed uint8 (>=0<=100) % False sensor.ventilation_in_blower_speed sensor.ventilation_ventinspeed 18 0 1 4 1
HRV176, HRV156, 5000c, MV200 ventilation 231 ventoutspeed out blower speed uint8 (>=0<=100) % False sensor.ventilation_out_blower_speed sensor.ventilation_ventoutspeed 18 0 1 5 1
HRV176, HRV156, 5000c, MV200 ventilation 231 ventmode ventilation mode enum [auto|off|L1|L2|L3|L4|demand|sleep|intense|bypass|party|fireplace] True select.ventilation_ventilation_mode select.ventilation_ventmode 18 0 1 6 1
HRV176, HRV156, 5000c, MV200 ventilation 231 airquality air quality (voc) uint16 (>=0<=31999) False sensor.ventilation_air_quality_(voc) sensor.ventilation_airquality 18 0 1 7 1
HRV176, HRV156, 5000c, MV200 ventilation 231 airhumidity relative air humidity uint8 (>=0<=100) % False sensor.ventilation_relative_air_humidity sensor.ventilation_airhumidity 18 0 1 8 1
HRV176, HRV156, 5000c, MV200 ventilation 231 bypass bypass boolean True switch.ventilation_bypass switch.ventilation_bypass 18 0 1 9 1
IPM water 100 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.water_dhw_selected_temperature number.water_dhw_seltemp 19 9 1 0 1
IPM water 100 dhw.temp current temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_temperature sensor.water_dhw_temp 19 9 1/10 1 1
IPM water 100 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_extern_temperature sensor.water_dhw_curtemp2 19 9 1/10 2 1
IPM water 100 dhw.hydrTemp hydraulic header temperature uint16 (>=0<=3199) C False sensor.water_dhw_hydraulic_header_temperature sensor.water_dhw_hydrTemp 19 9 1/10 3 1
IPM water 100 dhw.pump pump boolean False binary_sensor.water_dhw_pump binary_sensor.water_dhw_pump 19 9 1 4 1
IPM water 100 dhw.flowtempoffset flow temperature offset uint8 (>=0<=254) C True number.water_dhw_flow_temperature_offset number.water_dhw_flowtempoffset 19 9 1 5 1
IPM water 100 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.water_dhw_hysteresis_on_temperature number.water_dhw_hyston 19 9 1 6 1
IPM water 100 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.water_dhw_hysteresis_off_temperature number.water_dhw_hystoff 19 9 1 7 1
IPM water 100 dhw.disinfectiontemp disinfection temperature uint8 (>=0<=254) C True number.water_dhw_disinfection_temperature number.water_dhw_disinfectiontemp 19 9 1 8 1
IPM water 100 dhw.circ circulation active boolean True switch.water_dhw_circulation_active switch.water_dhw_circ 19 9 1 9 1
IPM water 100 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.water_dhw_circulation_pump_mode select.water_dhw_circmode 19 9 1 10 1
IPM2 water 102 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.water_dhw_selected_temperature number.water_dhw_seltemp 19 9 1 0 1
IPM2 water 102 dhw.temp current temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_temperature sensor.water_dhw_temp 19 9 1/10 1 1
IPM2 water 102 dhw.curtemp2 current extern temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_extern_temperature sensor.water_dhw_curtemp2 19 9 1/10 2 1
IPM2 water 102 dhw.hydrTemp hydraulic header temperature uint16 (>=0<=3199) C False sensor.water_dhw_hydraulic_header_temperature sensor.water_dhw_hydrTemp 19 9 1/10 3 1
IPM2 water 102 dhw.pump pump boolean False binary_sensor.water_dhw_pump binary_sensor.water_dhw_pump 19 9 1 4 1
IPM2 water 102 dhw.flowtempoffset flow temperature offset uint8 (>=0<=254) C True number.water_dhw_flow_temperature_offset number.water_dhw_flowtempoffset 19 9 1 5 1
IPM2 water 102 dhw.hyston hysteresis on temperature int8 (>=-126<=126) C True number.water_dhw_hysteresis_on_temperature number.water_dhw_hyston 19 9 1 6 1
IPM2 water 102 dhw.hystoff hysteresis off temperature int8 (>=-126<=126) C True number.water_dhw_hysteresis_off_temperature number.water_dhw_hystoff 19 9 1 7 1
IPM2 water 102 dhw.disinfectiontemp disinfection temperature uint8 (>=0<=254) C True number.water_dhw_disinfection_temperature number.water_dhw_disinfectiontemp 19 9 1 8 1
IPM2 water 102 dhw.circ circulation active boolean True switch.water_dhw_circulation_active switch.water_dhw_circ 19 9 1 9 1
IPM2 water 102 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.water_dhw_circulation_pump_mode select.water_dhw_circmode 19 9 1 10 1
MM100 water 160 dhw.temp current temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_temperature sensor.water_dhw_temp 19 9 1/10 1 1
MM100 water 160 dhw.tempstatus temperature switch in assigned dhw (MC1) int8 (>=-126<=126) False sensor.water_dhw_temperature_switch_in_assigned_dhw_(MC1) sensor.water_dhw_tempstatus 19 9 1 11 1
MM100 water 160 dhw.pump pump boolean False binary_sensor.water_dhw_pump binary_sensor.water_dhw_pump 19 9 1 4 1
MM100 water 160 dhw.maxtemp maximum temperature uint8 (>=0<=254) C True number.water_dhw_maximum_temperature number.water_dhw_maxtemp 19 9 1 12 1
MM100 water 160 dhw.difftemp start differential temperature int8 (>=-126<=126) C True number.water_dhw_start_differential_temperature number.water_dhw_difftemp 19 9 1 13 1
MM100 water 160 dhw.disinfectiontemp disinfection temperature uint8 (>=0<=254) C True number.water_dhw_disinfection_temperature number.water_dhw_disinfectiontemp 19 9 1 8 1
MM100 water 160 dhw.redtemp reduced temperature uint8 (>=0<=254) C True number.water_dhw_reduced_temperature number.water_dhw_redtemp 19 9 1 14 1
MM100 water 160 dhw.requiredtemp required temperature uint8 (>=0<=254) C True number.water_dhw_required_temperature number.water_dhw_requiredtemp 19 9 1 15 1
MM100 water 160 dhw.circ circulation active boolean True switch.water_dhw_circulation_active switch.water_dhw_circ 19 9 1 9 1
MM100 water 160 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.water_dhw_circulation_pump_mode select.water_dhw_circmode 19 9 1 10 1
MM200 water 161 dhw.temp current temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_temperature sensor.water_dhw_temp 19 9 1/10 1 1
MM200 water 161 dhw.tempstatus temperature switch in assigned dhw (MC1) int8 (>=-126<=126) False sensor.water_dhw_temperature_switch_in_assigned_dhw_(MC1) sensor.water_dhw_tempstatus 19 9 1 11 1
MM200 water 161 dhw.pump pump boolean False binary_sensor.water_dhw_pump binary_sensor.water_dhw_pump 19 9 1 4 1
MM200 water 161 dhw.maxtemp maximum temperature uint8 (>=0<=254) C True number.water_dhw_maximum_temperature number.water_dhw_maxtemp 19 9 1 12 1
MM200 water 161 dhw.difftemp start differential temperature int8 (>=-126<=126) C True number.water_dhw_start_differential_temperature number.water_dhw_difftemp 19 9 1 13 1
MM200 water 161 dhw.disinfectiontemp disinfection temperature uint8 (>=0<=254) C True number.water_dhw_disinfection_temperature number.water_dhw_disinfectiontemp 19 9 1 8 1
MM200 water 161 dhw.redtemp reduced temperature uint8 (>=0<=254) C True number.water_dhw_reduced_temperature number.water_dhw_redtemp 19 9 1 14 1
MM200 water 161 dhw.requiredtemp required temperature uint8 (>=0<=254) C True number.water_dhw_required_temperature number.water_dhw_requiredtemp 19 9 1 15 1
MM200 water 161 dhw.circ circulation active boolean True switch.water_dhw_circulation_active switch.water_dhw_circ 19 9 1 9 1
MM200 water 161 dhw.circmode circulation pump mode enum [off|on|auto|own prog] True select.water_dhw_circulation_pump_mode select.water_dhw_circmode 19 9 1 10 1
SM100, MS100 water 163 dhw.temp current temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_temperature sensor.water_dhw_temp 19 9 1/10 1 1
SM100, MS100 water 163 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.water_dhw_storage_intern_temperature sensor.water_dhw_storagetemp1 19 9 1/10 16 1
SM100, MS100 water 163 dhw.coldtemp cold water uint16 (>=0<=3199) C False sensor.water_dhw_cold_water sensor.water_dhw_coldtemp 19 9 1/10 17 1
SM100, MS100 water 163 dhw.temp5 temperature 5 uint16 (>=0<=3199) C False sensor.water_dhw_temperature_5 sensor.water_dhw_temp5 19 9 1/10 18 1
SM100, MS100 water 163 dhw.rettemp return temperature uint16 (>=0<=3199) C False sensor.water_dhw_return_temperature sensor.water_dhw_rettemp 19 9 1/10 19 1
SM100, MS100 water 163 dhw.pump pump boolean False binary_sensor.water_dhw_pump binary_sensor.water_dhw_pump 19 9 1 4 1
SM100, MS100 water 163 dhw.maxtemp maximum temperature uint8 (>=0<=254) C True number.water_dhw_maximum_temperature number.water_dhw_maxtemp 19 9 1 12 1
SM100, MS100 water 163 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.water_dhw_selected_temperature number.water_dhw_seltemp 19 9 1 0 1
SM100, MS100 water 163 dhw.redtemp reduced temperature uint8 (>=0<=254) C True number.water_dhw_reduced_temperature number.water_dhw_redtemp 19 9 1 14 1
SM100, MS100 water 163 dhw.hottemp extra hot temperature uint8 (>=0<=254) C True number.water_dhw_extra_hot_temperature number.water_dhw_hottemp 19 9 1 20 1
SM100, MS100 water 163 dhw.dailytemp daily temperature uint8 (>=0<=254) C True number.water_dhw_daily_temperature number.water_dhw_dailytemp 19 9 1 21 1
SM100, MS100 water 163 dhw.disinfectiontemp disinfection temperature uint8 (>=0<=254) C True number.water_dhw_disinfection_temperature number.water_dhw_disinfectiontemp 19 9 1 8 1
SM100, MS100 water 163 dhw.circ circulation active boolean True switch.water_dhw_circulation_active switch.water_dhw_circ 19 9 1 9 1
SM100, MS100 water 163 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.water_dhw_circulation_pump_mode select.water_dhw_circmode 19 9 1 10 1
SM100, MS100 water 163 dhw.circtc circulation time controled boolean True switch.water_dhw_circulation_time_controled switch.water_dhw_circtc 19 9 1 22 1
SM100, MS100 water 163 dhw.keepwarm keep warm boolean True switch.water_dhw_keep_warm switch.water_dhw_keepwarm 19 9 1 23 1
SM100, MS100 water 163 dhw.status2 status 2 enum [|||no heat|||heat request||disinfecting|hold] False sensor.water_dhw_status_2 sensor.water_dhw_status2 19 9 1 24 1
SM100, MS100 water 163 dhw.pumpmod pump modulation uint8 (>=0<=100) % False sensor.water_dhw_pump_modulation sensor.water_dhw_pumpmod 19 9 1 25 1
SM100, MS100 water 163 dhw.flow flow rate uint16 (>=0<=3199) l/min False sensor.water_dhw_flow_rate sensor.water_dhw_flow 19 9 1/10 26 1
SM100, MS100 water 163 dhw.valvereturn return valve uint8 (>=0<=100) % True number.water_dhw_return_valve number.water_dhw_valvereturn 19 9 1 27 1
SM100, MS100 water 163 dhw.deltatret temp. diff. return valve uint8 (>=0<=254) K True number.water_dhw_temp._diff._return_valve number.water_dhw_deltatret 19 9 1 28 1
SM100, MS100 water 163 dhw.errordisp error display enum [off|normal|inverted] True select.water_dhw_error_display select.water_dhw_errordisp 19 9 1 29 1
SM200, MS200 water 164 dhw.temp current temperature uint16 (>=0<=3199) C False sensor.water_dhw_current_temperature sensor.water_dhw_temp 19 9 1/10 1 1
SM200, MS200 water 164 dhw.storagetemp1 storage intern temperature uint16 (>=0<=3199) C False sensor.water_dhw_storage_intern_temperature sensor.water_dhw_storagetemp1 19 9 1/10 16 1
SM200, MS200 water 164 dhw.coldtemp cold water uint16 (>=0<=3199) C False sensor.water_dhw_cold_water sensor.water_dhw_coldtemp 19 9 1/10 17 1
SM200, MS200 water 164 dhw.temp5 temperature 5 uint16 (>=0<=3199) C False sensor.water_dhw_temperature_5 sensor.water_dhw_temp5 19 9 1/10 18 1
SM200, MS200 water 164 dhw.rettemp return temperature uint16 (>=0<=3199) C False sensor.water_dhw_return_temperature sensor.water_dhw_rettemp 19 9 1/10 19 1
SM200, MS200 water 164 dhw.pump pump boolean False binary_sensor.water_dhw_pump binary_sensor.water_dhw_pump 19 9 1 4 1
SM200, MS200 water 164 dhw.maxtemp maximum temperature uint8 (>=0<=254) C True number.water_dhw_maximum_temperature number.water_dhw_maxtemp 19 9 1 12 1
SM200, MS200 water 164 dhw.seltemp selected temperature uint8 (>=0<=254) C True number.water_dhw_selected_temperature number.water_dhw_seltemp 19 9 1 0 1
SM200, MS200 water 164 dhw.redtemp reduced temperature uint8 (>=0<=254) C True number.water_dhw_reduced_temperature number.water_dhw_redtemp 19 9 1 14 1
SM200, MS200 water 164 dhw.hottemp extra hot temperature uint8 (>=0<=254) C True number.water_dhw_extra_hot_temperature number.water_dhw_hottemp 19 9 1 20 1
SM200, MS200 water 164 dhw.dailytemp daily temperature uint8 (>=0<=254) C True number.water_dhw_daily_temperature number.water_dhw_dailytemp 19 9 1 21 1
SM200, MS200 water 164 dhw.disinfectiontemp disinfection temperature uint8 (>=0<=254) C True number.water_dhw_disinfection_temperature number.water_dhw_disinfectiontemp 19 9 1 8 1
SM200, MS200 water 164 dhw.circ circulation active boolean True switch.water_dhw_circulation_active switch.water_dhw_circ 19 9 1 9 1
SM200, MS200 water 164 dhw.circmode circulation pump mode enum [off|1x3min|2x3min|3x3min|4x3min|5x3min|6x3min|continuous] True select.water_dhw_circulation_pump_mode select.water_dhw_circmode 19 9 1 10 1
SM200, MS200 water 164 dhw.circtc circulation time controled boolean True switch.water_dhw_circulation_time_controled switch.water_dhw_circtc 19 9 1 22 1
SM200, MS200 water 164 dhw.keepwarm keep warm boolean True switch.water_dhw_keep_warm switch.water_dhw_keepwarm 19 9 1 23 1
SM200, MS200 water 164 dhw.status2 status 2 enum [|||no heat|||heat request||disinfecting|hold] False sensor.water_dhw_status_2 sensor.water_dhw_status2 19 9 1 24 1
SM200, MS200 water 164 dhw.pumpmod pump modulation uint8 (>=0<=100) % False sensor.water_dhw_pump_modulation sensor.water_dhw_pumpmod 19 9 1 25 1
SM200, MS200 water 164 dhw.flow flow rate uint16 (>=0<=3199) l/min False sensor.water_dhw_flow_rate sensor.water_dhw_flow 19 9 1/10 26 1
SM200, MS200 water 164 dhw.valvereturn return valve uint8 (>=0<=100) % True number.water_dhw_return_valve number.water_dhw_valvereturn 19 9 1 27 1
SM200, MS200 water 164 dhw.deltatret temp. diff. return valve uint8 (>=0<=254) K True number.water_dhw_temp._diff._return_valve number.water_dhw_deltatret 19 9 1 28 1
SM200, MS200 water 164 dhw.errordisp error display enum [off|normal|inverted] True select.water_dhw_error_display select.water_dhw_errordisp 19 9 1 29 1
MP100 pool 204 pooltemp pool temperature int16 (>=-3199<=3199) C False sensor.pool_pool_temperature sensor.pool_pooltemp 20 0 1/10 -1 1
MP100 pool 204 poolshuntstatus pool shunt status opening/closing enum [stopped|opening|closing|open|close] False sensor.pool_pool_shunt_status_opening/closing sensor.pool_poolshuntstatus 20 0 1 -1 1
MP100 pool 204 poolshunt pool shunt open/close (0% = pool / 100% = heat) uint8 (>=0<=100) % False sensor.pool_pool_shunt_open/close_(0%=_pool/100%=_heat) sensor.pool_poolshunt 20 0 1 -1 1